A modified method of measuring plasma volume with indocyanine green: reducing the frequency of blood sampling while maintaining accuracy

  • Original Research
  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

Among various methods for measuring the plasma volume (PV), the indocyanine green (ICG) dilution technique is a relatively less invasive method. However, the ICG method is rather cumbersome because 10 blood samples need to be obtained within a short time after ICG administration. Thus, reducing the frequency of blood sampling while maintaining the accuracy would facilitate plasma volume measurement in clinical situations. We here developed a modified method to measure plasma volume using 2260 ICG plasma concentration data from 115 surgical patients. The mean relative error (MRE) and the percentage of cases with relative error (RE) greater than 5% in total (PRE) were used to quantify the difference between plasma volumes obtained by the original and modified methods. RE was determined as follows. RE(%) = (PV obtained by original method (PVoriginal)—PV obtained by modified method (PVmodified))/PVoriginal × 100. PVmodified was assumed to be equal to PVoriginal when the RE was < 5%. When the number of samples selected for the plasma volume estimation was 4 or less, the PRE was mostly 10% or more. Five out of the 10 blood samples (order: 1st, 2nd, 3rd, 9th, and 10th) showed similar accuracies with the plasma volume obtained by the original method (original: 2.72 ± 0.64 l, modified: 2.72 ± 0.65 l). This modified method may be able to aptly replace the original method and lead to a wider clinical application of the ICG dilution technique. Further validation is needed to determine if the results of this study may be applied in other populations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Hopf HW, Morrissey C. Perioperative fluid management: turning art to science. Anesthesiology. 2019;130:677–9. https://doi.org/10.1097/ALN.0000000000002663.

    Article  PubMed  Google Scholar 

  2. Jacob M, Conzen P, Finsterer U, Krafft A, Becker BF, Rehm M. Technical and physiological background of plasma volume measurement with indocyanine green: a clarification of misunderstandings. J Appl Physiol. 2007;102:1235–42. https://doi.org/10.1152/japplphysiol.00740.2006.

    Article  CAS  PubMed  Google Scholar 

  3. Lee YH, Jang HW, Park CH, An SM, Lee EK, Choi BM, Noh GJ. Changes in plasma volume before and after major abdominal surgery following stroke volume variation-guided fluid therapy: a randomized controlled trial. Minerva Anestesiol. 2019. https://doi.org/10.23736/S0375-9393.19.13952-1.

    Article  PubMed  Google Scholar 

  4. Aguree S, Gernand AD. An efficient method for measuring plasma volume using indocyanine green dye. MethodsX. 2019;6:1072–83. https://doi.org/10.1016/j.mex.2019.05.003.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Hart D, Metz J. The estimation of red cell volume with 51Cr-labelled erythrocytes and plasma volume with radioiodinated human serum albumin. J Clin Pathol. 1962;15:459–61. https://doi.org/10.1136/jcp.15.5.459.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  6. Gibson JG, Evans WA. Clinical studies of the blood volume. I. Clinical application of a method employing the azo dye "Evans Blue" and the spectrophotometer. J Clin Investig. 1937;16:301–16. https://doi.org/10.1172/JCI100859.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  7. He YL, Tanigami H, Ueyama H, Mashimo T, Yoshiya I. Measurement of blood volume using indocyanine green measured with pulse-spectrophotometry: its reproducibility and reliability. Crit Care Med. 1998;26:1446–511. https://doi.org/10.1097/00003246-199808000-00036.

    Article  CAS  PubMed  Google Scholar 

  8. Kim GY, Bae KS, Noh GJ, Min WK. Estimation of indocyanine green elimination rate constant k and retention rate at 15 min using patient age, weight, bilirubin, and albumin. J Hepatobiliary Pancreat Surg. 2009;16:521–8. https://doi.org/10.1007/s00534-009-0097-3.

    Article  PubMed  Google Scholar 

  9. Vos JJ, Scheeren TW, Loer SA, Hoeft A, Wietasch JK. Do intravascular hypo- and hypervolaemia result in changes in central blood volumes? Br J Anaesth. 2016;116:46–53. https://doi.org/10.1093/bja/aev358.

    Article  CAS  PubMed  Google Scholar 

  10. Cottis R, Magee N, Higgins DJ. Haemodynamic monitoring with pulse-induced contour cardiac output (PiCCO) in critical care. Intensive Crit Care Nurs. 2003;19:301–7. https://doi.org/10.1016/s0964-3397(03)00063-6.

    Article  PubMed  Google Scholar 

  11. Galstyan G, Bychinin M, Alexanyan M, Gorodetsky V. Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods. Intensive Care Med. 2010;36:2140–4. https://doi.org/10.1007/s00134-010-2003-5.

    Article  PubMed  Google Scholar 

  12. Krivitski NM, Kislukhin VV, Thuramalla NV. Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients. Pediatr Crit Care Med. 2008;9:423–8. https://doi.org/10.1097/01.PCC.0b013e31816c71bc.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Sekimoto M, Fukui M, Fujita K. Plasma volume estimation using indocyanine green with biexponential regression analysis of the decay curves. Anaesthesia. 1997;52:1166–72. https://doi.org/10.1111/j.1365-2044.1997.249-az0389.x.

    Article  CAS  PubMed  Google Scholar 

  14. Nurunnabi AAM, Nasser M, Imon AHMR. Identification and classification of multiple outliers, high leverage points and influential observations in linear regression. J Appl Stat. 2016;43:509–25. https://doi.org/10.1080/02664763.2015.1070806.

    Article  Google Scholar 

  15. Dworkin HJ, Premo M, Dees S. Comparison of red cell and whole blood volume as performed using both chromium-51-tagged red cells and iodine-125-tagged albumin and using I-131-tagged albumin and extrapolated red cell volume. Am J Med Sci. 2007;334:37–40. https://doi.org/10.1097/MAJ.0b013e3180986276.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank Dr Joon Seo Lim from the Scientific Publications Team at Asan Medical Center for his editorial assistance in preparing this manuscript.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Byung-Moon Choi or Eun-Kyung Lee.

Ethics declarations

Conflict of interest

All authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, K.M., Park, DY., Kang, EH. et al. A modified method of measuring plasma volume with indocyanine green: reducing the frequency of blood sampling while maintaining accuracy. J Clin Monit Comput 35, 779–785 (2021). https://doi.org/10.1007/s10877-020-00536-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10877-020-00536-5

Keywords

Navigation