Abstract
The use of binary thresholding for segmenting bone structures on spiral computed tomography images is negatively influenced by partial volume effects (PVEs) induced by the image acquisition. PVE leads to mixed voxels, making the binary decision “bone” or “non-bone” a difficult one to take. As a result, two distinct bone structures that are close to each other will often appear to be connected by this method. A typical example consists of “acetabulum/femural head” pairs in the pelvic region. To separate them, a clinical user must interactively draw a disarticulation line. This procedure is time consuming (often interaction in 50 slices is needed) and leads to unsmooth visualization of the disarticulated areas (by three-dimensional [3D] rendering techniques). We developed a semiautomatic cutting algorithm that leads to smooth disarticulated surfaces and considerably decreases the amount of user interaction. A sheet detection operator is applied to automatically separate bone structures. Detected sheets are used as disarticulation lines. Postprocessing ensures that sheets not relevant for the application do not influence the resulting image. Our approach is encapsulated in an interactive segmentation environment based on thresholding and 3D connected-component labeling. Results are shown for pelvic region, wrist, and foot bone disarticulations.
Article PDF
Similar content being viewed by others
References
Fishman EK, and Ney DR: Computers for clinical practice and education in radiology, RadioGraphics 13:463–475, 1993
Crawford CR, Starshak RJ, Waisman RC: Three-dimensional display of mathematically disarticulated objects. Computer Assisted Radiology Conference, Berlin, Germany, July 1989
Gerber JD, Magid D, Fishman EK: Simulated femoral repositioning with three-dimensional CT. J Comput Assist Tomogr 15:121–125, 1991
Ezrielev J, Dzik S: An image editor for 3d-CT reconstruction system. SPiE Medical Imaging IV, 1233:67–76, 1990
Mankovich NJ, White SC: The appearance of bony lesions on 3-D CT reconstructions: A case study in variable renderings. SPIE Image Capture Formatting Display 1653, 443–450, 1992
Kratka D, Van Cleynenbreugel J, Suetens P, et al: Binary bone segmentation: Problems and improvements. Pattern Recognition Image Anal 5:114–120, 1995
Canny J: Acomputational approach to edge detection. IEEE Trans Pattern Anal Machine Intelligence 8:679–698, 1986
Lacroix V: A three module strategy for edge detection. IEEE Trans Pattern Anal Machine Intelligence 10:803–810, 1988
Serra J: Image Analysis and Mathematical Morphology. London, UK, Academic, 1982
Van Cleynenbreugel J, Vandermeulen D, Smet M-H, et al: An interactive environment for efficient 3D segmentation and flexible 3D visualization. Laboratory for Medical Imaging Research. Leuven, Belgium, January 1995 (internal report)
Smet M-H, Marchal G, Suetens P: Medical model requirements and validation of medical models. PHIDIAs Mid Term Report Annex H, PHIDIAS Consortium, Leuven, Belgium, September 1994
Author information
Authors and Affiliations
Additional information
This work is part of PHIDIAS (laser photopolymerisation models based on medical imaging, a development improving the accuracy of surgery), Project No. BE/5930 of the Brite EuRam program of the European Comission. Participants in the PHIDIAS consortium are: Siemens AG, Erlangen, Germany; University of Leuven, Radiology and Electrical Engineering, Leuven, Belgium; Materialise NV, Heverlee, Belgium; and Zeneca Ltd, Cheshire, UK.
Rights and permissions
About this article
Cite this article
Van Cleynenbreugel, J., Kratka, D., Berben, L. et al. A semiautomatic three-dimensional segmentation method for disarticulation of bone structures on spiral computed tomography images. J Digit Imaging 8, 156–161 (1995). https://doi.org/10.1007/BF03168714
Issue Date:
DOI: https://doi.org/10.1007/BF03168714