Abstract
Purpose
Percutaneous vertebroplasty (PVP) is a common procedure in spine surgery. Bone cement leakage is the most common complication related to this procedure. The purpose of this study was to assess the incidence and risk factors for cement leakage after PVP.
Methods
A total of 485 patients who underwent PVP between August 2003 and August 2013 were enrolled in the study. Clinical and radiological characteristics, including age, gender, diagnosis, operated level, surgical approach, type of anesthesia, volume of bone cement, fracture type, and fracture severity, were considered as potential risk factors. Cement leakage was assessed based on post-operative imaging examination. Six types of leakage were defined and risk factors for each type were analyzed.
Results
The incidence of leakage was 58.2 %. Binary logistic analysis revealed that larger volume of bone cement (P < 0.001) and higher fracture severity grade (P < 0.001) were the strongest independent risk factors. Univariate analysis and multinomial logistic analysis showed that surgical approach (P < 0.001), gender (P = 0.016), and operated level (P = 0.032) were additional risk factors for leakage. Further analysis showed that more bone cement was used in bilateral than unilateral approaches, that men had larger volumes of bone cement injected than women, and that more bone cement was injected into lumbar vertebrae than thoracic vertebrae. Therefore, these risk factors (surgical approach, gender, and operated level) could be attributed to excess bone cement usage.
Conclusions
Cement leakage is very common with PVP. Higher fracture severity grade and larger volume of bone cement were the two strongest independent risk factors for leakage.
Similar content being viewed by others
References
Galibert P, Deramond H, Rosat P, Le Gars D (1987) Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33:166–168
McDonald RJ, Trout AT, Gray LA, Dispenzieri A, Thielen KR, Kallmes DF (2008) Vertebroplasty in multiple myeloma: outcomes in a large patient series. AJNR Am J Neuroradiol 29:642–648
Saracen A, Kotwica Z (2014) Treatment of multiple osteoporotic vertebral compression fractures by percutaneous cement augmentation. Int Orthop 38(11):2309–2312
Chang X, Lv YF, Chen B, Li HY, Han XB, Yang K, Zhang W, Zhou Y, Li CQ (2015) (2015) Vertebroplasty versus kyphoplasty in osteoporotic vertebral compression fracture: a meta-analysis of prospective comparative studies. Int Orthop 39(3):491–500
Dong R, Chen L, Tang T, Gu Y, Luo Z, Shi Q, Li X, Zhou Q, Yang H (2013) Pain reduction following vertebroplasty and kyphoplasty. Int Orthop 37(1):83–87
Lee BJ, Lee SR, Yoo TY (2002) Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report. Spine (Phila Pa 1976) 27:E419–E422
Patel AA, Vaccaro AR, Martyak GG, Harrop JS, Albert TJ, Ludwig SC et al (2007) Neurologic deficit following percutaneous vertebral stabilization. Spine (Phila Pa 1976) 32:1728–1734
Ryu KS, Park CK, Kim MC, Kang JK (2002) Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg 96:56–61
Geraci G, Lo IG, Lo NC, Cannizzaro F, Cajozzo M, Modica G (2013) Asymptomatic bone cement pulmonary embolism after vertebroplasty: case report and literature review. Case Rep Surg 2013:591432
Puri AS, Colen RR, Reddy AS, Groff MW, DiNobile D, Killoran T et al (2011) Lumbar artery pseudoaneurysm after percutaneous vertebroplasty: a unique vascular complication. J Neurosurg Spine 14:296–299
Krueger A, Bliemel C, Zettl R, Ruchholtz S (2009) Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature. Eur Spine J 18:1257–1265
Muijs SP, Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2009) Percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures: evaluation after 36 months. J Bone Joint Surg (Br) 91:379–384
Schmidt R, Cakir B, Mattes T, Wegener M, Puhl W, Richter M (2005) Cement leakage during vertebroplasty: an underestimated problem? Eur Spine J 14:466–473
Genant HK, Wu CY, van Kuijk C, Nevitt MC (1993) Vertebral fracture assessment using a semiquantitative technique. J Bone Miner Res 8:1137–1148
Wang HL, Jiang ZG, Wang ZG, Zhu J, Zhao HT (2009) Analysis of the complication and prevention on treatment of osteoporotic vertebral compressive fractures by percutaneous vertebroplasty (PVP). Zhongguo Gu Shang 22:783–784
Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW (2003) Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg (Br) 85:83–89
Fribourg D, Tang C, Sra P, Delamarter R, Bae H (2004) Incidence of subsequent vertebral fracture after kyphoplasty. Spine (Phila Pa 1976) 29(2270–6):2277
Lee MJ, Dumonski M, Cahill P, Stanley T, Park D, Singh K (2009) Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications. Spine (Phila Pa 1976) 34:1228–1232
Nieuwenhuijse MJ, Bollen L, van Erkel AR, Dijkstra PD (2012) Optimal intravertebral cement volume in percutaneous vertebroplasty for painful osteoporotic vertebral compression fractures. Spine (Phila Pa 1976) 37:1747–1755
Kruger A, Baroud G, Noriega D, Figiel J, Dorschel C, Ruchholtz S et al (2013) Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used. Clin Biomech (Bristol, Avon) 28:725–730
Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2011) Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J 11(9):839–848
Nieuwenhuijse MJ, Muijs SP, van Erkel AR, Dijkstra SP (2010) A clinical comparative study on low versus medium viscosity polymethylmetacrylate bone cement in percutaneous vertebroplasty: viscosity associated with cement leakage. Spine (Phila Pa 1976) 35:E1037–E1044
Limthongkul W, Karaikovic EE, Savage JW, Markovic A (2010) Volumetric analysis of thoracic and lumbar vertebral bodies. Spine J 10:153–158
Baroud G, Crookshank M, Bohner M (2006) High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage. Spine (Phila Pa 1976) 31:2562–2568
Bohner M, Gasser B, Baroud G, Heini P (2003) Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure. Biomaterials 24:2721–2730
Loeffel M, Ferguson SJ, Nolte LP, Kowal JH (2008) Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate. Spine (Phila Pa 1976) 33:1352–1359
Tanigawa N, Komemushi A, Kariya S, Kojima H, Shomura Y, Omura N et al (2007) Relationship between cement distribution pattern and new compression fracture after percutaneous vertebroplasty. AJR Am J Roentgenol 189:W348–W352
Gstottner M, Angerer A, Rosiek R, Bach CM (2012) Quantitative volumetry of cement leakage in viscosity-controlled vertebroplasty. J Spinal Disord Tech 25:E150–E154
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. For this type of study, formal consent is not required.
Additional information
Si-Yuan Zhu and Zhao-Ming Zhong contributed equally to this work.
Rights and permissions
About this article
Cite this article
Zhu, SY., Zhong, ZM., Wu, Q. et al. Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients. International Orthopaedics (SICOT) 40, 1205–1210 (2016). https://doi.org/10.1007/s00264-015-3102-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-015-3102-2