Dual X-ray Absorptiometry

Clinical Evaluation of a New Cone-Beam System

  • Published:
Calcified Tissue International Aims and scope Submit manuscript

Abstract

The DMS Lexxos is the first cone-beam dual X-ray absorptiometry (DXA) system capable of performing bone mineral density (BMD) measurements of the spine and hip. By using a two-dimensional (2-D) detector array rather than the linear array used with conventional fan-beam DXA systems, image acquisition time on Lexxos is only 1.5 s. However, the need to correct for the large signal from scattered radiation reaching the detector is a potential source of error in cone-beam DXA. The aim of this clinical evaluation of the Lexxos bone densitometer was to investigate the relative accuracy of cone-beam BMD measurements compared with conventional DXA by performing an in vivo cross-calibration study with an established fan-beam system, the Hologic QDR-4500. Spine (L1–L4) and hip BMD measurements were performed in 135 patients (111 women, 24 men) referred for a bone densitometry examination. Duplicate Lexxos measurements were performed in 27 female patients to evaluate precision. On average, Lexxos spine and femoral neck BMD measurements were 2% lower than those on the QDR-4500, whereas total hip BMD was 5% higher. Larger differences were found for the trochanter and Ward’s triangle regions. For all sites, Lexxos BMD measurements showed a strong linear relationship with those measured on the QDR-4500 with correlation coefficients in the range r = 0.95 to 0.97 for the clinically important spine, femoral neck, and total hip regions. The root mean standard error (RMSE) between Lexxos and QDR-4500 BMDs ranged from 0.037 g/cm2 for the femoral neck to 0.060 g/cm2 for the spine, whereas Lexxos precision was 1.3% for total hip, 2.0% for femoral neck, and 2.3% for spine BMD. Although for the hip BMD sites the RMSE and precision of Lexxos measurements were similar to studies of pencil-beam and fan-beam DXA systems, the results for the spine were poorer than expected. The findings of this study suggest that Lexxos corrects accurately for the effects of scattered radiation at the detector, but that the precision of spine BMD measurements may be limited by involuntary patient movement between the high and low energy X-ray exposures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4

Similar content being viewed by others

References

  1. HK Genant K Engelke T Fuerst C-C Gluer S Grampp ST Harris M Jergas T Lang Y Lu S Majumdar A Mathur M Takada (1996) ArticleTitleNoninvasive assessment of bone mineral and structure: state of the art J Bone Miner Res 11 707–730 Occurrence Handle1:STN:280:BymA28zptlI%3D Occurrence Handle8725168

    CAS  PubMed  Google Scholar 

  2. JA Kanis C-C Glüer (2000) ArticleTitleAn update on the diagnosis and assessment of osteoporosis with densitometry Osteoporos Int 11 192–202 Occurrence Handle10.1007/s001980050281 Occurrence Handle1:STN:280:DC%2BD3c3osVanug%3D%3D Occurrence Handle10824234

    Article  CAS  PubMed  Google Scholar 

  3. B Gullberg O Johnell JA Kanis (1997) ArticleTitleWorld-wide projections for hip fracture Osteoporos Int 7 407–413 Occurrence Handle1:STN:280:DyaK1c%2Fos1Kgtg%3D%3D Occurrence Handle9425497

    CAS  PubMed  Google Scholar 

  4. NF Ray JK Chan M Thamer LJ Melton (1997) ArticleTitleMedical expenditures for the treatment of osteoporotic fractures in the United States in 1995: report from the National Osteoporosis Foundation J Bone Miner Res 12 24–35 Occurrence Handle1:STN:280:ByiA1c3ntl0%3D Occurrence Handle9240722

    CAS  PubMed  Google Scholar 

  5. DM Black SR Cummings DB Karpf JA Cauley DE Thompson MC Nevitt DC Bauer HK Genant WL Haskell R Marcus SM Ott JC Torner SA Quandt TF Reiss KE Ensrud (1996) ArticleTitleRandomised trial of the effect of alendronate on risk of fracture in women with existing vertebral fractures Lancet 348 1535–1541 Occurrence Handle10.1016/S0140-6736(96)07088-2 Occurrence Handle1:CAS:528:DyaK2sXisFCktQ%3D%3D Occurrence Handle8950879

    Article  CAS  PubMed  Google Scholar 

  6. B Ettinger DM Black BH Mitlak RK Knickerbocker T Nickelsen HK Genant C Christiansen PD Delmas JR Zanchetta J Stakkestad CC Gluer K Krueger FJ Cohen S Eckert KE Ensrud LV Avioli P Lips SR Cummings (1999) ArticleTitleReduction of vertebral fracture risk in postmenopausal women with osteoporosis treated with raloxifene: results from a 3-year randomized clinical trial JAMA 282 637–645 Occurrence Handle10.1001/jama.282.7.637 Occurrence Handle1:CAS:528:DyaK1MXlvVKqurg%3D Occurrence Handle10517716

    Article  CAS  PubMed  Google Scholar 

  7. ST Harris NB Watts HK Genant CD McKeever T Hangartner M Keller CH Chesnut J Brown EF Eriksen MS Hoseyni DW Axelrod PD Miller (1999) ArticleTitleEffects of risedronate treatment on vertebral and nonvertebral fractures in women with postmenopausal osteoporosis JAMA 282 1344–1352 Occurrence Handle10.1001/jama.282.14.1344 Occurrence Handle1:CAS:528:DyaK1MXmvFansr0%3D Occurrence Handle10527181

    Article  CAS  PubMed  Google Scholar 

  8. RM Neer CD Arnaud JR Zanchetta R Prince GA Gaich J-Y Reginster AB Hodsman EF Eriksen S Ish-Shalom HK Genant O Wang BH Mitlak (2001) ArticleTitleEffect of recombinant human parathyroid hormone (1-34) fragment on spine and non-spine fractures and bone mineral density in postmenopausal osteoporosis N Engl J Med 344 1434–1441 Occurrence Handle10.1056/NEJM200105103441904 Occurrence Handle1:CAS:528:DC%2BD3MXktVSgsbw%3D Occurrence Handle11346808

    Article  CAS  PubMed  Google Scholar 

  9. WHO Technical Report Series 843. (1994) Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. World Health Organization, Geneva

  10. Royal College of Physicians (2000) Osteoporosis: clinical guidelines for prevention and treatment. Update on pharmacological interventions and an algorithm for management. RCP, London, England

  11. ID Cullum PJ Ell JP Ryder (1989) ArticleTitleX-ray dual photon absorptiometry: a new method for the measurement of bone density Br J Radiol 62 587–592 Occurrence Handle1:STN:280:BiaA3snjtlY%3D Occurrence Handle2758245

    CAS  PubMed  Google Scholar 

  12. RB Mazess B Collick J Trempe HS Barden JA Hanson (1989) ArticleTitlePerformance evaluation of a dual-energy X-ray bone densitometer Calcif Tissue Int 44 228–232 Occurrence Handle1:STN:280:BiaC2M7gvF0%3D Occurrence Handle2493329

    CAS  PubMed  Google Scholar 

  13. SE Bouyoucef ID Cullum PJ Ell (1996) ArticleTitleCross-calibration of a fan-beam X-ray densitometer with a pencil-beam system Br J Radiol 69 522–531 Occurrence Handle1:STN:280:BymA3MfhvVE%3D Occurrence Handle8757654

    CAS  PubMed  Google Scholar 

  14. RB Mazess JA Hanson R Payne R Nord M Wilson (2000) ArticleTitleAxial and total-body bone densitometry using a narrow-angle fan-beam Osteoporos Int 11 158–166 Occurrence Handle1:STN:280:DC%2BD3c3lsVentw%3D%3D Occurrence Handle10793875

    CAS  PubMed  Google Scholar 

  15. JM Dinten C Robert-Coutant M Darboux (2001) ArticleTitleDual-energy X-ray absorptiometry using a 2D digital radiography detector: application to bone densitometry Proc SPIE 4320 459–468 Occurrence Handlefull_text||10.1117/12.430945

    Article  Google Scholar 

  16. JN Fordham DJ Chinn N Kumar (2000) ArticleTitleIdentification of women with reduced bone density at the lumbar spine and femoral neck using BMD at the os calcis Osteoporos Int 11 797–802 Occurrence Handle10.1007/s001980070059 Occurrence Handle1:STN:280:DC%2BD3M7hs1aquw%3D%3D Occurrence Handle11148807

    Article  CAS  PubMed  Google Scholar 

  17. ML Bouxsein DA Michaeli DB Plass DA Schick ME Melton (1997) ArticleTitlePrecision and accuracy of computed digital absorptiometry for assessment of bone density of the hand Osteoporos Int 7 444–449 Occurrence Handle10.1007/s001980050031 Occurrence Handle1:STN:280:DyaK1c%2Fos1Kguw%3D%3D Occurrence Handle9425502

    Article  CAS  PubMed  Google Scholar 

  18. V Boudousq PO Kotzki JM Dinten C Barrau C Robert-Coutant E Thomas D Mariano Goulart (2003) ArticleTitleTotal dose incurred by patients and staff from BMD measurement using a new 2D digital bone densitometer Osteoporos Int 14 263–269 Occurrence Handle1:STN:280:DC%2BD3s3ksFemtQ%3D%3D Occurrence Handle12730787

    CAS  PubMed  Google Scholar 

  19. HK Genant S Grampp C-C Glüer KG Faulkner M Jergas K Engelke S Hagiwara C Kuijk ParticleVan (1994) ArticleTitleUniversal standardization for dual X-ray absorptiometry: patient and phantom cross-calibration results J Bone Miner Res 9 1503–1514 Occurrence Handle1:STN:280:ByqC3MjlsFY%3D Occurrence Handle7817795

    CAS  PubMed  Google Scholar 

  20. R Patel GM Blake J Rymer I Fogelman (2000) ArticleTitleLong-term precision of DXA scanning assessed over seven years in forty postmenopausal women Osteoporos Int 11 68–75 Occurrence Handle10.1007/s001980050008 Occurrence Handle1:STN:280:DC%2BD3c7ivFKqtA%3D%3D Occurrence Handle10663361

    Article  CAS  PubMed  Google Scholar 

  21. DG Altman (1991) Practical statistics for medical research Chapman Hall London

    Google Scholar 

  22. KG Faulkner C-C Gluer MJ Estilo HK Genant (1993) ArticleTitleCross-calibration of DXA equipment: upgrading from a Hologic QDR-1000/W to a QDR-2000 Calcif Tissue Int 52 79–84 Occurrence Handle10.1007/BF00308312 Occurrence Handle1:STN:280:ByyC1cvovFQ%3D Occurrence Handle8443695

    Article  CAS  PubMed  Google Scholar 

  23. C-C Gluer G Blake Y Lu BA Blunt M Jergas HK Genant (1995) ArticleTitleAccurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques Osteoporos Int 5 262–270 Occurrence Handle1:STN:280:BymD2MzhtVI%3D Occurrence Handle7492865

    CAS  PubMed  Google Scholar 

  24. AC Looker HW Wahner WL Dunn MS Calvo TB Harris SP Heyse CC Johnston R Lindsay (1998) ArticleTitleUpdated data on proximal femur bone mineral levels of US adults Osteoporos Int 8 468–489 Occurrence Handle10.1007/s001980050093 Occurrence Handle1:STN:280:DyaK1M%2FmslensA%3D%3D Occurrence Handle9850356

    Article  CAS  PubMed  Google Scholar 

  25. GM Blake JC Parker FMA Buxton I Fogelman (1993) ArticleTitleDual X-ray absorptiometry: a comparison between fan beam and pencil beam scans Br J Radiol 66 902–906 Occurrence Handle1:STN:280:ByuD3srpvFQ%3D Occurrence Handle8220974

    CAS  PubMed  Google Scholar 

  26. GM Blake EJ Harrison JE Adams (2004) ArticleTitleDual X-ray absorptiometry: cross-calibration of a new fan-beam system Calcif Tissue Int 75 7–14 Occurrence Handle10.1007/s00223-004-0169-y Occurrence Handle1:CAS:528:DC%2BD2cXmsVCmsrw%3D Occurrence Handle15037973

    Article  CAS  PubMed  Google Scholar 

  27. KM Knapp GM Blake TD Spector I Fogelman (2004) ArticleTitleCan the WHO definition of osteoporosis be applied to multi-site axial transmission quantitative ultrasound? Osteoporos Int 15 367–374 Occurrence Handle10.1007/s00198-003-1555-4 Occurrence Handle1:STN:280:DC%2BD2c3gsFKhtg%3D%3D Occurrence Handle14685652

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors wish to thank CML for the opportunity to evaluate the Lexxos DXA system and the DMS engineers for technical support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to G. M. Blake.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Blake, G.M., Knapp, K.M. & Fogelman, I. Dual X-ray Absorptiometry. Calcif Tissue Int 76, 113–120 (2005). https://doi.org/10.1007/s00223-004-0080-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00223-004-0080-6

Keywords

Navigation