Abstract
Endovascular sealing with the Nellix® endoprosthesis (EVAS) is a new technique to treat infrarenal abdominal aortic aneurysms. We describe the use of endovascular sealing in conjunction with chimney stents for the renal arteries (chEVAS) in two patients, one with a refractory type Ia endoleak and an expanding aneurysm, and one with a large juxtarenal aneurysm unsuitable for fenestrated endovascular repair (EVAR). Both aneurysms were successfully excluded. Our report confirms the utility of chEVAS in challenging cases, where suprarenal seal is necessary. We suggest that, due to lack of knowledge on its durability, chEVAS should only been considered when more conventional treatment modalities (open repair and fenestrated EVAR) are deemed difficult or unfeasible.
Similar content being viewed by others
References
Donayre CE, Zarins CK, Krievins DK, Holden A, Hill A, Calderas C, Velez J, White RA. Initial clinical experience with a sac-anchoring endoprosthesis for aortic aneurysm repair. 1. J Vasc Surg. 2011;53:574–82. doi:10.1016/j.jvs.2010.09.009.
Krievins DK, Holden A, Savlovskis J, Calderas C, Donayre CE, Moll FL, Katzen B, Zarins CK. EVAR using the Nellix sac-anchoring endoprosthesis: treatment of favourable and adverse anatomy. Eur J Vasc Endovasc Surg. 2011;42(1):38–46. doi:10.1016/j.ejvs.2011.03.007.
Nellix, Instructions For Use, Copyright 2013, Endologix.
Truijers M, van Sterkenburg SM, Lardenoije JW, Reijnen MM. Endovascular repair of a ruptured pararenal aortic aneurysm using the nellix endovascular aneurysm sealing system and chimney grafts. 294. 2015;22(3):291.
Hughes CO, de Bruin JL, Karthikesalingam A, Holt PJ, Loftus IM, Thompson MM. Management of a type Ia Endoleak With the Nellix Endovascular Aneurysm Sealing System. J Endovasc Ther. 2015;22(3):309–11.
Böckler D, Reijnen MM, Krievins D, Peters AS, Hayes P, De Vries JP. Use of the Nellix EVAS system to treat post-EVAR complications and to treat challenging infrarenal necks. J Cardiovasc Surg (Torino). 2014;55(5):601–12.
Dijkstra ML, Lardenoye JW, van Oostayen JA, Zeebregts CJ, Reijnen MM. Endovascular aneurysm sealing for juxtarenal aneurysm using the Nellix device and chimney covered stents. J Endovasc Ther. 2014;21(4):541–7.
Malkawi AH, de Bruin JL, Loftus IM, Thompson MM. Treatment of a juxtarenal aneurysm with the Nellix endovascular aneurysm sealing system and chimney stent. J Endovasc Ther. 2014;21(4):538–40.
de Bruin JL, Yeung KK, Niepoth WW, Lely RJ, Cheung Q, de Vries A, Blankensteijn JD. Geometric study of various chimney graft configurations in an in vitro juxtarenal aneurysm model. J Endovasc Ther. 2013;20(2):184–90. doi:10.1583/1545-1550-20.2.184.
Niepoth WW, de Bruin JL, Lely RL, Wisselink W, de Vries JP, Yeung KK, Blankensteijn JD. In vitro feasibility of a sac-sealing endoprosthesis in a double chimney graft configuration for juxtarenal aneurysm. J Endovasc Ther. 2014;21(4):529–37.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
FT and RKF received proctorship fees from Endologix. FT and TYC received educational grants from Endologix. The authors declare no other conflict of interest.
Human and Animal Rights Statements
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed Consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Torella, F., Chan, T.Y., Shaikh, U. et al. ChEVAS: Combining Suprarenal EVAS with Chimney Technique. Cardiovasc Intervent Radiol 38, 1294–1298 (2015). https://doi.org/10.1007/s00270-015-1189-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-015-1189-x