Abstract
The results of a study comparing the ability of 99Tcm-sulphur colloid and 99Tcm-HIDA to demonstrate circumscribed defects and obstruction of the biliary flow to the intestines are reported. As regards focal liver diseases, colloid scintigraphy (SC) had a nosographic sensitivity and specificity of 0.87 and 0.85, respectively. The corresponding figures for the HIDA scintigraphy were 0.40 and 0.92. The sensitivities are significantly different. Concerning the diagnosis of extrahepatic obstruction, sulphur colloid scintigraphy had a nosographic sensitivity and specificity of 0.31 and 0.94. The corresponding figures for HIDA scintigraphy were 0.69 and 0.84. These sensitivities are significantly different too. The most frequent cause of false results was a pattern of hepatocellular disease in sulphur colloid scans in patients with a longstanding biliary obstruction. The second most frequent error was due to circumscribed defects in SC as well as in HIDA scans in patients with obstructive diseases and a high value of serum bilirubin. A third source of error was the pattern of an obstruction in HIDA scans in patients with focal diseases. The significance of the star pattern the sulphur colloid scan in patients with obstruction is stressed, as the significance of this pattern not has been evaluated previously. It is concluded that the two different scintigraphic methods are complementary tools in the examination of patients with liver diseases
Similar content being viewed by others
References
Biersack, H.J., Thelen, M., Knopp, R., Breul, H.-P., Winkler, C.: Funktionsszintigraphie der Leber und der Gallenwege mit 99mTc-Dieathylida. Fortschr. Röntgenstr. 127, 422–427 (1977)
Harvey, E., Loberg, M., Cooper, M.: Tc-99m-HIDA: A new radiopharmaceutical for hepatobilitary imaging. J. Nucl. Med. 16, 533–538 (1975)
Heck, L.L., Gottschalk, A.: The apperance of intrahepatic biliary duct dilatation on the liver scan. Nucl. Med. 99, 135–140 (1971)
McClelland, R.R.: Focal porta hepatis scintiscan defects: what is their significance? J. Nucl. Med. 16, 1007–1012 (1975)
Öster-Jörgensen, E., Pedersen S.A., Schoubye, J.: Hepatobiliary scintigraphy with 99Tcm-HIDA in patients with jaundice. Acta Radiol. 20, 299–310 (1979a)
Öster-Jörgensen, E., Simonsen, E., Henriksen, O.B.: Scintigraphy of liver and spleen with 99mTc-sulfur colloid and Anger camera. Danish Med. Bull. 26, 87–91 (1979b)
Reichelt, H.-G.: Die hepatobiliare Sequenz-Szintigraphie-Entwicklung, Methodik und Empfehlungen für die klinische Anwendung. Fortschr. Röntgenstr. 127, 427–433 (1977)
Reichelt, H.-G., Stender, H.-St., Schmidt, F.W., Hundeshagen, H.: Hepatobiliare Sequenzszintigraphie — Fortschritte in der Abklarung von Rest- und Nachbeschwerden Cholezystektomierter. Fortschr. Röntgenstr. 128, 451–459 (1978)
Tongendorff, J., Raithel, E., Bull, U., Grunts, J., Trumm, F., Scherer, R.: Die Wertigkeit der hepatobiliaren Funktionsszintigraphie mit 99mTc-Diethyl-IDA. Nucl. Med. 17, 30–40 (1978)
Wolf, von F., Krönert, E., Regler, G.: Nuclearmedizinische Diagnostik der Leber und Gallenwege mit 99mTc-markierten Verbindungen. Fortschr. Med. 96, 455–462 (1978)
Wright, F.W.: Scanning of the liver, spleen and pancreas. In: Topics in gastroenterology. 4. S.C. Truelove and J.A., Ritchie (eds.), pp. 195–211 Oxford: Blackwell Scientific Publications 1976
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Pedersen, S.A., Øster-Jørgensen, E. & Schoubye, J. Hepatobiliary scintigraphy with 99Tcm-HIDA and 99Tcm-sulphur colloid. Eur J Nucl Med 5, 305–309 (1980). https://doi.org/10.1007/BF00445615