Forced convection heat transfer from a flat-plate model collector on roof of a model house

Konvektiver Wärmeübergang von Flachplatten-Kollektoren auf den Dächern von Wohnhäusern im Modellversuch

  • Published:
Wärme - und Stoffübertragung Aims and scope Submit manuscript

Abstract

Presented in this abstract are the considerations and results of an investigation of forced convective heat loss from the surface of flat-plate model collectors flush mounted on the roof of a model residential house. Forced convection with air as the external fluid was treated.

The study was motivated by the need to better understand heat transfer from the top surface of flat-plate solar energy collectors. The experimental work dealt with heat transfer from the top of rectangular parallelpipeds flush mounted on roof of a model residential house. The smallest collector was 7.62×10−2 m long by 7.62×10−2 m wide by 3.3×10−2 m deep, and the largest collector was 15.875×10−2 m long by 15.875×10−2 m wide by 3.3×10−2 m deep. These small scale units are expected to simulate heat loss pattern from a flat-plate solar collector placed over the roof of a residential dwelling. Experiments were performed to determine the average heat transfer coefficients for forced convective air flow over the surface of the model collector which was inclined and yawed relative to the incoming air flow. The wind speeds varied approximately from 2.5 m/sec to 15 m/sec, the flow was laminar for all wind speeds.

Zusammenfassung

Es werden Vorüberlegungen und Ergebnisse bezüglich einer Untersuchung mitgeteilt, deren Ziel es war, die Wärmeverluste infolge Zwangskonvektion von Flachplatten-Kollektoren auf den Dächern von Wohnhäusern im Kleinmodell zu bestimmen. Angeregt wurde die Studie durch den Bedarf an genaueren Berechnungsunterlagen für den Wärmeübergang an Flachplatten-Solarkollektoren. Die für das Experiment verwendeten zwei Kollektoren waren quadratisch, mit den Seitenlägen 7,62 bzw. 15,9 cm, bei jeweils 3,3 cm Tiefe. Die Versuche lieferten unter Zwangskonvektion mittlere Wärmeübergangskoeffizienten an den Oberflächen der Modellkollektoren, welche zur ankommenden Luftströmung sowohl geneigt als auch gedreht orientiert waren. Bei laminarer Strömung lagen die Anströmgeschwindigkeiten zwischen 2,5 and 15 m/s.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Duffie, J. A.; Beckmann, W. A.: Solar energy thermal processes. New York: John Wiley and Sons, Inc. 1974

    Google Scholar 

  2. Saying, A. H.: Solar energy engineering. New York: Academic Press 1977

    Google Scholar 

  3. Kreith, F.; Kreider, J. E.: Principles of solar engineering. New York: McGraw Hill 1978

    Google Scholar 

  4. Results and analysis of a round robin test program for liquid heating flat plate solar collector, NBS, Washington D.C.; TN, 1975; August 1978

  5. Meinel, A. B.; Meinel, M. P.: Applied solar energy. New York: Prentice Hall 1976

    Google Scholar 

  6. McAdams, W. H.: Heat transmission. New York: McGraw Hill 1954

    Google Scholar 

  7. Sparrow, E. M.; Tien, K. K.: Forced convection heat transfer at an inclined and yawed square plate-application to solar collectors. ASME J. of Heat Transfer 99 (1977) 507–512

    Google Scholar 

  8. Rowley, F. B.; Eckley, W. A.: Surface coefficients as affected by direction of wind. Heating, Piping and Air-conditioning Journal, October (1931) 870–874

  9. Sogin, H. H.: A summary of experiments of local heat transfer from the rear of bluff obstacles to a low speed air-stream. ASME J. of Heat Transfer 86C (1964) 200–202

    Google Scholar 

  10. Parmelee, G. V.; Huebscher, R. G.: Forced convection heat transfer from flat surfaces. Transactions American Society of Heating and Ventilating Engineers 53 (1947) 245–284

    Google Scholar 

  11. Kind, R. J.; Gladstone, P. H.; Mozier, A. D.: Convective heat losses flat plate solar collectors in turbulent winds. ASME J. Solar Energy Engineering 105 (1983) 80–85

    Google Scholar 

  12. Kind, R. J.; Kitaljevich, D.: Wind induced heat losses from solar collector arrays on flat-roofed buildings. ASME J. of Solar Energy Engineering 107 (1985) 335–342

    Google Scholar 

  13. Characteristics of wind speed in the lower layers of the atmosphere near the ground: Strong Winds, Engineering Sciences Data Unit, ESDU Data Item No: 72026, London, 1972

  14. Arpaci, V. S.; Larsen, P. S.: Convection heat transfer. Prentice Hall 1984

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Onur, N. Forced convection heat transfer from a flat-plate model collector on roof of a model house. Warme - und Stoffubertragung 28, 141–145 (1993). https://doi.org/10.1007/BF01541111

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01541111

Keywords

Navigation