Abstract
Our purpose was the comparison of T1-weighted spin-echo (SE) and three-dimensional (3D) Turbo-fast low-angle shot (FLASH) (3DTFL) in detection of 14 pituitary microadenomas following intravenous gadolinium (Gd). 3DTFL represents an important improvement in the diagnosis of pituitary microadenomas. In two cases, the site of the tomour was correctly identified only by Gd-enhanced Turbo-FLASH. Nevertheless, in two other cases, the Gd-enhanced 3DTFL gave false negative (FN) results while the T1-weighted SE images enabled correct localisation. Replacement of T1-weighted SE by 3DTFL cannot therefore be advocated and use of both contrast-enhanced sequences of-fers the highest detection capability for microadenomas.
Similar content being viewed by others
References
Peck WW, Dillon WP, Norman D, Newton TH, Wilson CB (1989) High-resolution MR imaging of pituitary microadenomas at 1.5 T: experience with Cushing disease. AJR 152: 145–151
Nichols DA, Laws ER, Houser OW, Abboud CF (1988) Comparison of magnetic resonance imaging and computed tomography in the preoperative evaluation of pituitary adenomas. Neurosurgery 22: 380–385
Kucharczyk W, Davis DO, Kelly WM, Sze G, Norman D, Newton TH (1986) Pituitary adenomas: high-resolution MR imaging at 1.5 T. Radiology 161: 761–765
Kulkarni MV, Lee KF, McArdle CB, Yeakley JW, Haar FL (1988) 1.5 T imaging of pituitary microadenomas: technical considerations and CT correlations. AJNR 9: 5–11
Davis PC, Hoffman JC, Malko JA, et al (1987) Gadolinium-DTPA and MR imaging of pituitary adenoma: a preliminary report. AJNR 8: 817–823
Doppman JL, Frank JA, Dwyer AJ, et al (1988) Gadolinium DTPA enhanced MR imaging of ACTH-secreting microadenomas of the pituitary gland. J Comput Assist Tomogr 12: 728–735
Dwyer AJ, Frank JA, Doppman JL, et al (1987) Pituitary adenomas in patients with Cushing disease: initial experience with Gd-DTPA-enhanced MR imaging. Radiology 163 421–426
Steiner VE, Wimberger D, Imhof H, Knosp E, Hajek P (1989) Gd-DTPA in MR diagnosis of pituitary adenomas. ROFO 150: 323–327
Pojunas KW, Daniels DL, Williams AL, Haughton VM (1986) MR imaging of prolactin-secreting microadenomas. AJNR 7: 209–213
Stadnik T, Stevenaert A, Beckers A, Luypaert R, Buisseret T, Osteaux M (1990) Pituitary microadenomas: diagnosis with
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Stadnik, T., D'Haens, J., Luypaert, R. et al. The value of three-dimensional turbo-FLASH and spin-echo sequences in the detection of pituitary microadenomas following gadolinium administration. Neuroradiology 36, 598–601 (1994). https://doi.org/10.1007/BF00600416
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00600416