Abstract
In order to automate measurements of cell concentration and viability in a suspended animal cell culture, we have developed anin situ microscopic image analysis system with an effective cell recognition algorithm. With a small amount of sample, this system can measure the cell density rapidly and aseptically. In addition, it can measure a cell size histogram including cell debris small particle distribution. These small particles have been found to be related to the viability of the mouse-mouse hybridoma STK1 cell line. By using cell debris small particle density as an indicator of cell viability, the developed system provides non-destructive viability monitoring without trypan blue staining.
Similar content being viewed by others
References
Bradbury S (1979) Microscopical Image Analysis: Problems and Approaches. J. Microsc. 115: 137–150.
Broise Ddl, Noiseux M, Lemieux R & Massie B (1991) Long-Term Perfusion Culture of Hybridoma: A “Grow or Die” Cell Cycle System. Biotechnol. Bioeng. 38: 781–787.
Brooks RF & Shields R (1985) Cell Growth, Cell Division and Cell Size Homeostasis in Swiss 3T3 Cells. Exp. Cell Res. 156: 1–6.
Chuck AS & Palsson BO (1992) Population Balance between Producing and Nonproducing Hybridoma Clones Is very Sensitive to Serum Level, State of Inoculum, and Medium Composition. Biotechnol. Bioeng 39: 354–360.
Frame KK & Hu W-S (1990) Cell Volume Measurement as an Estimation of Mammalian Cell Biomass. Biotechnol. Bioeng. 36: 191–197.
Goebel NK, Kuehn R & Flickinger MC (1990) Methods for Determination of Growth-Rate-Dependent Changes in Hybridoma Volume, Shape and Surface Structure during Continuous Recycle. Cytotechnol. 4: 45–57.
Livne A, Grinstein S & Rothstein A (1987) Volume-Regulating Behavior of Human Platelets J. Cell. Physiol. 131: 354–363.
Miller SJO, Henrotte M & Miller AOA (1986) Growth of Animal Cells on Microbeads. I.In situ Estimation of Numbers. Biotechnol. Bioeng 28: 1466–1473.
Pons M-N, Wagner A, Vivier H & Marc A (1992) Application of Quantitative Image Analysis to a Mammalian Cell Line Grown on Microcarriers. Biotechnol. Bioeng. 40: 187–193.
Resau JH & Trup BF (1988) Cell Injury, Differentiation, and Regeneration in Explant, Organ, and Cell Culture Models. In: Advances in Cell Culture. Vol. 6 (pp. 261–289) Academic Press, Inc., London.
Rudt S, Blunk T & Müller RH (1992) Quantification of Cell Subpopulations, Fractions of Dead Cells and Debris in Cell Suspensions by Laser Difractometry. Pharm. Ind. 54: 966–969.
Sen S, Srienc F & Hu W-S (1989) Distinct Volume Distribution of Viable and Non-Viable Hybridoma Cells: A Flow Cytometric Study. Cytotechnol. 2: 85–94.
Shields R, Brooks RF, Riddle PN, Capellaro DF & Delia D (1978) Cell Size, Cell Cycle and Transition Probability in Mouse Fibroblasts. Cell 15: 469–474.
Tucker KG, Chalder S, Al-Rubeai M, Thomas CR (1994) Measurement of Hybridoma Cell Number, Viability, and Morphology Using Fully Automated Image Analysis. Enzyme Microb. Technol. 16: 29–35.
Wheatley DN, Inglis MS & Foster MA (1987) Hydration, Volume Changes and Nuclear Magnetic Resonance Proton Relaxation Times of Hela S-3 Cells in M-Phase and the Subsequent Cell Cycle. J. Cell Sci. 88: 13–23.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Maruhashi, F., Murakami, S. & Baba, K. Automated monitoring of cell concentration and viability using an image analysis system. Cytotechnology 15, 281–289 (1994). https://doi.org/10.1007/BF00762403
Issue Date:
DOI: https://doi.org/10.1007/BF00762403