Summary
The chromatographic properties of five columns packed with phenyl-bonded phases were characterized by an approach based on Tanaka's method for column to column comparisons in order to develop an LC analysis of partially methylated β-cyclodextrins. The retention behaviour of β-cyclodextrin, heptakis(2,6-di-O-methyl)-β-cyclodextrin and heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin was examined in order to evaluate the different interactions between phenyl stationary phase and this family of compound. Chromatograms show that the residual silanol activity of the packing materials plays a beneficial role in the partially methylated β-cyclodextrins separation process. It is concluded that knowledge of the interactions involved allows one to make a reasoned choice of the stationary phase in order to obtain the best possible analysis of three different commercial samples of partially methylated β-cyclodextrins.
Similar content being viewed by others
References
D. Duchene, in “Cyclodextrins and their industrial use”, D. Duchene, (Ed.), Edition de sante, Paris, 1987, chapter 8.
D. Sybilska, A. Bielejewska, R. Nowakowski, K. Duszczyk, J. Chromatogr. A.625, 349 (1992).
E. Szoko, J. Gyimesi, L. Barcza, K. Maggar J. Chromatogr. A745, 181 (1996).
I. Caron, A. Salvador, C. Elfakir, B. Herbreteau, M. Dreux, J. Chromatogr. A746, 103 (1996).
T. Loftsson, M. E. Brewster, Pharmaceutical Technology Europe9, 26 (1997).
J. Szemán, N. Roos, K. Csabai J. Chromatogr. A763, 139 (1997).
K. Koizumi, Y. Kubota, T. Utamura, S. Horiyama J. Chromatogr.368, 329 (1986).
Y. Kubota, T. Tanimoto, S. Horiyama, K. Koizumi, Carbohydr. Res.192, 159 (1989).
G. Schomburg, A. Deege, H. Hinrichs, E. Hübinger, H. Husmann, J. High Resolut. Chromatogr.15, 579 (1992).
A. Deege, H. Husmann, E. Hubinger, F. Kobor, G. Schomburg, J. High Resolut. Chromatogr.16, 587 (1993).
I. Caron, C. Elfakir, M. Dreux, J. Liq. Chrom. & Rel. Technol.20(7), 1123 (1997).
K. Kimata, K. Iwaguchi, S. Onishi, K. Jinno, R. Eksteen, K. Hosoya, M. Araki, N. Tanaka J. Chromatogr. Sci.27, 721 (1989).
M. J. Walters, J. Assoc. Off. Anal. Chem.70, 465 (1987).
H. Engelhardt, M. Jungheim, Chromatographia29, 59 (1990).
H. Engelhardt, H. Low, W. Gotzinger J. Chromatogr.544, 37 (1991).
H. A. Claessens, E. A. Vermeer, C. A. Cramers, LC/GC12, 114 (1994).
I. M. Mutton J. Chromatogr. A697, 191 (1995).
H. Tanaka, M. Kamada, M. Nyudo, M. Ohira J. Chromatogr.762, 89 (1997).
E. Cruz, M. R. Euerby, C. M. Johnson, C. A. Hackett, Chromatographia,44, 151 (1997).
A. Tchapla, S. Heron, E. Lesellier, H. Colin., J. Chromatogr. A656, 81 (1993).
C. Horvàth, W. Melander, I. Molnàr J. Chromatogr.125, 129 (1976).
A. Bielejewska, M. Kozbial, R. Nowakowski, K. Duszczyk, D. Sybilska, Anal. Chim. Acta300, 201 (1995).
K. Koizumi, Y. Kubota, Y. Okada, T. Utamura, S. Hizukuri, J.-I. Abe J. Chromatogr.437, 47 (1988).
A. K. Chatjigakis, Ph. J. P. Cardot, A. W. Coleman, H. Parrot-Lopez, Chromatographia36, 174 (1993).
A. Salvador, B. Herbreteau, M. Dreux, Analusis,25, 263 (1997).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Caron, I., Elfakir, C. & Dreux, M. Correlation between the chromatographic poperties of silica phenyl packing materials and the retention behaviour of methylated β-cyclodextrins. Chromatographia 47, 383–390 (1998). https://doi.org/10.1007/BF02466468
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02466468