Skip to main content
Log in

Comparing the performance of one-column process and four-zone simulated moving bed by computer simulation

  • Published:
Biotechnology and Bioprocess Engineering Aims and scope Submit manuscript

Abstract

A new one-column chromatography process, analogous to a four-zone simulated moving bed (SMB), was presented. The basic principle of the process was identical to that of a four-zone SMB. The process consisted of one chromatographic column and four tanks, instead of the four columns in the four-zone SMB (1-1-1-1), and has been used for the separation of two amino acids, phenylalanine and tryptophan, using an ion exchange resin. The operating parameters for the one-column process and four-zone SMB were obtained from equilibrium theory. Computer simulations were used to compare the performances of the new one column process to that of the general four-zone SMB, using Aspen Chromatography v 11.1. The differences between the one-column and SMB processes in terms of the purities and yields of phenylalanine and tryptophan were less than 4 and about 6%, respectively. The lower purities of the one-column process were due to the loss of the developed concentration profiles in the column when the liquid was stored in tanks. The one-column process gave great flexibility, and would be useful for reconstructing an existing conventional chromatography process to one of a SMB.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Broughton, D. B. (1968) Molex case history of a process.Chem. Eng. Prog. 64: 60–72.

    CAS  Google Scholar 

  2. Broughton, D. B., R. W. Neuzil, J. M. Pharis, and C. S. Brearley (1970) Parex process for recovering paraxylene.Chem. Eng. Prog. 66: 70–82.

    CAS  Google Scholar 

  3. Houwing, J., S. H. van Hateren, H. A. S. Billiet, and L. A. M. van der Wielen (2002) Effect of salt gradients on the separation of dilute mixtures of proteins by ion-exchange in simulated moving beds.J. Chromatogr. A. 952: 85–98.

    Article  CAS  Google Scholar 

  4. Wu, D., Y. Xie, Z. Ma, and N.-H. L. Wang (1998) Design of SMB chromatography for amino acid separations.Ind. Eng. Chem. Res. 37: 4023–4035.

    Article  CAS  Google Scholar 

  5. Xie, Y., D. Wu, Z. Ma, and N.-H. L. Wang (2000) Extended standng wave design method for simulated moving bed chromatography: linear systems.Ind. Eng. Chem. Res. 39: 1993–2005.

    Article  CAS  Google Scholar 

  6. Ching, C. B., K. H. Chu, K. Hidajat, and D. M. Ruthven (1993) Experimental study of a simulated counter-current adsorption system: VII. Effects of non-linear and interacting isotherms.Chem. Eng. Sci. 48: 1343–1445.

    Article  CAS  Google Scholar 

  7. Rodrigues, A. E., J. M. Loureiro, and L. S. Pais (1997) Separation of 1,1′-bi-2-naphthol enantiomers by continuous chromatography in simulated moving bed.Chem. Eng. Sci. 52: 25–35.

    Google Scholar 

  8. Wankat, P. C. (1994)Moving Bed and Simulated Moving Bed Sorption Separation: Rate-controlled Separations. Glasgow, London, UK.

  9. Yang, Y. J., S. H. Hwang, S. M. Lee, Y. J. Kim, and Y. M. Koo (2002) Continuous cultivation of lactobacillus rhamnosus with cell recycling using an acoustic cell settler.Biotechnol. Bioprocess Eng. 7: 357–361.

    Article  CAS  Google Scholar 

  10. Ching, C. B., K. H. Chu, K. Hidajat, and M. S. Uddin (1992) Comparative study of flow schemes for a simulated countercurrent adsorption separation process.AIChE J. 38: 1744–1750.

    Article  CAS  Google Scholar 

  11. Navarro, A., H. Caruel, L. Rigal, and P. Phemius (1997) Continuous chromatographic separation process: Simulated moving bed allowing simultaneous withdrawal of three fractions.Sep. Purif. Technol. 20: 39–50.

    Google Scholar 

  12. Ma, Z. and N.-H. L. Wang (1998) A nine-Zone simulating moving bed for the recovery of glucose and xylose from biomass hydrolyzate.Ind. Eng. Chem. Res. 37: 3699–3709.

    Article  Google Scholar 

  13. Ludemann-Homburger, O., R. M. Nicoud, and M. Bailly (2000) VARICOL process: A new multicolumn continuous chromatographic process.Sep. Sci. Technol. 35: 1829–1862.

    Article  Google Scholar 

  14. Migliorini, C., M. Wendlinger, M. Mazzotti, and M. Morbidelli (2001) Temperature gradient operation of a simulated moving bed unit.Ind. Eng. Chem. Res. 40: 2606–2617.

    Article  CAS  Google Scholar 

  15. Zang, Y. and P. C. Wankat (2002) SMB operation strategy- partial feed.Ind. Eng. Chem. Res. 41: 2504–2511.

    Article  CAS  Google Scholar 

  16. Storti, G., M. Mazzotti, M. Morbidelli, and S. Carra (2000) Robust design of binary counter-current adsorption separation processes.AIChE J. 46: 1384–1399.

    Article  Google Scholar 

  17. Mazzotti, M., G. Storti, and M. Morbidelli (1997) Operation of simulated moving bed units for nonlinear chromatographic separations.J. Chromatogr. A. 769: 3–24.

    Article  CAS  Google Scholar 

  18. Ma, Z. and N.-H. L. Wang (1997) Standing wave analysis of SMB chromatography: Linear systems.AIChE J. 43: 2488–2508.

    Article  CAS  Google Scholar 

  19. Row, K. H., C. H. Lee, and J. H. Kang (2002) Parameter estimation of perillyl alcohol in RP-HPLC by moment analysis.Biotechnol. Bioprocess Eng. 7: 11–16.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoon Mo Koo.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, Y.S., Lee, C.H., Wankat, P.C. et al. Comparing the performance of one-column process and four-zone simulated moving bed by computer simulation. Biotechnol Bioproc E 9, 362–368 (2004). https://doi.org/10.1007/BF02933058

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02933058

Keywords

Navigation