Abstract

The electrostatic magnetic energy analyzer consists of a Wien filter (crossed electric and magnetic fields) between two immersion lenses. The energetic resolution of the analyzer is calculated. The intensity problem in connection with the generation of a monoenergetic electron beam is discussed considering anomalous energy spread in high density beams. With an arrangement containing two analyzers of the same kind the resolving power is experimentally determined to 0.017 ev.