Abstract
The fragility fracture discriminative ability of radius quantitative ultrasound (QUS) was evaluated in a systematic review of 13 studies, including 16,681 individuals and 1296 fractures. The radial speed of sound (SOS) per standard deviation (SD) decrease contributed to an increased risk of total and hip fracture by 32% and 66% in women. Osteoporotic fracture, as a devastating consequence of osteoporosis, brings severe socio-economic burden. The availability of dual-energy X-ray absorptiometry (DXA), as the gold standard of diagnosis, was quite limited in remote areas. Radius QUS measured by SOS shows potential in fracture discriminative ability where DXA equipment is not available. This study aimed to provide a comprehensive evaluation of the association between radius QUS and fracture risk. A detailed article search was carried out on PubMed, EMBASE, Cochrane Libraries, CNKI, Wan-Fang database, VIP, and SinoMed for studies published between January 1980 and February 2020. We determined the estimated relative risk (RR) for fracture per each radial SOS SD decrease. A meta-analysis of studies was performed under the random-effects model. A total of 16,681 individuals were included in this review. Among the participants, 5892 were male and 10,789 were female. A total of 1296 cases of fragility fracture were included. With each SD decrease in radial SOS, the risk of overall fragility fracture and hip fracture was increased by 21% and 55%, respectively. Particularly, the risk was increased by 32% and 66% for women. The association was even stronger for postmenopausal women. Radius QUS showed great potential as an effective tool for fracture risk evaluation, especially for women.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Osteoporosis is a progressive, systemic skeletal disorder characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture [1]. Osteoporotic fractures or fragility fractures, predominantly at the hip, spine, and wrist, are responsible for a higher disease burden, in terms of disability and excess mortality, than some common cancers. The number of new fractures in 2010 in the European Union was estimated at 3.5 million. And the number of deaths related to fractures was estimated at 43,000 [2]. The incidence rate of fracture was 249 per 10,000 person years over 50 years old in 2011 in a Danish study [3]. The prevalence of osteoporosis is 10.75% in postmenopausal women and 4.29% in men over 50 years old in China [4]. Worse, the incidence rate of hip fracture has already risen by more than 2- to 3-fold in most Asian countries [5]. Osteoporosis increases the risk of fragility fracture. Fragility fracture not only impairs life quality but also increases healthcare costs [2]. It has been estimated that hip fractures reduce life expectancy by 25% compared with the general population [6]. With the extension of average life expectancy, the osteoporotic fracture has been a trouble for public health and bring huge social and economic burden. It is well acknowledged that osteoporosis screening in the community represents a highly cost-effective intervention [7].
Many fracture risk assessment tools were applied in the case of fragility prevention. Dual-energy X-ray absorptiometry (DXA) is the current gold standard for the diagnosis of osteoporosis, providing bone mineral density (BMD). According to the World Health Organization (WHO) statement, osteoporosis is present if the axial or distal radial BMD reading is − 2.5 SD below young adult average, typically reported as T-score. DXA is the gold standard for the diagnosis of osteoporosis, as well as a powerful tool to evaluate fracture risk [8]. The Fracture Risk Assessment Tool (FRAX), proposed by the WHO, is widely used for calculating the 10-year absolute risk of hip fracture and major osteoporotic fracture. Based on the clinical risk factors and BMD of the femoral neck, an intact evaluation of FRAX is inseparable with DXA. However, the number of diagnostic DXA scanners in Asia per million population is less than 0.35, according to the Asian audit from the International Osteoporosis Foundation [5]. And most of these DXA scanners are owned by tertiary medical institutions, due to its high costs, large size, and ionizing radiation. As a consequence, DXA is not an optimal technique for osteoporosis screening and fracture risk evaluation at primary health care. There were also some limitations of the FRAX tool, such as lacking dose and duration of the glucocorticoid, number/location/type of fractures, smoking, and alcohol consumption [9]. Due to a lack of proper fracture risk evaluation tools, a large number of individuals with a high risk of fragility fracture in the community can neither be discriminated against nor be given proper treatment.
QUS was first proposed in 1984 by Langton et al. [10, 11]. And QUS has been widely used not only in osteoporosis screening but also in fracture risk evaluation [12, 13]. The ultrasound technique is a simple, versatile, and potential method for predicting high fracture risk in primary health care. SOS and broadband ultrasound attenuation (BUA) are two pivotal parameters of the QUS. Besides, QUS offers additional information about cortical and trabecular microstructure that is independent of BMD and reduces radiation exposure [14, 15]. Clinical use of the QUS in the diagnosis of osteoporosis is limited, because of lacking appropriate diagnostic criteria [16]. Trimpou et al. reported that calcaneus QUS only had a sensitivity of 79% and specificity of 45% comparing with DXA, and showed quite restricted diagnostic efficacy [17]. Despite the limitation in osteoporosis diagnosis, the role of QUS in fracture risk assessment cannot be ignored. In the later period, QUS technology has achieved great progress. Multisite QUS has been disseminated worldwide. The common measurement sites include the calcaneus, radius, and phalanx. Radius QUS, as SOS measured, is a potential alternative in geographies where DXA equipment is not available. Radius QUS is considered a valid approach in primary health cares for fractures risk assessment and osteoporosis prescreening [18,19,20,21]. But some researchers found out that peripheral QUS was not a satisfactory method [22,23,24]. At present, it is still controversial if the QUS measured at radius could discriminate the fractured subjects from the nonfractured one or predict the high fracture risk.
Up to date, there is no review or meta-analysis concerning the fracture discriminative ability of radius QUS. Therefore, we aimed to evaluate the fracture discrimination of radius QUS by receiving current literature and summarizing the research status.
Materials and methods
Search strategy and study selection
A systemic search was conducted for articles on PubMed (US National Library of Medicine), EMBASE, Cochrane Libraries, CNKI (China national knowledge internet), Wan-Fang database, VIP (China Science and Technology Journal Database), and SinoMed (China biomedical literature service system). It was required that each literature was published between January 1980 and February 2020, and specific search strategy is listed below: 1# osteoporosis [MeSH term] 2# quantitative ultrasound [Title/Abstract] 3# radius [all fields] 4# 1 and 2 and 3. Cross-references of the included studies were also searched for any further studies that could be included. Two authors (FY, LCC) independently searched the literature and jointly screened abstracts of the studies. The included studies were fulfilled following criteria: (1) radius QUS had been used to fracture discrimination; (2) radius QUS parameter was SOS and measurement site was distal radius; (3) studies gave a RR or related measures such as the odds ratio (OR), the hazard ratio (HR), and its 95% confidence interval (CI) for fractures to describe the ability of fracture discrimination; (4) studies included more than 20 individuals. Furthermore, only human studies published in English or Chinese literature were included. Studies were excluded if they (a) included the fracture caused by major trauma; (b) focused on cadaver bone or any animal experimental research; (c) had incomplete, missing, or overlapped data; (d) were case reports, conference proceeding, editorial comments, and letters to the editor which do not contain the original data and whose full text cannot be accessed; (e) were not in English or Chinese. With these criteria, 13 studies were identified and included (Fig. 1).
Data extraction and quality assessment
The following items were extracted from each study: the name of the first author, year of publication, country or region, study design (duration of follow-up time would be extracted if cohort study was included), the sample sizes, participants’ characteristics, QUS devices, and adjusted confounders. RR or related measures (OR, HR) and its 95%CI for fractures discrimination were extracted from each study. The methodological quality of the studies was assessed according to the Newcastle-Ottawa Scale (NOS) [25]. All studies were judged on three perspectives: selection, comparability, and outcome or exposure for case-control or cohort studies respectively [26]. The overall quality was critically appraised by 2 authors independently. Discrepancies between the researchers were resolved by discussion.
Statistical analysis
All data were imported into Excel 2019 (Microsoft Corporation, Redmond, CA). The statistical analyses were conducted using R version 3.6.1. We used the adjusted RR, HR, or OR and its 95%CI in all analyses. In our meta-analysis, ORs and HRs were directly considered as RRs. To identify and quantify the between-study heterogeneity, the Cochrane Q test and I2 are applied [27]. When I2 is lower than 25%, it would be considered as low inconsistency [28]. In other words, the studies were considered substantial heterogeneity, if the I2 is greater than 50%. When heterogeneity existed, the pooled estimate should be based on the random-effects model. The random-effects model was based on the inverse variance method, using the DerSimonian-Laird method, introducing the correction for the weight in the fixed-effects model [29]. The meta-regression model would be established in the meta package in R to explore the source of heterogeneity [30]. Publication bias was examined using the Egger’s test. P value > 0.05 was considered to be representative [31].
Results
Literature search and selection of studies
Of the 662 publications initially identified (n = 662), 637 were excluded based on titles and abstracts. After a full-text review of the remaining 25 studies, 12 studies were excluded, because the parameter of radius QUS was not SOS or absolute numbers of OR, RR, and HR data or their 95%CI were absent. Finally, 13 studies were included for the meta-analysis (Fig. 1).
Moilanen et al. [32] conducted a retrospective study to evaluate the discrimination ability of a custom-made ultrasound, which measured the shaft of the radius. Tao et al. [33] assessed the use of QUS measured at the distal radius in determining the risk of nonvertebral fracture in postmenopausal Chinese women. Sensitivity and specificity, rather than OR, were used to describe the nonvertebral fracture discrimination ability of radius QUS. Grampp et al. [34] compared the different noninvasive bone mineral measurements in fracture discrimination and others. They calculated the OR but applied two QUS in the calcaneus. Li et al. [35] conducted a case-control study in Beijing, China, to evaluate the ability of radius QUS for predicting the fracture risk. But they roughly divided the participants into two groups according to their SOS value. Goemaere et al. [23] conducted a community-dwelling study on elderly men about the QUS measure at the tibia. Damilakis et al. [22] compared the radial BMD and SOS with axial BMD rather than fracture discrimination. The study conducted by Schousboe et al. [36] focused on a novel pulse-echo ultrasound device, which may indicate DI (density indices, a combination of cortical thickness, age, weight, and height) rather than SOS. Five articles [37,38,39,40] are excluded because they all concentrated on the pulse-echo ultrasound called the Bindex ultrasound device, which also used DI as a parameter.
Study description and characteristics
The basic characteristics of the included studies were presented in Table 1. And the RRs, HRs, ORs, 95%CI, and its adjusted confounding factors were extracted in Table 2. There were 13 studies included, consisting of 3 cohort studies [41,42,43] and 10 case-control studies [44,45,46,47,48,49,50,51,52,53].
The year of publication ranges from 1999 to 2019. These studies were conducted in the UK, Germany, France, Switzerland, Israel, Canada, Australia, and Korea. Lee at al. [42] conducted the only study promoted in Asia. Besides, 3 studies focused only on hip fractures [49, 50, 53], 1 study focused on vertebral fractures [51], 2 study focused on nonspine fractures [41, 42], while another 7 studies focused on all types of osteoporotic fractures [43,44,45,46,47,48, 52]. A total of 16,681 individuals were included in this review. Among the participants, 5892 were male and 10,789 were female. Of the women included, 1744 were clearly recorded as postmenopausal women. However, taking the age range of the included women into consideration, it can be approximated that elderly female subjects over 60 years old, with no clear menopause records, are regarded as menopause. Three of these studies included men [41, 42, 44], while 10 studies only included women [43, 45,46,47,48,49,50,51,52,53], 6 of which focused on postmenopausal women [43, 45,46,47, 50, 51]. In the 13 included studies, there were 328 hip fractures, 269 vertebral fractures, 240 forearm fractures, 136 humerus fractures, 26 ankle fractures, 47 other fractures (including ribs, patella, pelvic), and 250 fractures without particularly sorted. Of these 13 included studies, 4 studies [43, 49, 51, 53] had recruited a minor healthy young population as a reference to express the results as radial SOS T-scores. Nine studies used the radius QUS equipment produced by the same company (Sunlight Medical, Ltd., Rehovot, Israel) [41, 42, 47,48,49,50,51,52,53], while 4 studies by other companies [43,44,45,46].
Among the 3 prospective cohort studies, Lee et al. [42] conducted the study in a large population from two cohorts in Korea, with 4619 women and 4732 men. This study had the largest sample size and the largest number of male subjects in all included studies. However, the duration of follow-up (3.86 years) seemed to be not enough compared with the other two cohort studies included (5.00 years and 5.47 years, respectively). Interestingly, we found out that during nearly 4 years of follow-up, there were more fracture events in the wrist in Asia (98 wrist fractures in 198 fracture events), while more in the hip in Caucasian (320 hip fractures and 142 forearm fractures in 1098 fractures events).
Fracture detection was a crucial part of our study. All studies emphasized that they only concentrated on low trauma, atraumatic fracture, low-energy fracture, or fragility fracture rather than fracture due to major trauma, vehicle accidents for example. In some of the included studies [41, 42, 44], some cases of the fractures were recorded by self-report, structured questionnaire, or face to face interviews. Other studies confirmed the fracture events by physician report, clinical or radiographic analysis. In most of the studies considering the vertebral fracture, the vertebral fracture was confirmed by radiographic reports. But in a cohort study conducted by Lee et al. [42], the vertebral fracture was confirmed by 4.0-cm height loss. It was suggested that two-thirds to three-fourths of vertebral fracture was without any clinical manifestation [54]. However, diagnosis of vertebral fracture by X-ray was more reliable than height loss. Four studies [47, 49, 50, 52] only included fractures that occurred within the last 6 months or 4 days before the QUS measurement, while the other studies did not make any special provision.
Besides, we should pay attention to the inclusion and exclusion criteria. It was clear that only low-energy fracture (caused by minimum or no trauma or a fall from standing height) was included. But when it came to the disease or drug that affects bone metabolism, there were different opinions. Some studies made a clear statement that subjects with any condition affecting bone metabolism should be excluded [42, 45, 46, 48,49,50,51,52,53], while the others did not.
Quality assessment
Quality assessment of the 13 eligible studies was outlined by the NOS statement. The assessment results were presented in Table 3. The quality scores were from 5 to 9, with an average score of 6.8. The average score and median score of cohort studies were 6. The median score of case-control studies was 7. And the average score of case-control studies was 7.1. High-quality studies (those assigned ≥ 7 stars) included one cohort study [43] and 7 case-control studies [44, 47,48,49,50,51, 53].
Relationship between radius QUS and fracture
The meta-analysis of the included studies was shown in Table 4. The pooled adjusted RR for fragility fracture per each SD decrease in radial SOS is 1.41 (95%CI: 1.21–1.64, I2 = 81.3%; Pheterogeneity < 0.0001), as shown in Fig. 2. There was large heterogeneity existed. To explore the source of heterogeneity, meta-regression analyses were established. The possible factors were listed below: study design, year of publication, sample size, race, gender, the menopausal status of women, fracture site, adjusted BMI, adjusted BMD of the femoral neck, quality scores, exclusion, and device. The corresponding P values were < 0.0001, 0.3116, 0.0050, 0.0109, 0.1115, 0.6588, 0.1434, 0.2355, 0.6797, 0.0370, 0.2040, and 0.8244, respectively. The results showed that the study design, the sample size, race, and quality scores were significant influencing factors, especially the study design.
Subgroup and sensitivity analyses
According to the gender, race, fracture site, menopausal status of women, sample size, study design, and quality, subgroup analyses were conducted, as shown in Table 4. When stratified by gender and race, the pooled RR in women or Caucasian women was higher than that in the overall analysis. There was no significant difference in the men group (Fig. 2 and Fig. 3). Similarly, the pooled RR from studies focused on hip fracture is 1.55 (95%CI: 1.06–2.28; I2 = 69.2%; Pheterogeneity = 0.0034). The pooled RR for hip fracture in women is 1.66 (95%Cl: 1.10–2.51; I2 = 73.1%; Pheterogeneity = 0.0023), while the pooled RR for hip fracture in postmenopausal women is 1.78 (95%CI: 1.06–3.01; I2 = 71.5%; Pheterogeneity = 0.0146), as shown in Fig. 4 and Fig. 5. The pooled RR for fragility fracture in postmenopausal women is 1.53 (95%CI: 1.21–1.93; I2 = 81.7%; Pheterogeneity < 0.0001 (Fig. 5). As mentioned before, the sample size may be a significant source of heterogeneity according to the result of meta-regression analyses. We divided the included studies into a small sample size group (sample size smaller than 500) and a large sample size group. Analysis on 5 large sample size groups yielded a pooled RR of 1.21 (95%CI: 1.00–1.45; I2 = 82.6%; Pheterogeneity < 0.0001) and pooled RR of 1.32 in women (95%CI: 1.04–1.67; I2 = 86.0%; Pheterogeneity < 0.0001), as shown in Fig. 6, but not significant in the small sample size group (Fig. 6). Moreover, in the cohort study group, the pooled RR in women is 1.05 (95%CI: 0.93–1.19; I2 = 70.7%; Pheterogeneity = 0.0331), while the pooled RR in the case-control study group is not significant (Fig. 7). When analyses restricted to 8 high-quality studies, the pooled RR is 1.61 (95%CI: 1.27–2.04; I2 = 83.2%; Pheterogeneity < 0.0001), as shown in Fig. 8.
Sensitivity analysis can be used to test the stability of the meta-analysis results. We recalculated the results by removing one study each time. Olszynski et al. [41] and Lee et al. [42] had conducted studies with large samples (3741 and 9351 respectively) among the included studies. After the omission of the study by Olszynski et al. [41] or the study by Lee et al. [42] respectively, the pooled RRs were similar and without large fluctuation.
Heterogeneity evaluation and publication bias
Significant heterogeneity should be noticed in our meta-analysis, as shown in Table 4. According to the result from meta-regression analysis, we conducted the subgroup analyses. Groups of small sample sizes and large sample sizes shared similar heterogeneity. But the heterogeneity had decreased in the Caucasian group, cohort study group, and case-control study group. Nevertheless, I2 of the cohort study group and the case-control study group was 49.7% and 35.0%. It was suggested that there may be other potential factors that caused heterogeneity.
The P values of Egger’s test were also shown in Table 4. The overall analysis had a publication bias. In the hip fracture group, no publication bias was found (P = 0.2077). Additionally, there was no publication bias in the postmenopausal women group, large sample size group, and cohort study group (P = 0.1814, P = 0.2027, and P = 0.7486, respectively). Corresponding funnel plots are shown in Fig. 9.
Discussion
Radius QUS, as a simple, versatile, noninvasive, radiation-free, inexpensive, and convenient technique, is used not only in osteoporosis screening but also for discrimination of fragility fractures. Radius QUS has a pretty short acquisition time. Compared with DXA, QUS also can diagnose osteoporosis, monitor the skeletal changes caused by diseases progress or some drugs or therapeutic interventions, and discriminate the people with a high risk of fractures. But some of these applications are still in the exploratory stage. Although many pieces of research were done on QUS, there were not many studies with high quality about the radius QUS. It is indicated that the peripheral QUS technique is capable of predicting people with low bone density at the axial skeleton as measured by DXA [55, 56]. And the calcaneus QUS had been confirmed as effective methods in fractures discrimination [12, 13, 57, 58]. So far, the fractures discriminative ability of radius QUS is still controversial.
Our study is the first meta-analysis study to evaluate the fracture discriminative ability of radius QUS. Finding from current studies suggested that each SD decrease in radial SOS is associated with an increase of risk of overall fragility fracture by 21%, and by 32% in women, specifically. Moreover, each SD decrease in radial SOS is associated with an increase of risk of hip fracture by 55%, by 66% in women, and by 78% in postmenopausal women. The results were robust across sensitivity analyses, and no publication bias had existed.
The association between the radial SOS and an increased risk of fragility fracture also suggested that radius QUS could be the prescreening tool for osteoporosis [55]. DXA is the gold standard for osteoporosis diagnosis. However, DXA is a plane density instead of a true volume density. Three-dimensional volume was transformed into a two-dimensional plane through the X-ray. It was indicated that BMD measured by DXA could represent the average density of the bone. As we all know, the bone consisted of cortical and trabecular bone, where the latter one was more sensitive to bone loss in the early stage of osteoporosis. Ultrasound offers additional information about cortical and trabecular microstructure [14, 15]. In other words, ultrasound can detect bone loss earlier than DXA and predict high fracture risk population [59, 60]. SOS, the velocity of an ultrasound wave, is defined by material properties of bone, such as trabecular orientation and mineral content, which closely relates to fracture risk. Besides, an in vitro study suggested that there was a remarkable correlation between the velocity with bone mineral content, which was better than broadband ultrasound attenuation [61].
It is generally accepted that calcaneus QUS can be used for osteoporosis screening and fracture risk evaluation, especially when DXA is not accessible. However, calcaneus QUS has some inherent disadvantages. Patients need to take off shoes and socks, which may decrease their compliance to cooperate, especially when outdoors or in winter. Besides, it brings sanitary concerns and might result in cross infection.
Compared with calcaneus QUS, radius QUS is more convenient and safer due to sanitary consideration. Radius QUS has great potential to be widely applied in screening for osteoporosis. However, a systematic review of the radius QUS is still lacking.
Based on our results, radius QUS showed comparable efficacy in hip fracture discrimination with calcaneus, while calcaneus QUS is better in the discrimination of overall fractures. It has been suggested in the meta-analysis published in 2006 [13] that RRs (95%CI) for overall fractures in women were 1.59 (1.31–1.95) and 1.55 (1.35–1.78) for each SD decrease in calcaneal SOS and BUA, respectively. An individual-level meta-analysis conducted by McCloskey et al. in 2015 [12] also confirmed that RRs (95%CI) for overall fractures were 1.42 (1.36–1.47) and 1.45 (1.40–1.51) per SD decrease of SOS and BUA of the calcaneus, respectively. In our meta-analysis, RR (95%CI) for overall fractures in women was 1.32 (1.04–1.67) for each SD decrease in radial SOS. In hip fracture discrimination, both radius and calcaneus QUS performed better. The RRs for hip fracture ranged from 1.60 to 1.75 for each SD decrease of SOS or BUA of calcaneus. And we found the RR (95%CI) for hip fracture in women was 1.66 (1.10–2.51).
Publication bias happens when favorable results have more opportunities to be published. It should not be neglected when we carefully inspect the rationality of the conclusion. To identify the publication bias, a funnel plot was commonly used. Generally, the funnel plot is a series of scatter diagram, which takes the effect value as the horizontal coordinate and the accuracy as the vertical coordinate. If there is no publication bias in included literature, the funnel plot will shape like a symmetric inverted funnel. However, the funnel plot is more suitable for a large number of studies. Egger’s test, based on the linear regression model to test the symmetry of the funnel plot, is more appropriate for identifying the bias quantificationally with a small number of included literature [31]. In other words, the P value of the Egger’s test would be the most appropriate method for publication bias evaluation in our meta-analysis rather than the qualitative observation of the funnel plots.
When trying to explain the publication bias, we noticed that among the included studies, those with a smaller sample size tend to report positive results. As we know, clinical studies with larger sample sizes are considered more valuable, no matter if the results are positive or not, and thus have more opportunity to be considered for publication. For those with smaller sample size, the opportunity becomes slimmer, especially when the results are negative. This may partly explain the existed publication bias. On the other hand, most of the studies with a small sample size were case-control studies. OR was likely to overestimate the RR due to its unavailability to the incidence rate. RR was commonly used in cohort study as the measure of the association between exposure factors and the risk of disease. Different from RR, the OR was used to express the chance that disease may occur. OR is particularly helpful for case-control study and is the only correct measure of effect size [62]. The OR can be used to estimate RR when the disease is not common in the studied population (the incidence of the disease less than 10%). As far as we know, the incidence rate of all types of fragility fracture in population over 50 years old was far below 10% [3, 63,64,65]. Herein, the ORs are approximated to the RRs in our meta-analysis [66]. And the HR differs from RR in that HR represents instantaneous risk over the study period, while RR represents a cumulative risk over the entire study period. In our meta-analysis, HRs were directly considered as RRs.
Heterogeneity still existed when we conducted the subgroup analyses. First, included studies focused on different sites of fracture, and some only focused on hip fracture or vertebral fracture, while others focused on any site of the fragility fracture. Second, different inclusion and exclusion criteria on participants, especially on people who are suffering from disease or accepting the therapy that affecting the bone metabolism, might lead to inevitable heterogeneity and bias. For example, fracture risk is modified in patients who were under anti-osteoporotic treatment. But these patients were not excluded in some studies, causing inevitable bias. Last but not the least, different QUS devices may cause heterogeneity. It could not be ignored that quality verification of the QUS is difficult to guarantee, especially among different devices. QUS devices are still not comparable, even the same parameters are measured. An appropriate standardization method is desirably needed. Nine studies used the radius QUS equipment produced by the same company (Sunlight Medical, Ltd., Rehovot, Israel). The Sunlight device is constantly updated based on the prototype, which was first put into clinical trials in 1999. The main difference between the other device and Sunlight device is the frequency of ultrasound. Hans et al. [50] conducted a study about the Sunlight Omnisense prototype. A specific handheld probe was designed for a distal radius. The frequency of the latest Sunlight device was 1.25 MHz. The frequency of the Signet device was 100–600 kHz. The OsCare Sono® is also designed with a low 200-kHz frequency and measures the low-frequency velocity of the radius. Nevertheless, ultrasound measurement by the Vennon is designed with a similar frequency as the Sunlight device (0.5–1.5 MHz). High-frequency ultrasound offers superior high resolution and high throughput and is more suitable for radius measurement without penetrating. At present, high-frequency ultrasound is still the mainstream choice among QUS equipment.
Despite our rigorous methodology, there are some limitations in our meta-analysis. First, our study included 13 studies, and only 5 of them had a sample size of no less than 500. Studies with a large population are needed for further evaluation of radius QUS. Second, our conclusion cannot apply directly to men, because only three studies included men as participants. However, fracture risk evaluation in men is as important as in women. It was widely recognized that men suffering from fragility fracture had the same morbidity and higher mortality than women [67]. Thirteen percent of Caucasian men over 50 years old have a risk of any fragility fracture in their lifetime [68]. And it is reported that the incidence rate of hip fracture is 217 per 100,000 person years in men in Japan [64]. However, those prospective studies concerning fragility fracture in men did not concentrate on radius QUS. Khaw et al. [69] conducted a prospective study in men and women, which suggested that calcaneum BUA predicted the total and hip fracture risk both in men and women. A cross-section study conducted in the older male in Italy showed that both calcaneum BUA and SOS each SD reduction attributed to the doubling of the hip fracture risk [70]. Welch et al. suggested sex differences between fracture risk and QUS measurement [71]. Thus, a further large population study about radius QUS in men is needed. Third, it is a pity that only one study on the Asian population was included. Previous studies suggested that there are differences in BMD among various ethnicities [4, 72]. Furthermore, SOS is associated with not only age but also gender and race, according to normative data from different populations [73, 74]. A cohort study with a large Asian population is needed.
Conclusion
In summary, the meta-analysis showed that each SD decrease in radial SOS contributed to the increase of total fragility fracture risk by 21%. The risk increases by 32% in women, particularly. Moreover, the risk of hip fracture is increased by 55% and by 66% in women with each SD decrease in radial SOS. Radius QUS had an association with total fragility fracture and hip fracture risk, especially in women. Due to the limited quantity of involved literature, further investigations with a large sample size are necessary before we reach a final conclusion.
References
(1991) Consensus development conference: prophylaxis and treatment of osteoporosis. Osteoporos Int 1:114–117. https://doi.org/10.1007/BF01880454
Hernlund E, Svedbom A, Ivergård M, Compston J, Cooper C, Stenmark J, McCloskey EV, Jönsson B, Kanis JA (2013) Osteoporosis in the European Union: medical management, epidemiology and economic burden: a report prepared in collaboration with the International Osteoporosis Foundation (IOF) and the European Federation of Pharmaceutical Industry Associations (EFPIA). Arch Osteoporos 8:136. https://doi.org/10.1007/s11657-013-0136-1
Driessen JHM, Hansen L, Eriksen SA, van Onzenoort HAW, Henry RMA, van den Bergh J, Abrahamsen B, Vestergaard P, de Vries F (2016) The epidemiology of fractures in Denmark in 2011. Osteoporos Int 27:2017–2025. https://doi.org/10.1007/s00198-016-3488-8
Lu YC, Lin YC, Lin YK, Liu YJ, Chang KH, Chieng PU, Chan WP (2016) Prevalence of osteoporosis and low bone mass in older Chinese population based on bone mineral density at multiple skeletal sites. Sci Rep 6:1–9. https://doi.org/10.1038/srep25206
International Osteoporosis Foundation (2009) The Asian audit: epidemiology, costs and burden osteoporosis in Asia 2009.
Braithwaite RS, Col NF, Wong JB (2003) Estimating hip fracture morbidity, mortality and costs. J Am Geriatr Soc 51:364–370. https://doi.org/10.1046/j.1532-5415.2003.51110.x
Turner DA, Fong R, Khioe S et al (2018) The cost-effectiveness of screening in the community to reduce osteoporotic fractures in older women in the UK: economic evaluation of the SCOOP Study. J Bone Miner Res 33:845–851. https://doi.org/10.1002/jbmr.3381
Johnell O, Kanis JA, Oden A, Johansson H, de Laet C, Delmas P, Eisman JA, Fujiwara S, Kroger H, Mellstrom D, Meunier PJ, Melton LJ III, O'Neill T, Pols H, Reeve J, Silman A, Tenenhouse A (2005) Predictive value of BMD for hip and other fractures. J Bone Miner Res 20:1185–1194. https://doi.org/10.1359/JBMR.050304
Watts NB (2011) The fracture risk assessment tool (FRAX®): Applications in clinical practice. J Women's Health 20:525–531. https://doi.org/10.1089/jwh.2010.2294
Langton CM, Njeh CF, Hodgskinson R, Currey JD (1996) Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation. Bone 18:495–503. https://doi.org/10.1016/8756-3282(96)00086-5
Langton M, Palmer SB, Porter RW (1984) Attenuation in cancellous bone. Eng Med 13:89–91
McCloskey EV, Kanis JA, Odén A, Harvey NC, Bauer D, González-Macias J, Hans D, Kaptoge S, Krieg MA, Kwok T, Marin F, Moayyeri A, Orwoll E, Gluёr C, Johansson H (2015) Predictive ability of heel quantitative ultrasound for incident fractures: an individual-level meta-analysis. Osteoporos Int 26:1979–1987. https://doi.org/10.1007/s00198-015-3072-7
Marín F, González-Macías J, Díez-Pérez A, Palma S, Delgado-Rodríguez M (2006) Relationship between bone quantitative ultrasound and fractures: a meta-analysis. J Bone Miner Res 21:1126–1135. https://doi.org/10.1359/jbmr.060417
Schultz K, Wolf JM (2019) Emerging technologies in osteoporosis diagnosis. J Hand Surg [Am] 44:240–243. https://doi.org/10.1016/j.jhsa.2018.07.006
Glüer CC (1997) Quantitative ultrasound techniques for the assessment of osteoporosis: expert agreement on current status. J Bone Miner Res 12:1280–1288. https://doi.org/10.1359/jbmr.1997.12.8.1280
Frost ML, Blake GM, Fogelman I (2000) Can the WHO criteria for diagnosing osteoporosis be applied to calcaneal quantitative ultrasound? Osteoporos Int 11:321–330. https://doi.org/10.1007/s001980070121
Trimpou P, Bosaeus I, Bengtsson BÅ, Landin-Wilhelmsen K (2010) High correlation between quantitative ultrasound and DXA during 7 years of follow-up. Eur J Radiol 73:360–364. https://doi.org/10.1016/j.ejrad.2008.11.024
Gnudi S, Malavolta N, Ripamonti C, Caudarella R (1995) Ultrasound in the evaluation of osteoporosis: a comparison with bone mineral density at distal radius. Br J Radiol 68:476–480. https://doi.org/10.1259/0007-1285-68-809-476
Njeh CF, Saeed I, Grigorian M, Kendler DL, Fan B, Shepherd J, McClung M, Drake WM, Genant HK (2001) Assessment of bone status using speed of sound at multiple anatomical sites. Ultrasound Med Biol 27:1337–1345. https://doi.org/10.1016/s0301-5629(01)00437-9
Editor T (2010) IOF World Congress on Osteoporosis & 10th European Congress on Clinical and Economic Aspects of Osteoporosis and Osteoarthritis. Osteoporos Int 21:25–388. https://doi.org/10.1007/s00198-010-1247-9
Oral A, Esmaeilzadeh S, Yalıman A, Sindel D, Kürsüz Köseoğlu P, Aydın T (2019) The ability of calcaneal and multisite quantitative ultrasound variables in the identification of osteoporosis in women and men. Turkish J Phys Med Rehabil 65:203–215. https://doi.org/10.5606/tftrd.2019.1894
Damilakis J, Papadokostakis G, Perisinakis K, Gourtsoyiannis N, Hadjipavlou A (2003) Can radial bone mineral density and quantitative ultrasound measurements reduce the number of women who need axial density skeletal assessment? Osteoporos Int 14:688–693. https://doi.org/10.1007/s00198-003-1420-5
Goemaere S, Zmierczak H, Van Pottelbergh I, Kaufman JM (2002) Ability of peripheral bone assessments to predict areal bone mineral density at hip in community-dwelling elderly men. J Clin Densitom 5:219–228
(2014) IOF Regionals – 5th Asia-Pacific Osteoporosis Meeting. Osteoporos Int 25:583–652. https://doi.org/10.1007/s00198-014-2892-1
Stang A (2010) Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol 25:603–605. https://doi.org/10.1007/s10654-010-9491-z
Wells G, Shea B, O’Connell D The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. http://www.ohri.ca/programs/clinical_epidemiology/oxford.asp. Accessed 29 February 2020
Higgins JPT, Thompson SG (2002) Quantifying heterogeneity in a meta-analysis. Stat Med 21:1539–1558. https://doi.org/10.1002/sim.1186
Grant J, Hunter A (2006) Measuring inconsistency in knowledgebases. J Intell Inf Syst 27:159–184. https://doi.org/10.1007/s10844-006-2974-4
DerSimonian R, Laird N (1986) Meta-analysis in clinical trials. Control Clin Trials 7:177–188. https://doi.org/10.1016/0197-2456(86)90046-2
Viechtbauer W (2010) Conducting meta-analyses in R with the metafor. J Stat Softw 36:1–48. https://doi.org/10.18637/jss.v036.i03
Egger M, Smith GD, Schneider M, Minder C (1997) Bias in meta-analysis detected by a simple, graphical test. Br Med J 315:629–634. https://doi.org/10.1136/bmj.316.7129.469
Moilanen P, Maatta M, Kilappa V et al (2013) Discrimination of fractures by low-frequency axial transmission ultrasound in postmenopausal females. Osteoporos Int 24:723–730. https://doi.org/10.1007/s00198-012-2022-x
Tao B, Liu J-M, Li X-Y, Wang JG, Wang WQ, Ning G (2008) An assessment of the use of quantitative ultrasound and the Osteoporosis Self-Assessment Tool for Asians in determining the risk of nonvertebral fracture in postmenopausal Chinese women. J Bone Miner Metab 26:60–65. https://doi.org/10.1007/s00774-007-0798-0
Grampp S, Genant HK, Mathur A, Lang P, Jergas M, Takada M, Glüer CC, Lu Y, Chavez M (1997) Comparisons of noninvasive bone mineral measurements in assessing age-related loss, fracture discrimination, and diagnostic classification. J Bone Miner Res 12:697–711. https://doi.org/10.1359/jbmr.1997.12.5.697
Li D, Xue Y, Guo S (2009) The value of quantitative ultrasound in predicting fracture risk 049(008):67-68
Schousboe JT, Riekkinen O, Karjalainen J (2017) Prediction of hip osteoporosis by DXA using a novel pulse-echo ultrasound device. Osteoporos Int 28:85–93. https://doi.org/10.1007/s00198-016-3722-4
Karjalainen JP, Riekkinen O, Kröger H (2018) Pulse-echo ultrasound method for detection of post-menopausal women with osteoporotic BMD. Osteoporos Int 29:1193–1199. https://doi.org/10.1007/s00198-018-4408-x
Karjalainen JP, Riekkinen O, Toyras J et al (2016) New method for point-of-care osteoporosis screening and diagnostics. Osteoporos Int 27:971–977. https://doi.org/10.1007/s00198-015-3387-4
(2016) Abstracts of osteoporosis conference 2016. Osteoporos Int 27:609–685. https://doi.org/10.1007/s00198-016-3743-z
(2015) Abstracts of osteoporosis conference 2015. Osteoporos Int 30. https://doi.org/10.1002/jbmr.2763
Olszynski WP, Brown JP, Adachi JD, Hanley DA, Ioannidis G, Davison KS, the CaMos Research Group (2013) Multisite quantitative ultrasound for the prediction of fractures over 5 years of follow-up: the Canadian Multicentre Osteoporosis Study. J Bone Miner Res 28:2027–2034. https://doi.org/10.1002/jbmr.1931
Lee SH, Khang Y-H, Lim K-H, Kim BJ, Koh JM, Kim GS, Kim H, Cho NH (2010) Clinical risk factors for osteoporotic fracture: a population-based prospective cohort study in Korea. J Bone Miner Res 25:369–378. https://doi.org/10.1359/jbmr.090722
Gnudi S, Ripamonti C, Malavolta N (2000) Quantitative ultrasound and bone densitometry to evaluate the risk of nonspine fractures: a prospective study. Osteoporos Int 11:518–523. https://doi.org/10.1007/s001980070095
Biver E, Pepe J, de Sire A, Chevalley T, Ferrari S (2019) Associations between radius low-frequency axial ultrasound velocity and bone fragility in elderly men and women. Osteoporos Int 30:411–421. https://doi.org/10.1007/s00198-018-4725-0
Schneider J, Varga P, Raum K et al (2015) Multisite ultrasound axial transmission study in postmenopausal women using optimized first arriving signal velocity measurements. 2015 6th European Symposium on Ultrasonic Characterization of Bone, Corfu
Talmant M, Kolta S, Roux C, Haguenauer D, Vedel I, Cassou B, Bossy E, Laugier P (2009) In vivo performance evaluation of bi-directional ultrasonic axial transmission for cortical bone assessment. Ultrasound Med Biol 35:912–919. https://doi.org/10.1016/j.ultrasmedbio.2008.12.008
Clowes JA, Eastell R, Peel NFA (2005) The discriminative ability of peripheral and axial bone measurements to identify proximal femoral, vertebral, distal forearm and proximal humeral fractures: a case control study. Osteoporos Int 16:1794–1802. https://doi.org/10.1007/s00198-005-1931-3
Nguyen TV, Center JR, Eisman JA (2004) Bone mineral density-independent association of quantitative ultrasound measurements and fracture risk in women. Osteoporos Int 15:942–947. https://doi.org/10.1007/s00198-004-1717-z
Hans D, Genton L, Allaoua S, Pichard C, Slosman DO (2003) Hip fracture discrimination study: QUS of the radius and the calcaneum. J Clin Densitom 6:163–172. https://doi.org/10.1385/JCD:6:2:163
Hans D, Srivastav SK, Singal C, Barkmann R, Njeh CF, Kantorovich E, Glüer CC, Genant HK (1999) Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture? J Bone Miner Res 14:644–651. https://doi.org/10.1359/jbmr.1999.14.4.644
Knapp KM, Blake GM, Spector TD, Fogelman I (2001) Multisite quantitative ultrasound: precision, age- and menopause-related changes, fracture discrimination, and T-score equivalence with dual-energy X-ray absorptiometry. Osteoporos Int 12:456–464. https://doi.org/10.1007/s001980170090
Barkmann R, Kantorovich E, Singal C, Hans D, Genant HK, Heller M, Glüer CC (2000) A new method for quantitative ultrasound measurements at multiple skeletal sites: first results of precision and fracture discrimination. J Clin Densitom 3:1–7
Weiss M, Ben-Shlomo A, Hagag P, Ish-Shalom S (2000) Discrimination of proximal hip fracture by quantitative ultrasound measurement at the radius. Osteoporos Int 11:411–416. https://doi.org/10.1007/s001980070108
Fink HA, Milavetz DL, Palermo L, Nevitt MC, Cauley JA, Genant HK, Black DM, Ensrud KE, Fracture Intervention Trial Research Group (2005) What proportion of incident radiographic vertebral deformities is clinically diagnosed and vice versa? J Bone Miner Res 20:1216–1222. https://doi.org/10.1359/JBMR.050314
Cook RB, Collins D, Tucker J, Zioupos P (2005) The ability of peripheral quantitative ultrasound to identify patients with low bone mineral density in the hip or spine. Ultrasound Med Biol 31:625–632. https://doi.org/10.1016/j.ultrasmedbio.2005.02.003
Cook RB, Collins D, Tucker J, Zioupos P (2005) Comparison of questionnaire and quantitative ultrasound techniques as screening tools for DXA. Osteoporos Int 16:1565–1575. https://doi.org/10.1007/s00198-005-1864-x
Fitzgerald GE, Anachebe T, McCarroll KG, O’Shea F (2020) Calcaneal quantitative ultrasound has a role in out ruling low bone mineral density in axial spondyloarthropathy. Clin Rheumatol 39:1971–1979. https://doi.org/10.1007/s10067-019-04876-9
Hernández JL, Marin F, González-Macías J et al (2004) Discriminative capacity of calcaneal quantitative ultrasound and of osteoporosis and fracture risk factors in postmenopausal women with osteoporotic fractures. Calcif Tissue Int 74:357–365. https://doi.org/10.1007/s00223-003-0158-6
Lin W, Serra-Hsu F, Cheng J, Qin YX (2012) Frequency specific ultrasound attenuation is sensitive to trabecular bone structure. Ultrasound Med Biol 38:2198–2207. https://doi.org/10.1016/j.ultrasmedbio.2012.07.020
Cheng J, Serra-Hsu F, Tian Y, Lin W, Qin YX (2011) Effects of phase cancellation and receiver aperture size on broadband ultrasonic attenuation for trabecular bone in vitro. Ultrasound Med Biol 37:2116–2125. https://doi.org/10.1016/j.ultrasmedbio.2011.08.009
Tavakoli MB, Evans JA (1991) Dependence of the velocity and attenuation of ultrasound in bone on the mineral content. Phys Med Biol 36:1529–1537. https://doi.org/10.1088/0031-9155/36/11/012
Sistrom CL, Garvan CW (2004) Proportions, odds, and risk. Radiology 230:12–19. https://doi.org/10.1148/radiol.2301031028
Holloway KL, Sajjad MA, Mohebbi M, Kotowicz MA, Livingston PM, Khasraw M, Hakkennes S, Dunning TL, Brumby S, Page RS, Pedler D, Sutherland A, Venkatesh S, Brennan-Olsen SL, Williams LJ, Pasco JA (2018) The epidemiology of hip fractures across western Victoria, Australia. Bone 108:1–9. https://doi.org/10.1016/j.bone.2017.12.007
Tsukutani Y, Hagino H, Ito Y, Nagashima H (2015) Epidemiology of fragility fractures in Sakaiminato, Japan: incidence, secular trends, and prognosis. Osteoporos Int 26:2249–2255. https://doi.org/10.1007/s00198-015-3124-z
Briot K, Maravic M, Roux C (2015) Changes in number and incidence of hip fractures over 12 years in France. Bone 81:131–137. https://doi.org/10.1016/j.bone.2015.07.009
Zhang J, Yu K (1998) What’s the relative risk? A method of correcting the odds ratio in cohort studies of common outcomes. J Am Med Assoc 280:1690–1691
Olszynski WP, Shawn Davison K, Adachi JD, Brown JP, Cummings SR, Hanley DA, Harris SP, Hodsman AB, Kendler D, McClung MR, Miller PD, Yuen CK (2004) Osteoporosis in men: epidemiology, diagnosis, prevention, and treatment. Clin Ther 26:15–28. https://doi.org/10.1016/s0149-2918(04)90002-1
Melton LJ, Chrischilles EA, Cooper C et al (2005) How many women have osteoporosis? JBMR Anniversary Classic. JBMR, Volume 7, Number 9, 1992. J Bone Miner Res 20:886–892. https://doi.org/10.1359/jbmr.2005.20.5.886
Khaw KT, Reeve J, Luben R, Bingham S, Welch A, Wareham N, Oakes S, Day N (2004) Prediction of total and hip fracture risk in men and women by quantitative ultrasound of the calcaneus: EPIC-Norfolk prospective population study. Lancet 363:197–202. https://doi.org/10.1016/S0140-6736(03)15325-1
Varenna M, Sinigaglia L, Adami S, Giannini S, Isaia G, Maggi S, Filipponi P, di Munno O, Maugeri D, de Feo D, Crepaldi G (2005) Association of quantitative heel ultrasound with history of osteoporotic fractures in elderly men: The ESOPO study. Osteoporos Int 16:1749–1754. https://doi.org/10.1007/s00198-005-1914-4
Welch A, Camus J, Dalzell N, Oakes S, Reeve J, Khaw KT (2004) Broadband ultrasound attenuation (BUA) of the heel bone and its correlates in men and women in the EPIC-Norfolk cohort: a cross-sectional population-based study. Osteoporos Int 15:217–225. https://doi.org/10.1007/s00198-003-1410-7
Wu XP, Liao EY, Huang G, Dai RC, Zhang H (2003) A comparison study of the reference curves of bone mineral density at different skeletal sites in native Chinese, Japanese, and American Caucasian women. Calcif Tissue Int 73:122–132. https://doi.org/10.1007/s00223-002-1069-7
Drake WM, McClung M, Njeh CF, Genant HK, Rosen C, Watts N, Kendler DL (2001) Multisite bone ultrasound measurement on North American female reference population. J Clin Densitom 4:239–248. https://doi.org/10.1385/JCD:4:3:239
Hayman SR, Drake WM, Kendler DL, Olszynski WP, Webber CE, Rosen CJ, Genant HK, Orwoll ES, Pickard LE, Adachi JD (2002) North American male reference population for speed of sound in bone at multiple skeletal sites. J Clin Densitom 5:63–71. https://doi.org/10.1385/JCD:5:1:063
Funding
This study was supported by Bioland Laboratory (Guangzhou Regenerative Medicine and Health Guangdong Laboratory) (No. 1102101201).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
None.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/.
About this article
Cite this article
Fu, Y., Li, C., Luo, W. et al. Fragility fracture discriminative ability of radius quantitative ultrasound: a systematic review and meta-analysis. Osteoporos Int 32, 23–38 (2021). https://doi.org/10.1007/s00198-020-05559-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00198-020-05559-x