Embolization of a high-output postnephrectomy aortocaval fistula with gianturco coils and cyanoacrylate

  • Technical Note
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

The authors describe the endovascular treatment of a high-output, large-caliber, postnephrectomy aortocaval fistula using a mixture of cyanoacrylate and lipiodol combined with Gianturco coil embolization. Thirtynine coils were used to decrease the flow through the fistula so that a fast-polymerizing glue mixture could be injected into the fistula. During rapid polymerization, the N-butyl-2-cyanoacrylate (NBCA) mixture was trapped within the coils, providing an easily controllable glue cast in the fistula, thereby preventing inadvertent embolization into the lungs. This approach can be of considerable benefit for the endovascular treatment of central high-output fistulas.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Malloy TR, LeBerman PR, Murphy JJ (1967) Renal arteriovenous fistula, J Urol 98: 40–43

    PubMed  CAS  Google Scholar 

  2. Goldstein AG, Delaurentis DA, Schwartz AJ (1967) Postnephrectomy arteriovenous fistula. J Urol 98: 44–47

    PubMed  CAS  Google Scholar 

  3. Cummings AG, Jolly PC, Graber JD, Burnett LL (1975) Arteriovenous fistula of the renal vessels: Surgical management. J Urol 114: 776–778

    PubMed  CAS  Google Scholar 

  4. Robinson DL, Teitelbaum GP, Pentecost MJ, Weaver FA, Finck EJ (1993) Transcatheter embolization of an aortocaval fistula caused by residual renal artery stump from previous nephrectomy: A case report. J Vasc Surg 17: 794–797

    Article  PubMed  CAS  Google Scholar 

  5. Grinnell VS, Flanagan KG, Mehringer CM, Hieshima GB (1983) Occlusion of large fistulas with detachable valved balloons and the spider. AJR 140: 1259–1261

    PubMed  CAS  Google Scholar 

  6. Maldonado JE, Sheps SG (1966) Renal arteriovenous fistula. Postgrad Med 40: 263–269

    PubMed  CAS  Google Scholar 

  7. Brothers MF, Kaufman JCE, Fox AJ, Deveikis JP (1989) N-butyl 2-cyanoacrylate substitute for IBCA in interventional neuroradiology: Histopathologic and polymerization time studies. AJNR 10: 777–786

    PubMed  CAS  Google Scholar 

  8. Ramchandani P, Goldenberg N, Soulen R, White R Jr (1983) IBCA embolization of a hepatoportal fistula. AJR 140: 137–140

    PubMed  CAS  Google Scholar 

  9. Redmond PL, Kumpe DA (1988) Embolization of an arterioportal fistula: Case report and review of the literature. Cardiovasc Intervent Radiol 11: 274–277

    PubMed  CAS  Google Scholar 

  10. Teng MM, Chen CC, Lirng JF, Chen SS, Chang T (1994) N-butyl-2-cyanoacrylate for embolization of carotid aneurysms. Neuroradiology 36: 144–147

    Article  PubMed  CAS  Google Scholar 

  11. Rao VRK, Mandalam KR, Grupta AK, Joseph S (1989) Dissolution of IBCA on long-term follow-up. AJNR 10: 135–142

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cekirge, S., Oguzkurt, L., Saatçi, I. et al. Embolization of a high-output postnephrectomy aortocaval fistula with gianturco coils and cyanoacrylate. Cardiovasc Intervent Radiol 19, 56–58 (1996). https://doi.org/10.1007/BF02560151

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02560151

Key words

Navigation