Skip to main content
Log in

Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty?

  • Original Paper
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

Purpose

We report the six year implant survivorship, tibial component alignment and knee and limb function measured by the Oxford Knee Score and Western Ontario and McMaster Universities Osteoarthritis Index ((WOMAC) score after kinematically aligned total knee arthroplasty (TKA) and tested the hypothesis that varus alignment of the tibial component, knee, or limb does not adversely affect implant survival and function.

Methods

We prospectively followed 214 consecutive patients (219 knees) treated with a kinematically aligned TKA in 2007. Kaplan–Meier survival analysis and revision rate per 100 component years determined implant failure. The Oxford Knee Score (0 worst, 48 best) and WOMAC score (0 worst, 100 best) were used to measure function. We categorised tibial component alignment as in-range (≤ 0°) or varus (>0°), knee alignment as in-range (between -2.5° and -7.4°), varus (>-2.5°), or valgus (<-7.4°), and limb alignment as in-range (0° ± 3°), varus (>3°) or valgus (<-3°).

Results

At a mean of 6.3 years (range, 5.8–7.2), implant survivorship was 97.5 % and revision-rate per 100 component years 0.40. Three implants had been revised (deep infection one, loose tibial component one and patella instability [1); two loose patella components were pending revision and considered failures. The average Oxford Knee Score was 43 and WOMAC 91. Function of tibial components (80 %), knees (31 %) and limbs (7 %) that were aligned in varus was similar to patients aligned in-range.

Conclusions

At a mean of 6.3 years after kinematically aligned TKA, varus alignment of the tibial component, knee and limb did not adversely affect implant survival or function, which supports the consideration of kinematic alignment as an alternative to mechanical alignment for performing primary TKA.

Level of evidence, III; therapeutic study.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Maderbacher G, Schaumburger J, Keshmiri A, Barthel M, Springorum HR, Craiovan B, Grifka J, Baier C (2014) Pinless navigation in total knee arthroplasty: Navigation reduced by the maximum? International orthopaedics:1–6. doi:10.1007/s00264-014-2529-1

  2. Iorio R, Mazza D, Drogo P, Bolle G, Conteduca F, Redler A, Valeo L, Conteduca J, Ferretti A (2014) Clinical and radiographic outcomes of an accelerometer-based system for the tibial resection in total knee arthroplasty. International orthopaedics:1–6. doi:10.1007/s00264-014-2541-5

  3. Manzotti A, Cerveri P, Pullen C, Confalonieri N (2014) Computer-assisted unicompartmental knee arthroplasty using dedicated software versus a conventional technique. Int Orthop 38(2):457–463. doi:10.1007/s00264-013-2215-8

    Article  PubMed Central  PubMed  Google Scholar 

  4. Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130(12):1487–1491. doi:10.1007/s00402-010-1064-9

    Article  PubMed  Google Scholar 

  5. Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) the effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 93-A(17):1588–1596

    Google Scholar 

  6. Ritter MA, Davis KE, Davis P, Farris A, Malinzak RA, Berend ME, Meding JB (2013) Preoperative malalignment increases risk of failure after total knee arthroplasty. J Bone Joint Surg Am 95(2):126–131. doi:10.2106/JBJS.K.00607

    Article  PubMed  Google Scholar 

  7. Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg British 73(5):709–714

    CAS  Google Scholar 

  8. Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 92(12):2143–2149. doi:10.2106/JBJS.I.01398

    Article  PubMed  Google Scholar 

  9. Vanlommel L, Vanlommel J, Claes S, Bellemans J (2013) Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc:1–6. doi:10.1007/s00167-013-2481-4

  10. Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471(3):1000–1007. doi:10.1007/s11999-012-2613-z

    Article  PubMed Central  PubMed  Google Scholar 

  11. Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG (2014) A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J 96-B(7):907–913. doi:10.1302/0301-620X.96B7.32812

    Article  CAS  PubMed  Google Scholar 

  12. Howell SM, Papadopoulos S, Kuznik KT, Hull ML (2013) Accurate alignment and high function after kinematically aligned TKA performed with generic instruments. Knee Surg Sports Traumatol Arthrosc 21(10):2271–2280. doi:10.1007/s00167-013-2621-x

    Article  PubMed  Google Scholar 

  13. de Beer J, Petruccelli D, Gandhi R, Winemaker M (2005) Primary total knee arthroplasty in patients receiving workers’ compensation benefits. Can J Surg 48(2):100–105

    PubMed Central  PubMed  Google Scholar 

  14. Howell SM, Hull ML (2012) Principles of kinematic alignment in total knee arthroplasty with and without patient specific cutting blocks (OtisKnee). In: Scott S (ed) Insall and Scott surgery of the knee, vol 1, 5th edn. Elsevier, Philadelphia, pp 1255–1268

    Chapter  Google Scholar 

  15. Howell SM, Kuznik K, Hull ML, Siston RA (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31(9):857–863

    Article  PubMed  Google Scholar 

  16. Nam D, Nunley RM, Barrack RL (2014) Patient dissatisfaction following total knee replacement: a growing concern? Bone Joint J 96-B(11 Supple A):96–100. doi:10.1302/0301-620X.96B11.34152

    Article  CAS  PubMed  Google Scholar 

  17. Howell SM, Hodapp EE, Vernace JV, Hull ML, Meade TD (2012) Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients. Knee Surg Sports Traumatol Arthrosc:1–7. doi:10.1007/s00167-012-2220-2

  18. Howell SM, Kuznik K, Hull ML, Siston RA (2010) Longitudinal shapes of the tibia and femur are unrelated and variable. Clin Orthop Relat Res 468(4):1142–1148. doi:10.1007/s11999-009-0984-6

    Article  PubMed Central  PubMed  Google Scholar 

  19. Nunley R, Ellison B, Zhu J, Ruh E, Howell S, Barrack R (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470(3):895–902. doi:10.1007/s11999-011-2222-2

    Article  PubMed Central  PubMed  Google Scholar 

  20. Dossett H, Swartz G, Estrada N, Lefevre G, Kwasman B (2012) Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics 35(2):160–169

    Google Scholar 

  21. Pearse AJ, Hooper GJ, Rothwell A, Frampton C (2010) Survival and functional outcome after revision of a unicompartmental to a total knee replacement: the New Zealand National Joint Registry. J Bone Joint Surg British 92(4):508–512. doi:10.1302/0301-620X.92B4.22659

    Article  CAS  Google Scholar 

  22. Labek G, Neumann D, Agreiter M, Schuh R, Böhler N (2011) Impact of implant developers on published outcome and reproducibility of cohort-based clinical studies in arthroplasty. J Bone Joint Surg Am 93(Supplement_3):55–61. doi:10.2106/jbjs.k.01108

    Article  PubMed  Google Scholar 

  23. The New Zealand Joint Registry 14 Year Report: January 1999 to December 2012 (2013)

  24. Gu Y, Roth JD, Howell SM, Hull ML (2014) How frequently do four methods for mechanically aligning a total knee arthroplasty cause collateral ligament imbalance and change alignment from normal in white patients? J Bone Joint Surg Am 96(12):e101

    Article  PubMed  Google Scholar 

  25. Delport H, Labey L, Innocenti B, De Corte R, Vander Sloten J, Bellemans J (2014) Restoration of constitutional alignment in TKA leads to more physiological strains in the collateral ligaments. Knee Surg Sports Traumatol Arthrosc:1–11. doi:10.1007/s00167-014-2971-z

  26. Blazek K, Favre J, Asay J, Erhart-Hledik J, Andriacchi T (2014) Age and obesity alter the relationship between femoral articular cartilage thickness and ambulatory loads in individuals without osteoarthritis. J Orthop Res 32(3):394–402. doi:10.1002/jor.22530

    Article  PubMed  Google Scholar 

  27. Williams DP, Blakey CM, Hadfield SG, Murray DW, Price AJ, Field RE (2013) Long-term trends in the Oxford knee score following total knee replacement. Bone Joint J 95-B(1):45–51. doi:10.1302/0301-620X.95B1.28573

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stephen M. Howell.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Howell, S.M., Papadopoulos, S., Kuznik, K. et al. Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty?. International Orthopaedics (SICOT) 39, 2117–2124 (2015). https://doi.org/10.1007/s00264-015-2743-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-015-2743-5

Keywords

Navigation