Skip to main content
Log in

Vergleichende experimentelle Untersuchungen an Bioglas (L. L. Hench), Al2O3-Keramik und mit mod. Bioglas beschichteter Al2O3-Keramik

I. Ergebnisse mit unbelasteten Implantaten

Comparative experimental investigations with bioglass (L. L. Hench), Al2O3-ceramic and Al2O3-ceramic coated with a mod. bioglass

I. Results of experiments under non-loaded conditions

  • Originalarbeiten
  • Published:
Archiv für orthopädische und Unfall-Chirurgie, mit besonderer Berücksichtigung der Frakturenlehre und der orthopädisch-chirurgischen Technik Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Summary

This report deals with comparative results obtained with unloaded intra-osseous implants of bioglass (L. L. Hench), Al2O3-ceramic and Al2O3-ceramic coated with a mod. bioglass. Al2O3-ceramic and bone form a direct bony interface without fibrous tissue interposition, this resulting in a pure mechanic fixation of the implant through frictional forces of the surface roughed ceramic. Pure bioglass (45 S 5) and bone form a unique persisting direct interface by means of physico-chemical or biochemical phaenomena stabilizing the implant. Interface stability seams to be higher than the fatique strenth of the glass itself. This interface is developed as a consequence of solubility of some of the glass constituents within a surface layer of up to 200 microns, running parallel with a reduction of strength of this surface glass layer. The boronoxide containing bioglass, flame-sprayed onto Al2O3-ceramic samples seams to be less soluble and therefore seams to have lesser bonding capability to bone. The stability of the interface bioglass coating-Al2O3-ceramic was low.

Zusammenfassung

Es wird über vergleichende Untersuchungen zur Grenzflächenentwicklung um unbelastete intraossäre Implantate aus Bioglas (L. L. Hench), Al2O3-Keramik und mit modifiziertem Bioglas beschichteter Al2O3-Keramik berichtet. Zwischen Al2O3-Keramik und Knochen entsteht eine direkte bindegewebsfreie knöcherne Kontaktfläche, die infolge der mikroskopischen Rauhigkeit der Keramik eine mechanisch-verzahnende Haftung bewirkt. Zwischen dem reinen Bioglas (45 S 5) und Knochen entsteht eine außerordentlich halbare, durch physiko-chemische oder biochemische Phänomene stabilisierte Grenzfläche, deren Festigkeit höher ist als die des Glases selbst. Diese innige Bindung zwischen Glas und lebendem Knochen entsteht vermutlich auf Kosten einer breiten oberflächlichen Elution des Glases (Schicht etwa 100–200 μm dick), was mit einer Festigkeitsabnahme dieser oberflächlichen Glasschicht einhergeht. Das im Flammenspritzverfahren auf Al2O3-Keramik aufgebrachte boroxidhaltige Bioglas ist vermutlich geringer löslich und deshalb weniger bindungsfähig zum Knochen. Die Haftfestigkeit dieser Verbindung auf dem Keramikträger war gering.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Beckham, C. A., Greenlee, T. K., Crebo, A. R.: Bone formation at a ceramic implant interface. Calc. Tiss. Res. 8, 165–171 (1971)

    Google Scholar 

  • Blencke, B. A., Pfeil, E., Brömer, H.: Rasterelektronenmikroskopische Untersuchungen der Reaktion des Knochens auf glaskeramische Implantate. Z. Orthop. 112, 978–980 (1974a)

    Google Scholar 

  • Blencke, B. A., Allentsee, P., Brömer, H., Pfeil, E.: Untersuchungen über die Reaktion von Weichgeweben auf glaskeramische Implantate. Arch. orthop. Unfall-Chir. 82, 135–146 (1975)

    Google Scholar 

  • Blencke, B. A.: Persönl. Mitteilung (1977)

  • Boutin, P.: Arthroplastie totale de la hanche par prothèse en alumine frittée. Etude expérimentale et premières applications cliniques. Rev. chir. orthop. 58, 229–246 (1973)

    Google Scholar 

  • Boutin, P., Blanquaert, D., Ribonet, M.: Total hip arthoplasty by prosthesis using an alumina/alumina/titanium alloy combination with and without use of bone cement. Transactions Ann. Meeting Soc. Biomat. 1, 17 (1977)

    Google Scholar 

  • Brömer, H., Deutscher, K., Blencke, B., Pfeil, E.: Glaskeramiken für Osteoplastik und Osteosynthese. Zwischenbericht. Bundesmin. Forsch. Technol. NTÖ 26 1974

  • Clark, A. E., Hench, L. L., Paschall, H. A.: The influence of surface chemistry on implant interface histology. A theoretical basis for implant materials selection. J. Biomed. Mater. Res. 10, 161–174 (1976)

    Google Scholar 

  • Greenspan, D. C., Hench, L. L.: Chemical and Mechanical Behaviour of Bioglas coated Alumina. J. Biomed. Mater. Res. Symp. 7, 511–518 (1976)

    Google Scholar 

  • Griss, P., Andrian-Werburg, H. v., Krempien, B., Heimke, G.: Biological Activity and Histocompatibility of Dense Al2O3/MgO Ceramic Implants in Rats. J. Biomed. Mater. Res. Symp. 4, 453–462 (1973)

    Google Scholar 

  • Griss, P., Andrian-Werbung, H. v., Heimke, G.: Die Aluminiumoxidkeramik-Metall-Verbund-endoprothese. Eine neue Hüftgelenktotalendoprothese zur teilweise zementfreien Implantation. Arch. orthop. Unfall-Chir. 81, 259–266 (1975)

    Google Scholar 

  • Griss, P., Silber, R., Merkle, B., Haehner, K., Heimke, G., Krempien, B.: Biomechanically induced tissue reactions after Al2O3-ceramic hip joint replacement. Experimental and early clinical results. J. Biomed. Mater. Res. Symp. 7, 519–528 (1976)

    Google Scholar 

  • Griss, P., Heimke, G., Krempien, B., Jentschura, G.: Ceramic hip joint replacement. Experimental results and early clinical experience. Symp. Advances in Hip and Knee Technology, pp. 446–455. Berlin-Heidelberg-New York: Springer 1976

    Google Scholar 

  • Griss, P., Andrian-Werburg, H. v., Heimke, G., Krempien, B., Reipa, S., Hartung, H. J., Lauterbach, H. J.: Ergebnisse der experimentellen Prüfung und klinischen Anwendungsmöglichkeiten der Aluminiumoxydkeramik in der Alloarthroplastik. Z. Orthop. 113, 756–759 (1975)

    Google Scholar 

  • Griss, P., Heimke, G., Krempien, B., Silber, R., Haehner, K., Merkle, B.: Erste Erfahrungen mit der Keramik-Metall-Verbundprothese. Med. Orthop. Technik (MOT) 95, 159–162 (1975)

    Google Scholar 

  • Griss, P.: Die Aluminiumoxydkeramik — ein neuer Werkstoff für Endoprothesen. Ergebnisse der experimentellen Prüfung und erste klinische Anwendungen. Habilitationsschrift Univ. Heidelberg/Mannheim, 1976

    Google Scholar 

  • Griss, P., Werner, E., Buchinger, R., Heimke, G.: Die Mannheimer Oxidkeramik-Metall-Verbundendoprothesen. Eine kritische Wertung unserer bisherigen klinischen Erfahrungen. Arch. orthop. Unfall-Chir. 87, 73–84 (1977)

    Google Scholar 

  • Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: An investigation of bonding mechanisms at the interface of a prosthetic material. Report No. 1, US Army Med. Res. and Development Command, Contract No. DADA 17-70-C-0001 (1970)

  • Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: Report No. 2 (1971)

  • Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: Report No. 3 (1972)

  • Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: Report No. 4 (1973)

  • Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: Report No. 5 (1974)

  • Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: Report No. 6 (1975)

  • Hench, L. L., Paschall, H. A.: Histochemical responses of a Biomaterials interface. J. Biomed. Mater. Res. Symp. 5, 49–64 (1974b)

    Google Scholar 

  • Hench, L. L., Paschall, H. A., Allen, W. C., Piotrowski, G.: Interfacial behaviour of ceramic implants. Natl. Bureau Standards, Spez. Publ. No. 415, 19–36 (1975b)

  • Hench, L. L., Pantano, C. G., Buscemi, P. J., Greenspan, D. C.: Analysis of bioglass fixations of hip prostheses. J. Biomed. Mater. Res. 11, 267–282 (1977)

    Google Scholar 

  • Hulbert, S. F., Young, F. A., Mathews, R. S., Klawitter, J. J., Talbert, C. D., Stelling, F. H.: Potential of ceramic materials as permanently implantable skeletal prostheses. J. Biomed. Mater. Res. 4, 433–456 (1970)

    Google Scholar 

  • Predecki, P., Auslaender, B. A., Stephan, J. E., Mooney, V. L., Stanitzki, C.: Attachment of bone to threaded implants by ingrowth and mechanical interlocking. J. Biomed. Mater. Res. 6, 401–412 (1972)

    Google Scholar 

  • Schenk, R.: Zur histologischen Verarbeitung von unentkalkten Knochen. Acta Anat. 60, 3–19 (1965)

    Google Scholar 

  • Weinstein, A. L.: Persönl. Mitteilung (1977)

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Professor Dr. L. L. Hench sowie Dr. D. Greenspan, Gainesville/Florida, sind wir für die Überlassung der Implantate zu außerordentlichem Dank verpflichtet

Rights and permissions

Reprints and permissions

About this article

Cite this article

Griss, P., Werner, E., Heimke, G. et al. Vergleichende experimentelle Untersuchungen an Bioglas (L. L. Hench), Al2O3-Keramik und mit mod. Bioglas beschichteter Al2O3-Keramik. Arch orthop Unfall-Chir 90, 15–27 (1977). https://doi.org/10.1007/BF00415891

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00415891

Navigation