Abstract
Purpose
The purpose of the current study was to assess the clinical and radiological results after locking T-plate osteosynthesis with coracoclavicular augmentation of unstable and displaced distal clavicle fractures (Neer type 2).
Methods
Thirty patients, treated between January 2007 and January 2010 were followed up after a median follow-up time of 12.2 months (range 4.7–37.2). The Constant and DASH scores were used to evaluate the clinical outcome, and anterior–posterior and 30° cephalic view radiographs were performed to assess the bony healing.
Results
In all patients, the fracture healing was achieved within the first 10 weeks after surgery. All patients regained good or excellent shoulder function and returned to previous occupation and activity levels. The mean Constant and DASH scores were 92.3 points and 6.2 points, respectively. We did not observe any severe intra- or post-operative complication within the time of follow-up.
Conclusion
The presented technique turned out to be a reliable method providing good results without showing severe complications.
Level of evidence
Case series, Level IV.
Similar content being viewed by others
References
Badhe SP, Lawrence TM, Clark DI (2007) Tension band suturing for the treatment of displaced type 2 lateral end clavicle fractures. Arch Orthop Trauma Surg 127(1):25–28
Ballmer FT, Gerber C (1991) Coracoclavicular screw fixation for unstable fractures of the distal clavicle. A report of five cases. J Bone Joint Surg Br 73(2):291–294
Baumgarten KM (2008) Arthroscopic fixation of a type II-variant, unstable distal clavicle fracture. Orthopedics 31(12):1236
Bezer M, Aydin N, Guven O (2005) The treatment of distal clavicle fractures with coracoclavicular ligament disruption: a report of 10 cases. J Orthop Trauma 19(8):524–528
Chaudry SN, Waseem M (2006) Clavicular hook plate: complications of retaining the implant. Injury 37(7):665
Checchia SL, Doneux PS, Miyazaki AN, Fregoneze M, Silva LA (2008) Treatment of distal clavicle fractures using an arthroscopic technique. J Shoulder Elbow Surg 17(3):395–398
Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164
Edwards DJ, Kavanagh TG, Flannery MC (1992) Fractures of the distal clavicle: a case for fixation. Injury 23(1):44–46
Eskola A, Vainionpaa S, Myllynen P, Patiala H, Rokkanen P (1986) Outcome of clavicular fracture in 89 patients. Archives of orthopaedic and traumatic surgery Archiv fur orthopadische und Unfall-Chirurgie 105(6):337–338
Flinkkila T, Ristiniemi J, Hyvonen P, Hamalainen M (2002) Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation. Acta Orthop Scand 73(1):50–53
Flinkkila T, Ristiniemi J, Lakovaara M, Hyvonen P, Leppilahti J (2006) Hook-plate fixation of unstable lateral clavicle fractures: a report on 63 patients. Acta Orthop 77(4):644–649
Gerhardt DC, VanDerWerf JD, Rylander LS, McCarty EC (2011) Postoperative coracoid fracture after transcoracoid acromioclavicular joint reconstruction. J Shoulder Elbow Surg 20(5):e6–e10
Haidar SG, Krishnan KM, Deshmukh SC (2006) Hook plate fixation for type II fractures of the lateral end of the clavicle. J Shoulder Elbow Surg 15(4):419–423
Herrmann S, Schmidmaier G, Greiner S (2009) Stabilisation of vertical unstable distal clavicular fractures (Neer 2b) using locking T-plates and suture anchors. Injury 40(3):236–239
Hessmann M, Kirchner R, Baumgaertel F, Gehling H, Gotzen L (1996) Treatment of unstable distal clavicular fractures with and without lesions of the acromioclavicular joint. Injury 27(1):47–52
Hsu TL, Hsu SK, Chen HM, Wang ST (2010) Comparison of hook plate and tension band wire in the treatment of distal clavicle fractures. Orthopedics 33(12):879–883
Hudak PL, Amadio PC, Bombardier C (1996) Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG). Am J Ind Med 29(6):602–608
Jerosch J, Filler T, Peuker E, Greig M, Siewering U (1999) Which stabilization technique corrects anatomy best in patients with AC-separation? An experimental study. Knee Surg Sports Traumatol Arthrosc 7(6):365–372
Kaipel M, Majewski M, Regazzoni P (2010) Double-plate fixation in lateral clavicle fractures-a new strategy. J Trauma 69(4):896–900
Kalamaras M, Cutbush K, Robinson M (2008) A method for internal fixation of unstable distal clavicle fractures: early observations using a new technique. J Shoulder Elbow Surg 17(1):60–62
Kao FC, Chao EK, Chen CH, Yu SW, Chen CY, Yen CY (2001) Treatment of distal clavicle fracture using Kirschner wires and tension-band wires. J Trauma 51(3):522–525
Kashii M, Inui H, Yamamoto K (2006) Surgical treatment of distal clavicle fractures using the clavicular hook plate. Clin Orthop Relat Res 447:158–164
Katolik LI, Romeo AA, Cole BJ, Verma NN, Hayden JK, Bach BR (2005) Normalization of the constant score. J Shoulder Elbow Surg 14(3):279–285
Largo RD, Rudin MA, Hotz TK, Valderrabano V, Kach KK (2011) Anatomic reconstruction of unstable lateral clavicular fractures. J Trauma 71(5):1348–1351
Lee YS, Lau MJ, Tseng YC, Chen WC, Kao HY, Wei JD (2009) Comparison of the efficacy of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle. Int Orthop 33(5):1401–1405
Lyons FA, Rockwood CA Jr (1990) Migration of pins used in operations on the shoulder. J Bone Joint Surg Am 72(8):1262–1267
Macheras G, Kateros KT, Savvidou OD, Sofianos J, Fawzy EA, Papagelopoulos PJ (2005) Coracoclavicular screw fixation for unstable distal clavicle fractures. Orthopedics 28(7):693–696
Neer CS 2nd (1963) Fracture of the distal clavicle with detachment of the coracoclavicular ligaments in adults. J Trauma 3:99–110
Neer CS 2nd (1968) Fractures of the distal third of the clavicle. Clin Orthop Relat Res 58:43–50
Nourissat G, Kakuda C, Dumontier C, Sautet A, Doursounian L (2007) Arthroscopic stabilization of Neer type 2 fracture of the distal part of the clavicle. Arthroscopy 23(6):e671–e674
Pujol N, Philippeau JM, Richou J, Lespagnol F, Graveleau N, Hardy P (2008) Arthroscopic treatment of distal clavicle fractures: a technical note. Knee Surg Sports Traumatol Arthrosc 16(9):884–886
Robinson CM, Akhtar MA, Jenkins PJ, Sharpe T, Ray A, Olabi B (2010) Open reduction and endobutton fixation of displaced fractures of the lateral end of the clavicle in younger patients. J Bone Joint Surg Br 92(6):811–816
Takase K, Kono R, Yamamoto K (2012) Arthroscopic stabilization for Neer type 2 fracture of the distal clavicle fracture. Arch Orthop Trauma Surg 132(3):399–403
Tambe AD, Motkur P, Qamar A, Drew S, Turner SM (2006) Fractures of the distal third of the clavicle treated by hook plating. Int Orthop 30(1):7–10
Tischer T, Salzmann GM, El-Azab H, Vogt S, Imhoff AB (2009) Incidence of associated injuries with acute acromioclavicular joint dislocations types III through V. Am J Sports Med 37(1):136–139
Yoo JH, Chang JD, Seo YJ, Shin JH (2009) Stable fixation of distal clavicle fracture with comminuted superior cortex using oblique T-plate and cerclage wiring. Injury 40(4):455–457
Acknowledgments
Neither the author nor the co-authors have to declare any conflicts of interest.
Ethics standard
IRB approval No. 5067/11 (ethics commission University Clinic rechts der Isar, Munich).
Author information
Authors and Affiliations
Corresponding author
Additional information
Frank Martetschläger and Tobias M. Kraus have contributed equally to this article.
Rights and permissions
About this article
Cite this article
Martetschläger, F., Kraus, T.M., Schiele, C.S. et al. Treatment for unstable distal clavicle fractures (Neer 2) with locking T-plate and additional PDS cerclage. Knee Surg Sports Traumatol Arthrosc 21, 1189–1194 (2013). https://doi.org/10.1007/s00167-012-2089-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-012-2089-0