Summary
In thirty patients with extrahepatic cholestasis because of a malignant tumor a permanent bile duct endoprosthesis was inserted nonsurgically. As prosthesis a teflon tube (OD/ID 4.0/3.0 mm) was used without side holes (13 cases) or with side holes (17 cases). The bile was drained through the endoprosthesis during a period of 1–32 weeks. The drainage function of the endoprosthesis without side holes was classified as partially effective in seven cases and as insufficient in six cases. The drainage function of the endoprosthesis with side holes was judged as optimal in four cases, partially effective in ten and insufficient in three cases. The dysfunction of the endoprosthesis in nine of thirty cases was caused by lack of side holes, spontaneous occlusion or spontaneous dislocation of the prosthesis. Eight patients developed symptoms of cholangitis. In four cases sepsis occurred after insertion of the prosthesis. One patient died from the sequelae of an intrahepatic pseudoaneurysm, which had developed from a damaged segmental artery following the transhepatic bile drainage.
Zusammenfassung
30 Patienten mit extrahepatischer Cholestase aufgrund eines malignen Tumors erhielten eine permanente, percutan-transhepatisch eingesetzte Gallengangs-Endoprothese. Als Prothese wurde ein Teflon-Tubus (AD/ID 4,0/3,0 mm) ohne Seitenlöcher (13 Fälle) oder mit Seitenlöchern (17 Fälle) verwandt. Die Dauer der Gallendrainage durch die Endoprothese betrug 1– 32 Wochen. Die Drainagefunktion der Endoprothese ohne Seiten öcher wurde als partiell effektiv in 7 Fällen und als insuffizient in 6 Fällen Vorgetragen auf der 61. Tagung der Deutschen Röntgengesellschaft, Köln, 15.-17. Mai 1980 eingestuft. Die Drainagefunktion der Endoprothese mit Seitenlöchern wurde als optimal in 4 Fällen, als partiell effektiv in 10 und als insuffizient in 3 Fällen bewertet. Die Dysfunktion der Endoprothese in 9 von 30 Fällen war auf fehlende Seitenlöcher, spontanen Verschluß oder spontanes Gleiten der Prothese zurückzuführen. 8 Patienten entwickelten Symptome einer Cholangitis. In vier Fällen trat eine Sepsis nach Einsetzen der Prothese auf. Ein Patient starb an den Folgen eines intrahepatischen Pseudo-Aneurysmas, das sich nach Läsion einer Segmentarterie als Folge der transhepatischen Drainage entwickelt hatte.
Similar content being viewed by others
Literatur
Burcharth, F., Ingemann Jensen, L., Olesen, K.: Endoprosthesis for internal drainage of the biliary tract. Technique and results in 48 cases. Gastroenterology77, 133–137 (1979)
Ferrucci, J. T., Mueller, P. R., Harbin, W. P.: Percutaneous transhepatic biliary drainage. Technique, results and applications. Radiology135, 1–13 (1980)
Hansson, J. A., Hoevels, J., Simert, G., Tylén, U., Vang, J.: Clinical aspects of nonsurgical percutaneous transhepatic bile drainage in obstructive lesions of the extrahepatic bile ducts. Ann. Surg.189, 58–61 (1979)
Hellekant, C., Jonsson, K., Genell, S.: Percutaneous internal drainage in obstructive jaundice. Am. J. Roentgenol.134, 661–664 (1980)
Hoevels, J., Lunderquist, A., Ihse, I.: Percutaneous transhepatic intubation of bile ducts for combined internal-external drainage in preoperative and palliative treatment of obstructive jaundice. Gastrointest. Radiol.3, 23–31 (1978)
Hoevels, J., Ihse, I.: Percutaneous transhepatic insertion of a permanent endoprosthesis in obstructive lesions of the extrahepatic bile ducts. Gastrointest. Radiol.4, 367–377 (1979)
Hoevels, J., Nilsson, U.: Intrahepatic vascular lesions following percutaneous transhepatic bile duct intubation. Gastrointest. Radiol.5, 127–135 (1980)
Hoevels, J., Lunderquist, A., Owman, T., Ihse, I.: A large-bore teflon endoprosthesis with side holes for nonoperative decompression of the biliary tract in malignant obstructive jaundice. Gastrointest. Radiol.5, 361–366 (1980)
Jander, H. P.: Internal biliary drainage stent extension through slip joint coupling. Am. J. Roentgenol.135, 187–189 (1980)
Lunderquist, A., Lunderquist, M., Owman, T.: Guide wire for percutaneous transhepatic cholangiography. Radiology132, 228 (1979)
Mendez, G., Jr., Russel, E., Levi, J. U., Koolpe, H., Cohen, M.: Percutaneous brush biopsy and internal drainage of biliary tree through endoprosthesis. Am. J. Roentgenol.134, 653–659 (1980)
Mondcn, M., Okamura, J., Kobayashi, N., Shibata, N., Horikawa, S., Fiyimoto, T., Kosaki, G., Kuroda, Ch., Uchida, H.: Hemobilia after percutaneous transhepatic biliary drainage. Arch. Surg.115, 161–164 (1980)
Pollock, Th. W., Ring, E. R., Oleaga, J. A., Freiman, D. B., Mullen, J. L., Rosato, E. F.: Percutaneous decompression of benign and malignant biliary obstruction. Arch. Surg.114, 148–151 (1979)
Pereiras, R. V., Jr., Rheingold, O. J., Hutson, S., Mejia, J., Viamonte, M., Chiprut, R. O., Schiff, E. R.: Relief of malignant obstructive jaundice by percutaneous insertion of a permanent prosthesis in the biliary tree. Ann. Int. Med.89, 589–593 (1978)
Rupp, N., Weiss, H. D.: Perkutan eingebrachte Gallengangsprothesen als Primärmaßnahme bei Verschlußikterus. Fortschr. Röntgenstr.133, 279–284 (1980)
Sjövall, S., Hoevels, J., Sundquist, K.: Fatal outcome from emergency embolization of an intrahepatic aneurysm: A case report. Surgery87, 347–350 (1980)
Terblanche, J., Saunders, S. J., Louw, J. H.: Prolonged palliation in carcinoma of the main hepatic duct junction. Surgery71, 720–731 (1972)
Tylén, U., Hoevels, J., Vang, J.: Percutaneous transhepatic cholangiography with external drainage of obstructive biliary lesions. Surg. Gynecol. Obstet.114, 13–18 (1977)
Author information
Authors and Affiliations
Additional information
Vorgetragen auf der 61. Tagung der Deutschen Röntgengesellschaft, Köln, 15.–17. Mai 1980
Rights and permissions
About this article
Cite this article
Hoevels, J., Ihse, I., Lunderquist, A. et al. Erfahrungen mit einer percutan-transhepatisch eingesetzten Gallengangs-Endoprothese. Langenbecks Arch Chiv 354, 55–68 (1981). https://doi.org/10.1007/BF01834017
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01834017