Abstract
A new one-column chromatography process, analogous to a four-zone simulated moving bed (SMB), was presented. The basic principle of the process was identical to that of a four-zone SMB. The process consisted of one chromatographic column and four tanks, instead of the four columns in the four-zone SMB (1-1-1-1), and has been used for the separation of two amino acids, phenylalanine and tryptophan, using an ion exchange resin. The operating parameters for the one-column process and four-zone SMB were obtained from equilibrium theory. Computer simulations were used to compare the performances of the new one column process to that of the general four-zone SMB, using Aspen Chromatography™ v 11.1. The differences between the one-column and SMB processes in terms of the purities and yields of phenylalanine and tryptophan were less than 4 and about 6%, respectively. The lower purities of the one-column process were due to the loss of the developed concentration profiles in the column when the liquid was stored in tanks. The one-column process gave great flexibility, and would be useful for reconstructing an existing conventional chromatography process to one of a SMB.
Similar content being viewed by others
References
Broughton, D. B. (1968) Molex case history of a process.Chem. Eng. Prog. 64: 60–72.
Broughton, D. B., R. W. Neuzil, J. M. Pharis, and C. S. Brearley (1970) Parex process for recovering paraxylene.Chem. Eng. Prog. 66: 70–82.
Houwing, J., S. H. van Hateren, H. A. S. Billiet, and L. A. M. van der Wielen (2002) Effect of salt gradients on the separation of dilute mixtures of proteins by ion-exchange in simulated moving beds.J. Chromatogr. A. 952: 85–98.
Wu, D., Y. Xie, Z. Ma, and N.-H. L. Wang (1998) Design of SMB chromatography for amino acid separations.Ind. Eng. Chem. Res. 37: 4023–4035.
Xie, Y., D. Wu, Z. Ma, and N.-H. L. Wang (2000) Extended standng wave design method for simulated moving bed chromatography: linear systems.Ind. Eng. Chem. Res. 39: 1993–2005.
Ching, C. B., K. H. Chu, K. Hidajat, and D. M. Ruthven (1993) Experimental study of a simulated counter-current adsorption system: VII. Effects of non-linear and interacting isotherms.Chem. Eng. Sci. 48: 1343–1445.
Rodrigues, A. E., J. M. Loureiro, and L. S. Pais (1997) Separation of 1,1′-bi-2-naphthol enantiomers by continuous chromatography in simulated moving bed.Chem. Eng. Sci. 52: 25–35.
Wankat, P. C. (1994)Moving Bed and Simulated Moving Bed Sorption Separation: Rate-controlled Separations. Glasgow, London, UK.
Yang, Y. J., S. H. Hwang, S. M. Lee, Y. J. Kim, and Y. M. Koo (2002) Continuous cultivation of lactobacillus rhamnosus with cell recycling using an acoustic cell settler.Biotechnol. Bioprocess Eng. 7: 357–361.
Ching, C. B., K. H. Chu, K. Hidajat, and M. S. Uddin (1992) Comparative study of flow schemes for a simulated countercurrent adsorption separation process.AIChE J. 38: 1744–1750.
Navarro, A., H. Caruel, L. Rigal, and P. Phemius (1997) Continuous chromatographic separation process: Simulated moving bed allowing simultaneous withdrawal of three fractions.Sep. Purif. Technol. 20: 39–50.
Ma, Z. and N.-H. L. Wang (1998) A nine-Zone simulating moving bed for the recovery of glucose and xylose from biomass hydrolyzate.Ind. Eng. Chem. Res. 37: 3699–3709.
Ludemann-Homburger, O., R. M. Nicoud, and M. Bailly (2000) VARICOL process: A new multicolumn continuous chromatographic process.Sep. Sci. Technol. 35: 1829–1862.
Migliorini, C., M. Wendlinger, M. Mazzotti, and M. Morbidelli (2001) Temperature gradient operation of a simulated moving bed unit.Ind. Eng. Chem. Res. 40: 2606–2617.
Zang, Y. and P. C. Wankat (2002) SMB operation strategy- partial feed.Ind. Eng. Chem. Res. 41: 2504–2511.
Storti, G., M. Mazzotti, M. Morbidelli, and S. Carra (2000) Robust design of binary counter-current adsorption separation processes.AIChE J. 46: 1384–1399.
Mazzotti, M., G. Storti, and M. Morbidelli (1997) Operation of simulated moving bed units for nonlinear chromatographic separations.J. Chromatogr. A. 769: 3–24.
Ma, Z. and N.-H. L. Wang (1997) Standing wave analysis of SMB chromatography: Linear systems.AIChE J. 43: 2488–2508.
Row, K. H., C. H. Lee, and J. H. Kang (2002) Parameter estimation of perillyl alcohol in RP-HPLC by moment analysis.Biotechnol. Bioprocess Eng. 7: 11–16.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, Y.S., Lee, C.H., Wankat, P.C. et al. Comparing the performance of one-column process and four-zone simulated moving bed by computer simulation. Biotechnol Bioproc E 9, 362–368 (2004). https://doi.org/10.1007/BF02933058
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02933058