An experimental study on using a diagnostic computed radiography system as a quality assurance tool in radiotherapy

  • Technical Report
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

The advent of improved digital imaging modalities in diagnostic and therapy is fast making conventional films a nonexistent entity. However, several radiotherapy centers still persist with film for performing quality assurance (QA) tests. This paper investigates the feasibility of using a diagnostic computed radiography (CR) system as a QA tool in radiotherapy. QA tests such as light field congruence, field size verification, determination of radiation isocentre size, multileaf collimator (MLC) check and determination of isocentric shift for stereotactic radiosurgery (SRS) were performed and compared with film. The maximum variation observed between CR and film was 0.4 mm for field size verification, −0.13 mm for the radiation isocentre size check, 0.77 for MLC check and −0.1 mm for isocentric shift using the Winston Lutz test tool for SRS QA. From these results obtained with the CR it is concluded that a diagnostic CR system can be an excellent cost-effective digital alternative to therapy film as a tool for QA in radiotherapy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Langmack, K.A.,Portal imaging. Br J Radiol., 74(885): p. 789–804, 2001.

    CAS  PubMed  Google Scholar 

  2. Sonoda, M., Takano, M., Miyahara, J. and Kato, H.,Computed radiography utilizing scanning laser stimulated luminescence. Radiology, 148(3): p. 833–8, 1983.

    CAS  PubMed  Google Scholar 

  3. Wilenzick, R.M., C.R. Merritt, and S. Balter,Megavoltage portal films using computed radiographic imaging with photostimulable phosphors. Med Phys, 14(3): p. 389–92, 1987.

    Article  CAS  PubMed  Google Scholar 

  4. Gur, D., Deutsch, M., Fuhrman, C.R., Clayton, P.A., Weiser, J.C., Rosenthal, M.S. and Bukovitz, A.G.,The use of storage phosphors for portal imaging in radiation therapy: therapists’perception of image quality. Med Phys, 16(1): p. 132–6, 1989.

    Article  CAS  PubMed  Google Scholar 

  5. Whittington, R., Bloch, P., Hutchinson, D. and Bjarngard, B.E.,Verification of prostate treatment setup using computed radiography for portal imaging. J Appl Clin Med Phys, 3(2):p. 88–96, 2002.

    Article  PubMed  Google Scholar 

  6. Curtin-Savard, A.a.P., E.B.,An electronic portal imaging device as a physics tool, Med Dosim, 22(2): p. 101–5, 1997.

    Article  CAS  PubMed  Google Scholar 

  7. Dunscombe, P., Humphreys, S. and Leszczynski, K.,A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device. Med Phys, 26(2): p. 239–43, 1999.

    Article  CAS  PubMed  Google Scholar 

  8. Liu, G., van Doorn, T., and E. Bezak,The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID). Australas Phys Eng Sci Med., 27(3): p. 111–117, 2004.

    Article  CAS  PubMed  Google Scholar 

  9. Olch, A.J.,Evaluation of a computed radiography system for megavoltage photon beam dosimetry. Med Phys, 32(9): p.2987–99, 2005.

    Article  PubMed  Google Scholar 

  10. Seggern, H.V.,Photostimulable x-ray storage phosphors: a review of present understanding. Braz. J. Phys., 29(2): p. 254–268, 1999.

    Article  Google Scholar 

  11. Rasband, W.S.,ImageJ, U.S.N.I.o. Health, Editor, http://rsb.info.nih.gov/ij/: Bethesda, Maryland, USA, 2005.

  12. Gonzalez, A., Castro, I. and Martinez, J.A.,A procedure to determine the radiation isocenter size in a linear accelerator. Med Phys, 31(6): p. 1489–93, 2004.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to T. Peace.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Peace, T., Subramanian, B. & Ravindran, P. An experimental study on using a diagnostic computed radiography system as a quality assurance tool in radiotherapy. Australas. Phys. Eng. Sci. Med. 31, 226–234 (2008). https://doi.org/10.1007/BF03179349

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03179349

Key words

Navigation