Abstract
Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.
Similar content being viewed by others
References
Adams CI, Keating JF, Court-Brown CM (2001) Cigarette smoking and open tibial fractures. Injury 32(1):61–65
Blauth M, Bastian L, Krettek C, Knop C, Evans S (2001) Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma 15(3):153–160
Borg T, Larsson S, Lindsjö U (2004) Percutaneous plating of distal tibial fractures. Preliminary results in 21 patients. Injury 35(6):608–614
Borrelli J Jr, Prickett W, Song E, Becker D, Ricci W (2002) Extraosseous blood supply of the tibia and the effects of different plating techniques: a human cadaveric study. J Orthop Trauma 16(10):691–695
Collinge C, Kuper M, Larson K, Protzman R (2007) Minimally invasive plating of high-energy metaphyseal distal tibia fractures. J Orthop Trauma 21(6):355–361
Dickson KF, Montgomery S, Field J (2001) High energy plafond fractures treated by a spanning external fixator initially and followed by a second stage open reduction internal fixation of the articular surface—preliminary report. Injury 32(Suppl 4):SD92–SD98
Digby JM, Holloway GM, Webb JK (1983) A study of function after tibial cast bracing. Injury 14(5):432–439
Fisher WD, Hamblen DL (1978) Problems and pitfalls of compression fixation of long bone fractures: a review of results and complications. Injury 10(2):99–107
Frigg R (2003) Development of the Locking Compression Plate. Injury 34(Suppl 2):B6–B10
Gao H, Zhang CO, Luo CF, Zhou ZB, Zeng BF (2009) Fractures of the distal tibia treated with polyaxial locking plating. Clin Orthop Relat Res 467:831–837
Gullihorn L, Karpman R, Lippiello L (2005) Differential effect of nicotine and smoke condensate on bone cell metabolic activity. J Orthop Trauma 19(1):17–22
Hasenboehler E, Rikli D, Babst R (2007) Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients. Injury 38(3):365–370
Hazarika S, Chakravarthy J, Cooper J (2006) Minimally invasive locking plate osteosynthesis for fractures of the distal tibia—results in 20 patients. Injury 37(9):877–887
Janssen KW, Biert J, van Kampen A (2007) Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 31(5):709–714
Krackhardt T, Dilger J, Flesch I, Höntzsch D, Eingartner C, Weise K (2005) Fractures of the distal tibia treated with closed reduction and minimally invasive plating. Arch Orthop Trauma Surg 125(2):87–94
Moshieff R, Safran O, Segal D, Liebergall M (1999) The unreamed tibial nail in the treatment of distal metaphyseal fractures. Injury 30(2):83–90
Oh CW, Kyung HS, Park IH, Kim PT, Ihn JC (2003) Distal tibial metaphyseal fractures treated by percutaneous plate osteosynthesis. Clin Orthop Relat Res 408:286–291
Olerud C, Molander H (1984) A scoring scaling for symptom evaluation after ankle fracture. Arch Orthop Trauma Surg 103(3):190–194
Ovadia DN, Beals RK (1986) Fractures of the tibial plafond. J Bone Joint Surg Am 68(4):543–551
Pugh KJ, Wolinsky PR, McAndrew MP, Johnson KD (1999) Tibial pilon fractures: a comparison of treatment methods. J Trauma 47(5):937–941
Redfern DJ, Syed SU, Davies SJ (2004) Fractures of the distal tibia: minimally invasive plate osteosynthesis. Injury 35(6):615–620
Rüedi TP, Allgöwer M (1979) The operative treatment of intra-articular fractures of the lower end of the tibia. Clin Orthop Relat Res 138:105–110
Ristiniemi J, Flinkkilä T, Hyvönen P, Lakovaara M, Pakarinen H, Biancari F, Jalovaara P (2007) Two-ring hybrid external fixation of distal tibial fractures: a review of 47 cases. J Trauma 62(1):174–183
Streicher G, Reilmann H (2008) Distal tibial fractures (in German). Unfallchirug 111(11):905–918
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Gupta, R.K., Rohilla, R.K., Sangwan, K. et al. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients. International Orthopaedics (SICOT) 34, 1285–1290 (2010). https://doi.org/10.1007/s00264-009-0880-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-009-0880-4