Abstract
Objective:
To analyse the results of the treatment of aseptic femoral non-unions using a singular locked implant.
Design:
Consecutive case series.
Setting:
A level-1 trauma center with a high number of specialist referrals.
Patients:
The study is based on a consecutive series of patients with prospective data evaluation. From 1993 to 2003, 75 patients were treated with a wave plate. All patients had persistent non-union of the femoral shaft without clinical or laboratory signs of infection and previous unsuccessful attempts to treat the non-union.
Intervention:
The method of treatment was standardized and included a lateral approach, cancellous bone hip grafting, osteosynthesis with a wave-shaped plate (PPF) and polyaxial locking screws as well as the application of a gentamicin-PMMA chain.
Main Outcome Measurements:
Time to achieve union, rate of implant failure and number of remaining nonunions after treatment. A total of 75 patients had full follow-up and were included in the study.
Results:
The union of the fracture was found in 64 patients after the initial procedure. In eight cases a second procedure was performed to achieve union in the form of a second bone graft because of a delay in callus formation. The mean time to union was 7.3 months with a range from 3 to 19 months. The implant failed in three cases accounting for 4% of the total.
Conclusion:
The locked wave plate offers a further reliable treatment for complex aseptic femoral non-unions.
Similar content being viewed by others
References
Weber BG, Cech O. Pseudarthrosis. Grune and Stratton, New York, 1976.
Weber BG, Brunner C. Special Techniques in Internal Fixation. Springer, Berlin, 1982.
Blatter G, Weber BG. Wave plate osteosynthesis as a salvage procedure. Arch Orthop Trauma Surg 1990;109:330–3.
Seide K, Zierold W, Wolter D, et al. Einfluβ einer winkelstabilen Platten-Schrauben-Verbindung und unterschiedlicher Schraubendicken auf die Statik der Plattenosteosynthese, eine FEMStudie. Unfallchirurg 1990;93:552–8.
Wolter D. Der Plattenfixateur interne für lange Röhrenknochen. In: Wolter D, Zimmer W (eds) Die Plattenosteosynthese und ihre Konkurrenzverfahren. 1 edition Springer, Berlin 1991.
Wenzl M E, Wolter D, Fuchs S, et al. Druckplattenfixateur interne für das Femur, ein winkelstabiles Implantat. Trauma und Berufskr 1999;1:344–50.
Küntscher G (1940) Die Technik der Marknagelung des Oberschenkels. Zentralblatt f Chir 25.
Böhler L (1944) Die Technik der Knochenbruchbehandlung im Frieden und im Kriege. In: Die Marknagelung nach Küntscher, 1885–1892, vol III, 9th–11th edn. Wilhelm Maudrich Verlag, Wien.
Rüedi TP, Luscher JN. Results after internal fixation of comminuted fractures of the femoral shaft with DC plates. Clin Orthop Relat Res 1979;138:74–6.
Krettek C, Rudolf J, Schandelmaier P, et al. Unreamed intramedullary nailing of femoral shaft fractures: operative technique and early clinical experience with the standard locking option. Injury 1996;27:233.
Ricci WM, Bellabarba C, Evanoff B, et al. Retrograde versus antegrade nailing of femoral shaft fractures. J Orthop Trauma 2001;15:161–9.
Pihlajamaki HK, Salminen ST, Bostman OM. The treatment of nonunions following intramedullary nailing of femoral shaft fractures. J Orthop Trauma 2002;6:394–402.
The Canadian Orthopaedic Trauma Society Nonunion following intramedullary nailing of the femur with and without reaming. Results of a multicenter randomized clinical trial. J Bone Joint Surg (Am) 2003;85:2093–6.
Lambiris E, Panagopoulos A, Zouboulis P, Sourgiadaki E. Current concepts: aseptic nonunion of femoral shaft diaphysis. Eur J Trauma Emerg Surg 2007;3:120–34.
Schütz M, Müller M, Krettek C, et al. Minimally invasive fracture stabilization of distal femoral fractures with LISS: a prospective multicenter study–results of a clinical study with special emphasis on difficult cases. Injury 2001;32:48–54.
Cove JA, Lhowe DW, Jupiter JB, et al. The management of femoral diaphyseal nonunions. J Orthop Trauma 1997;11:513–20.
Finkemeier CG, Chapman MW. Treatment of femoral diaphyseal nonunions. Clin Orthop Relat Res 2002;398:223–34.
Hak DJ, Lee SS, Goulet JA. Success of exchange reamed intramedullary nailing for femoral shaft nonunion or delayed union. J Orthop Trauma 2000;14:178–82.
Weresh MJ, Hakanson R, Stover MD, et al. Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures. J Orthop Trauma 2000;14:335–8.
Blatter G, Gasser B, Weber BG. Die Wellenplatte. AO Bulletin, Version 29, Davos, Switzerland, 1989.
Seide K, Morlock MM, Schuemann U, et al. Mechanical effects of the locked screw plate interface in internal fixator osteosynthesis. Trauma Berufskrankh 1999;1:320–5.
Ring D, Jupiter JB, Sanders RA, et al. Complex nonunion of fractures of the femoral shaft treated by wave plate osteosynthesis. J Bone Joint Surg 1997;79B:289–94.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Schulz, A.P., Faschingbauer, M., Seide, K. et al. Is the Wave Plate Still a Salvage Procedure for Femoral Non-union? Results of 75 Cases Treated with a Locked Wave Plate. Eur J Trauma Emerg Surg 35, 127–131 (2009). https://doi.org/10.1007/s00068-008-8009-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00068-008-8009-9