Skip to main content
Log in

Postmortem imaging exposed: an aid in MR imaging of musculoskeletal structures

  • Review Article
  • Published:
Skeletal Radiology Aims and scope Submit manuscript

Abstract

Objective

To identify factors that influence the quality of postmortem magnetic resonance (MR) images of musculoskeletal (MSK) structures as described in the literature, and to evaluate the extent to which these MR images are affected.

Materials and methods

Four useful studies were retrieved from a PubMed and EMBASE search, covering the literature up to 1 March 2012. Three additional studies were included after a manual search from reference lists.

Results

Four human studies and three animal studies are considered in this review. Postmortem MRI quality can be affected by storage temperature, repeated freezing and thawing and fixation. Provided there was an adequate, but above-freezing storage temperature, postmortem changes in fresh cadavers did not appear to affect the MR image quality of MSK structures up to 14 days after death. Image contrast, signal intensities, and relaxation times are temperature-dependent, regardless of whether the specimen was fresh or postmortem for up to 7 days. Bad image quality can occur owing to accelerated autolysis. Freezing and thawing did not affect image quality, unless repeated too often, or whenever a heating pad was used to speed up the thawing process. Conventional formalin-based fixation leads to swelling of soft tissue and fluid accumulation in joints, and therefore to deteriorated images, with image quality just sufficient to visualize gross anatomy.

Conclusion

Various factors were identified that affect postmortem MR image quality of MSK structures. Postmortem MR image quality was good, except for images of the fixated specimen. Freezing is the preferred method of conservation for specimens that are to be subjected to postmortem MRI.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Dirnhofer R, Jackowski C, Vock P, Potter K, Thali MJ. VIRTOPSY: minimally invasive, imaging-guided virtual autopsy. Radiographics. 2006;26(5):1305–33.

    Article  PubMed  Google Scholar 

  2. Thali MJ, Yen K, Schweitzer W, et al. Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)—a feasibility study. J Forensic Sci. 2003;48(2):386–403.

    PubMed  Google Scholar 

  3. Thali MJ, Jackowski C, Oesterhelweg L, Ross SG, Dirnhofer R. VIRTOPSY—the Swiss virtual autopsy approach. Leg Med (Tokyo). 2007;9(2):100–4.

    Article  Google Scholar 

  4. Roberts IS, Benamore RE, Benbow EW, et al. Post-mortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study. Lancet. 2012;379(9811):136–42.

    Article  PubMed  Google Scholar 

  5. Hodler J, Trudell D, Kang HS, Kjellin I, Resnick D. Inexpensive technique for performing magnetic resonance-pathologic correlation in cadavers. Invest Radiol. 1992;27(4):323–5.

    Article  PubMed  CAS  Google Scholar 

  6. Jutras LC. Magnetic resonance of hearts in a jar: breathing new life into old pathological specimens. Cardiol Young. 2010;20(3):275–83.

    Article  PubMed  Google Scholar 

  7. Persson A, Lindblom M, Jackowski C. A state-of-the-art pipeline for postmortem CT and MRI visualization: from data acquisition to interactive image interpretation at autopsy. Acta Radiol. 2011;52(5):522–36.

    Article  PubMed  Google Scholar 

  8. Petrén-Mallmin M, Ericsson A, Rauschning W, Hemmingson A. The effect of temperature on MR relaxation times and signal intensities for human tissues. Magma. 1993;1:176–84.

    Article  Google Scholar 

  9. Entius CAC, van Rijn RR, Zwamborn AW, Kleinrensink GJ, Robben SGF. Influence of formaldehyde/phenol fixation on MRI of the stifle joint and correlation with plastinated slices. J Int Soc Plast. 2004;19:26–32.

    Google Scholar 

  10. Bolen G, Haye D, Dondelinger R, Busoni V. Magnetic resonance signal changes during time in equine limbs refrigerated at 4 degrees C. Vet Radiol Ultrasound. 2010;51(1):19–24.

    Article  PubMed  Google Scholar 

  11. Widmer WR, Buckwalter KA, Hill MA, Fessler JF, Ivancevich S. A technique for magnetic resonance imaging of equine cadaver specimens. Vet Radiol Ultrasound. 1999;40(1):10–4.

    Article  PubMed  CAS  Google Scholar 

  12. Ruder TD, Hatch GM, Siegenthaler L et al. The influence of body temperature on image contrast in post mortem MRI. Eur J Radiol. 2011;81(6):1366–70.

    Article  PubMed  Google Scholar 

  13. Bolen GE, Haye D, Dondelinger RF, Massart L, Busoni V. Impact of successive freezing-thawing cycles on 3-T magnetic resonance images of the digits of isolated equine limbs. Am J Vet Res. 2011;72(6):780–90.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to thank F. van Etten, clinical librarian at the Academic Medical Center, for her help in data collection. Errors and inconsistencies remain the authors’ own.

Conflict of interest

The authors declare that they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to G. M. M. J. Kerkhoffs.

Rights and permissions

Reprints and permissions

About this article

Cite this article

van der Made, A.D., Maas, M., Beenen, L.F.M. et al. Postmortem imaging exposed: an aid in MR imaging of musculoskeletal structures. Skeletal Radiol 42, 467–472 (2013). https://doi.org/10.1007/s00256-012-1515-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00256-012-1515-1

Keywords

Navigation