Summary
A 65-year-old man was admitted with chest pain. A diagnosis of spastic angina was made because of symptoms of recurrent anginal attacks associated with ST-segment elevations in the electrocardiogram. A selective coronary arteriogram revealed a 90% diameter narrowing of the proximal left anterior descending coronary artery (LAD). No angiographically visible collaterals from the right coronary artery to the LAD were observed. The ventriculogram showed normal contraction of the left ventricle with an ejection fraction of 65%. Percutaneous transluminal coronary angioplasty (PTCA) failed resulting in total occlusion of the stenosis. Repeat PTCA at a higher pressure and of longer duration failed to redilate the artery. Reperfusion with the blood from the femoral artery through the balloon catheter, which was used for the PTCA, was carried out until coronary artery bypass grafting (CABG). Blood flow rate of perfusion was approximately 25 ml/min. Reperfusion through the balloon catheter reduced chest pain and ST-segment elevations in the electrocardiogram. The patient tolerated the operative procedure well and his post-operative course was uncomplicated. The interval between the acute occlusion and revascularization by CABG was approximately 4 1/4 h. The ventriculogram taken 56 days after the CABG demonstrated normal contraction of the anterior wall of the left ventricle with an ejection fraction of 63%. Abnormal Q waves did not appear in precordial leads of the electrocardiogram after the surgery. The thallium scintigram showed no perfusion defects.
In conclusion, this case suggested that autologous blood reperfusion through balloon cathether would be worth attempting in some cases for minimization of myocardial infarction during the interval between failed PTCA and emergency CABG.
Similar content being viewed by others
References
Gruentzig AR, Senning A, Siegenthaler WE (1979) Non-operative dilations of coronary-artery stenosis: percutaneous transluminal coronary angioplasty. N Engl J Med 301: 61–68
Dorros G, Cowley MJ, Simpson J, Bentivoglio LG, Block PC, Bourassa M, Detre K, Gosselin AJ, Gruenzig AR, Kelsey SF, Kent KM, Mock MB, Mullin SM, Myler RK, Passamani ER, Stertzer SH, Williams DO (1983) Percutaneous transluminal coronary angioplasty: report of complications from the National Heart, Lung, and Blood Institute PTCA Registry. Circulation 67: 723–730
Dorros G, Cowley MJ, Janke L, Kelsey SF, Mullin SM, Van Raden M (1984) In-hospital motality rate in the National Heart, Lung, and Blood Institute percutaneous transluminal coronary angioplasty registry. Am J Cardiol 53: C17-C21
Mulphy DA, Craver JM, Jones EL, Curling PE, Guyton RA, King SB, Gruentzig AR, Hatcher CR (1984) Surgical management of acute myocardial ischemia following percutaneous transluminal coronary angioplasty: role of the intra-aortic balloon pump. J Thorac Cardiovasc Surg 87: 337–339
Reul GJ, Cooley DA, Hallman GL, Duncan JM, Livesay JJ, Frazier OH, Ott DA, Angelini P, Massumi A, Mathur VS (1984) Coronary artery bypass for unsuccessful percutaneous transluminal coronary angioplasty. J Thorac Cardiovasc Surg 88: 685–694
Golding LAR, Loop FD, Hollman JL, Franco I, Borsh J, Stewart RW, Lytle BW (1986) Early results of emergency surgery after coronary angioplasty. Circulation 74 (Suppl III): 26–29
Leimgruber PP, Roubin GS, Hollman JH, Cotsonis GA, Meier B, Douglas JS, King SB, Gruentzig AR (1986) Restenosis after successful coronary angioplasty in patients with single-vessel disease. Circulation 73: 710–717
Marquis JF, Schwartz L, Aldridge H, Majid P, Henderson M, Matushinsky E (1984) Acute coronary artery occlusion during percutaneous transluminal coronary angioplasty treated by redilation of the occluded segment. J Am Coll Cardiol 4: 1268–1271
Jennings RB, Baum JH, Herdson PB (1965) Fine structural changes in myocardial ischemic injury. Arch Path Lab Med 79: 135–143
Gruentzig A (1976) Perkutane Dilatation von Coronarstenosen—Beschreibung eines neuen Kathetersystems. Klin Wschr 54: 543–545
King SB, III Douglas JS Jr (1982) Coronary arteriography and angioplasty. McGraw-Hill, New York, pp 451–453
Anderson HV, Leimgruber PP, Roubin GS, Nelson DL, Gruentzig AR (1985) Distal coronary artery perfusion during percutaneous transluminal coronary angioplasty. Am Heart J 110: 720–726
Timmis AD, Griffin B, Crick JCP, Sowton E (1987) Arterial blood infusion for myocardial protection during percutaneous transluminal coronary angioplasty. Eur Heart J 8: 340–346
McKeever WP, Gregg DE, Canney PC (1958) Oxygen uptake of nonworking left ventricle. Cir Res 6: 612–623
Hamby RI, Aintablian A, Handler M, Volety C, Weisz D, Garvey J, Wisoff G (1979) Aortocoronary saphenous vein bypass grafts: Long-term patency, morphology and blood flow in patients with patent grafts early after surgery. Circulation 60: 901–909
Chierchia S, Brunelli C, Simonetti I, Lazzari M, Maseri A (1980) Sequence of events in angina at rest: Primary reduction in coronary flow. Circulation 61: 759–768
Hinohara T, Simpson JB, Phillips HR, Behar VS, Peter RH, Kong Y, Carlson EB, Stack RS (1986) Transluminal catheter reperfusion: A new technique to reestablish blood flow after coronary occlusion during percutaneous transluminal coronary angioplasty. Am J Cardiol 57: 684–686
Ferguson TB, Hinohara T, Simpson J, Stack RS, Wechsler AS (1986) Catheter reperfusion allow optimal coronary bypass grafting following failed transluminal coronary angioplasty. Ann Thorac Surg 42: 399–405
Lehmann KG, Atwood JE, Snyder EL, Ellison RL (1987) Autologous blood perfusion for myocardial protection during coronary angioplasty: a feasibility study. Circulation 76: 312–323
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kusachi, S., Takata, S., Iwasaki, K. et al. Reperfusion through balloon catheter to minimize myocardial infarction during the interval between failed percutaneous transluminal coronary angioplasty and emergency coronary artery bypass grafting. Heart Vessels 5, 59–63 (1989). https://doi.org/10.1007/BF02058361
Received:
Revised:
Accepted:
Issue Date: