Skip to main content
Log in

Does indocyanine green accurately measure plasma volume independently of its disappearance rate from plasma in critically ill patients?

  • ORIGINAL
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

Objective: To determine whether plasma volume determined by the indocyanine green (ICG) dilution method (PV-ICG) is equally accurate independently of its disappearance rate from plasma in the critically ill.¶Design: Retrospective clinical investigation.¶Setting: Intensive care unit of a university teaching hospital.¶Patients and methods: 192 adult patients were initially enrolled. The PV-ICG and the initial distribution volume of glucose (IDVG) were calculated utilizing a one-compartment model by simultaneous administration of ICG 25 mg and glucose 5 g on the first day of measurement in each patient. Twenty-one patients were excluded from the study because of a higher PV-ICG/IDVG ratio ( > 0.45) indicating apparent overestimation of the PV-ICG associated with the generalized protein capillary leakage. The remaining 171 patients were divided into four groups according to the magnitude of their disappearance rate of ICG from plasma (Ke-ICG).¶Results: Convergence was assumed consistently in each ICG or glucose decay curve, even in the lower Ke-ICG less than 0.10/min. The relationship between the two volumes was not statistically different among groups.¶Conclusions: The results suggest that the measurement of the PV-ICG can be equally accurate independently of its disappearance rate from plasma unless there is generalized protein capillary leakage.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 10 February 1999/Final revision received: 28 June 1999/Accepted: 21 July 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ishihara, H., Iwakawa, T., Hasegawa, T. et al. Does indocyanine green accurately measure plasma volume independently of its disappearance rate from plasma in critically ill patients?. Intensive Care Med 25, 1252–1258 (1999). https://doi.org/10.1007/s001340051053

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s001340051053

Navigation