Pediatric patient surface doses in neuroangiography

  • Original Article
  • Published:
Pediatric Radiology Aims and scope Submit manuscript

Abstract

Background: Neuroangiographic techniques (diagnostic and interventional) can be lengthy and complex and can be associated with high radiation entrance skin doses from fluoroscopy and digital subtraction angiography (DSA). Objective: To measure entrance surface doses received by pediatric patients undergoing neuroangiographic procedures and to (1) compare these doses with thresholds for deterministic effects, (2) compare these doses with those reported in adults, and (3) to understand the dose relationships among diagnostic and interventional procedures, DSA and fluoroscopy. Materials and methods: A neurobiplane unit with fluoroscopic and DSA capabilities was used for all neuroangiographic procedures. An automated patient dosimeter, installed on both planes of the unit, calculated maximum surface dose. The dosimeter also recorded the number of angiographic frames and the length of fluoroscopy time for each procedure. Results: This retrospective study analyzed entrance surface doses to 100 pediatric patients, 76 of whom underwent neuroangiographic diagnostic procedures and 24 of whom underwent neuroangiographic interventional procedures. The DSA acquisitions ranged from 44 frames to 1,428 frames per procedure and fluoroscopy times ranged from 1.1 to 85.6 min per procedure. The mean surface dose from fluoroscopy was 68.1 mGy (max: 397.1 mGy) in the frontal (PA) plane; in the lateral (LAT) plane, the mean surface dose was 40.9 mGy (max: 418.5 mGy). The mean surface doses from DSA were 263.1 and 126.9 mGy in the frontal and lateral planes, with maximum doses of 924.4 and 410.1 mGy, respectively. Mean fluoroscopy dose rates were 5.4 mGy/min in the PA plane and 4.7 mGy/min in the LAT plane. The DSA largely contributed to the overall procedural surface dose, accounting for 82% of the combined surface dose in the each of the imaging planes. Conclusion: The surface dose for each procedure measured in this study was found to be below thresholds for deterministic effects. Interventional procedures consistently yield the highest doses.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. International Commission on Radiological Protection (1991) Recommendations of the international commission on radiological protection, publication 60. Permagon Press, Oxford

  2. Huda W, Peters KR (1994) Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure. Radiology 193:642–644

    Google Scholar 

  3. Miller DL, Balter S, Cole PE, et al (2003) Radiation doses in interventional radiology procedures: the RAD-IR study. II. Skin dose. J Vasc Interv Radiol 14:977–990

    PubMed  Google Scholar 

  4. Mooney RB, McKinstry CS, Kamel HAM (2000) Absorbed dose and deterministic effects to patients from interventional neuroradiology. Br J Radiol 73:745–751

    CAS  PubMed  Google Scholar 

  5. Norbash A, Busick D, Marks M (1996) Techniques for reducing interventional neuroradiological skin dose; tube position and supplemental beam filtration. AJNR 17:41–49

    CAS  PubMed  Google Scholar 

  6. Theodorakou K, Horrocks JA (2003) A study on radiation doses and irradiated areas in cerebral embolisation. Br J Radiol 76:546–552

    Article  CAS  PubMed  Google Scholar 

  7. U.S. Food and Drug Administration (1995) Clarification: recording information in the medical patient’s record that identifies the potential for serious X-ray induced skin injuries. Center for Devices and Radiological Health

    Google Scholar 

  8. Hansson B, Finnbogason T, Schuwert P, et al (1997) Added copper filtration in digital paediatric double-contrast colon examinations: effects on radiation dose and image quality. Eur Radiol 7:1117–1122

    Article  CAS  PubMed  Google Scholar 

  9. Huda W (2004) Assessment of the problem: pediatric doses in screen-film and digital radiography. Pediatr Radiol [Suppl] 34:S173–S182

    Article  PubMed  Google Scholar 

  10. Morrell RE, Rogers AT, Jobling JC, et al (2004) Barium enema: use of increased copper filtration to optimize dose and image quality. Br J Radiol 77:116–122

    Article  CAS  PubMed  Google Scholar 

  11. Nicholson R, Tuffee F, Uthappa MC (2000) Skin sparing in interventional radiology: the effect of copper filtration. Br J Radiol 73:36–42

    CAS  PubMed  Google Scholar 

  12. Miller DL, Balter S, Wagner LK, et al (2004) Quality improvement guidelines for recording patient radiation dose in the medical record. J Vasc Interv Radiol 15:423–429

    PubMed  Google Scholar 

  13. Cusma JT, Bell MR, Wondrow MA, et al (1999) Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures. J Am Coll Cardiol 33:427–435

    Article  CAS  PubMed  Google Scholar 

  14. O’Dea TJ, Geise RA, Ritenour ER (1999) The potential for radiation-induced skin damage in interventional neuroradiological procedures: a review of 522 cases using automated dosimetry. Med Phys 26:2027–2033

    Article  CAS  PubMed  Google Scholar 

  15. Johns HE, Cunningham JR (1983) The physics of radiology, 4th edn. Charles C. Thomas, Springfield, pp 286–287, 739

  16. Gkanatsios NA, Huda W, Peters KR (2002) Adult patient doses in interventional neuroradiology. Med Phys 29:717–723

    Article  PubMed  Google Scholar 

  17. Kemerink GJ, Frantzen MJ, Oei K, et al (2002) Patient and occupational dose in neurointerventional procedures. Neuroradiology 44:522–528

    Article  CAS  PubMed  Google Scholar 

  18. Koenig TR, Wolff D, Mettler FA, et al (2001) Skin injuries from fluoroscopically guided procedures. 1. Characteristics of radiation injury. AJR 177:13–20

    CAS  PubMed  Google Scholar 

  19. Brenner DJ, Elliston CD, Hall EJ, et al (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT . AJR 176:289–296

    CAS  PubMed  Google Scholar 

  20. Hall EJ (2000) Radiobiology for the radiologist, 5th edn. Lipincott Williams & Wilkins, Philadelphia

    Google Scholar 

  21. Lewall DB, Riley P, Hassoon AA, et al (1995) A fluoroscopy credentialling programme for orthopaedic surgeons. J Bone Joint Surg Br 77:442–444

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bairbre L. Connolly.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Swoboda, N.A., Armstrong, D.G., Smith, J. et al. Pediatric patient surface doses in neuroangiography. Pediatr Radiol 35, 859–866 (2005). https://doi.org/10.1007/s00247-005-1496-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00247-005-1496-5

Keywords

Navigation