Abstract
The effective dose equivalent, HE, can be used as a standard radiation dose parameter in all imaging modalities that use ionizing radiation, including positron emission tomography (PET). A simplified method for evaluating approximate HE values for the positron emitters carbon 11, nitrogen 13, oxygen 15 and fluorine 18 is presented. HE values for a range of PET studies have been computed based on biodistribution data available in the scientific literature. Low-dose PET studies include a bolus administration of 1030 MBq CO15O (HE = 1 mSv) and 74 MBq [18F]-l dopa (HE = 1.3 mSv). High-dose PET studies include a 1-h (steady-state) inhalation of a total of 9250 MBq C15OO (HE = 9.4 mSv). The mean HE value of 13 diverse PET studies was computed to be 4.5 mSv.
Similar content being viewed by others
References
Allan RM, Horlock PL, Pike VW, Jones T, Selwyn AP (1981) Myocardial ischemia: detection and investigation. In: Unstable angina pectoris. International symposium, Hannover, 1980. Georg Thieme, Stuttgart New York, pp 45–51
Bigler RE, Sgouros G (1983) Biological analysis and dosimetry for15O-labelled O2 CO2, and CO gases administered continuously by inhalation. J Nucl Med 24:431–437
Dillman LT, Van der Lage FC (1975) Radionuclide decay schemes and nuclear parameters for use in radiation-dose estimation. Nuclear medicine/medical internal radiation dosimetry pamphlet 10. Society of Nuclear Medicine, New York
Harvey J, Firnau G, Garnett ES (1985) Estimation of the radiation dose in man due to 6-[18F]fluoro-l-dopa. J Nucl. Med 26:931–935
Hubner KF, Andrews GA, Buonocore E, Hayes RL, Washburn LC, Collman R, Gibbs WD (1979) Carbon-11-labelled amino acids for the rectilinear and positron tomographic imaging of the human pancreas. J Nucl Med 20:507–513
Huda W, Gordon K (1989) Nuclear medicine staff and patient doses in Manitoba (1981–1985). Health Phys 56:277–285
Huda W, Sandison GA (1989) The use of the effective dose equivalent, HE, for99mTc labelled radiopharmaceuticals. Eur J Nucl Med 15:174–179
Huda W, Scrimger JW (1989) Irradiation of volunteers in nuclear medicine. J Nucl Med 30:260–264
Huda W, Sandison GA, Lee TY (1989a) Patient doses from computed tomography in Manitoba from 1977 to 1987. Br J Radiol 62:138–144
Huda W, Lentle B, Sutherland JB (1989b) The effective dose equivalent in radiology (editorial). J Can Assoc Radiol 40:3–4
International Commission on Radiological Protection (1975) Report of the Task Group on Reference Man. ICRP publication 23. Pergamon Press, Oxford
International Commission on Radiological Protection (ICRP) (1977) Recommendations. ICRP publication 26. Pergamon Press, Oxford
International Commission on Radiological Protection (1987) Radiation doses to patients from radiopharmaceuticals. ICRP publication 53. Ann ICRP 18:1–4
Johansson L (1985) Patient irradiation in diagnostic nuclear medicine. Assessment of absorbed dose equivalent and effective dose equivalent. PhD Thesis, University of Goteburg
Johansson L, Mattsson S, Nosslin B (1984) Effective dose equivalent from radipharmaceuticals. Eur J Nucl Med 9:485–489
Jones SC, Alavi A, Christman D, Montanez I, Wolf AP, Reivich M (1982) The radiation dosimetry of 2-[F-18]fluoro-2-deoxy-d-glucose in man. J Nucl Med 23:613–617
Junker D, Fitschen J (1988) Spezielle Probleme des Strahlenschutzes. In: Fitschen J, Helus F, Jordan K, Junker D, Meyer GJ, Schober O, Stocklin G (eds), Nuclear medicine: emission computer tomography with short lived cyclotron produced radiopharmaceuticals. (Encyclopedia of medical radiology, vol XV/1b) Springer, Berlin Heidelberg New York, pp 119–147
Kearfott KJ (1982) Absorbed dose estimates for positron emission tomography (PET): C15O,11CO, and CO15O. J Nucl Med 23:1031–1037
Kearfott KJ, Junck L, Rottenberg DA (1983) C-11 dimethyloxazolidinedione (DMO): biodistribution, radiation absorbed dose, and potential for PET measurement of regional brain pH: concise communication. J Nucl Med 24:805–811
Kereiakes JG, Rosenstein M (1980) Handbook of radiation doses in nuclear medicine and diagnostic X-ray. CRC Press, Boca Raton, Florida, pp 61–98
Maccia C, Benedittini M, Lefaure C, Fagnani F (1988) Doses to patients from diagnostic radiology in France. Health Phys 54:397–408
Powell GF, Chen Chin-Tu (1987) Radiation absorbed dose to bladder walls from positron emitters in the bladder content. Med Phys 14:1079–1086
Shrimpton PC, Wall BF, Jones DG, Fisher ES, Hillier MC, Kendall GM, Harrison RM (1986) A national survey of dose to patients undergoing a selection of routine X-ray examinations in English hospitals. National Radiological Protection Board (NRPB) report R200. Didcot, Chilton
Tillisch J, Brunken R, Marshall R, Schwaiger M, Mandelkern M, Phelps M, Schelbert H (1986) Reversibility of cardiac wall-motion abnormalities predicted by positron tomography. New Engl J Med 314:884–888
United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) (1982) Report to the General Assembly. UN, New York, p 334
Vano E, Gonzalez L, Calzado A, Moran P, Delgado V (1989) Some indicative parameters on diagnostic radiology in Spain: first dose estimations. Br J Radiol 62:20–26
Wong DF, Bice AN, Beck T, Dannals RF, Links JM, Wagner HN Jr (1986) Dosimetry calculations for the neuroreceptor binding radiotracer C-11N-methylspiperone (abstract) J Nucl Med 27:898
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Huda, W., Sandison, G.A. Estimates of the effective dose equivalent, HE, in positron emission tomography studies. Eur J Nucl Med 17, 116–120 (1990). https://doi.org/10.1007/BF00811437
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF00811437