Skip to main content
Log in

Granulomatous pseudotumors in total joint replacement

  • Articles
  • Published:
Skeletal Radiology Aims and scope Submit manuscript

Abstract

Fourteen patients (15 joints) developed a foreign body reaction to methylmethacrylate, polyethylene, or metal adjacent to a total joint implan, a condition we would like to term granulomatous pseudotumors. There were eight male and six female patients. Their average age was 61 years. The hip was involved in 14 joints (femoral component 11 times, acetabulum 7, and great trochanter once). One patient presented with granulomatous pseudotumors of the knee. The principal findings included increasing pain and radiographic evidence of loosening occurring on average 2.7 years following the implant. This was followed by a characteristic and gradually developing radiographic pattern of discrete rounded lucencies. These developed into large ovoid lytic areas, destroying both methylmethacrylate and bone. Histologically, the appearances were characterized by histiocytic infiltration and the presence of multiple foreign body giant cells. Foreign material was identified in 9 of 11 cases. The pathogenesis is unknown but appears related to micromovement or loosening of the implant.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bell RS, Ha'eri GB, Goodman SB, Fornasier VL (1983) Case report 246. Skeletal Radiol 10:201

    Google Scholar 

  2. Bell RS, Schatzker J, Fornasier VL, Goodman SB (1985) A study of implant failure in the Wagner resurfacing arthroplasty. J Bone Joint Surg [Am] 67:1165

    Google Scholar 

  3. Brown IW, Ring PA (1985) Osteolytic changes in the upper femoral shaft following porous-coated hip replacement. J Bone Joint Surg [Br] 67:218

    Google Scholar 

  4. Bullough PG (1979) Pathologic changes associated with the common arthritides and their treatment. Pathol Annu 14:269

    Google Scholar 

  5. Crugnola A, Schiller A, Radin E (1977) Polymeric debris in synovium after total joint replacement: Histological identification. J Bone Joint Surg [Am] 59:860

    Google Scholar 

  6. Deutman R, Mulder, Brian R, Nater JP (1977) Metal sensitivity before and after total hip arthroplasty. J Bone Joint Surg [Am] 59:862

    Google Scholar 

  7. Fitzgerald RH Jr., Kelly PJ (1979). Total joint arthroplasty. Biologic causes of failure. Mayo Clin Proc 54:590

    Google Scholar 

  8. Freeman MAR, Bradley GW, Revell PA (1982) Observations upon the interface between bone and polymethylmethacrylate cement. J Bone Joint Surg [Br] 64:489

    Google Scholar 

  9. Goldring SR, Schiller AL, Roelke M, Rourke CM, O'Neill DA, Harris WH (1983) The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg [Am] 65:575

    Google Scholar 

  10. Harris WH, Schiller AL, Scholler J-M, Freiberg RA, Scott R (1976) Extensive localized bone resorption in the femur following total hip replacement. J Bone Joint Surg [Am] 58:612

    Google Scholar 

  11. Jasty MJ, Floyd WE III, Schiller AL, Goldring SR, Harris WH (1986) Localized osteolysis in stable, non-septic total hip replacement. J Bone Joint Surg [Am] 68:912

    Google Scholar 

  12. Kumar P, Bryan CE, Leech SH, Mathews R, Bowler J, D'Ambrosia RD (1983) Metal hypersensitivity in total joint replacement. Orthopedics 6:1455

    Google Scholar 

  13. Pazzaglia U, Byers PD (1984) Fractured femoral shaft through an osteolytic lesion resulting from the reaction to a prosthesis. J Bone Joint Surg [Br] 66:337

    Google Scholar 

  14. Rosenthal DI, Rosenberg AE, Schiller AL, Smith RJ (1983) Destructive arthritis due to silicone: A foreign-body reaction. Radiology 149:69

    Google Scholar 

  15. Scott WW Jr, Riley LH Jr, Dorfman HD (1985) Focal lytic lesions associated with femoral stem loosening in total hip prosthesis. AJR 144:977

    Google Scholar 

  16. Telaranta T, Solonen KA, Tallroth K, Nickels J (1983) Bone cysts containing silicone particles in bones adjacent to a carpal sialastic implant. Skeletal Radiol 10:247

    Google Scholar 

  17. Willert HG, Frech HA, Bechtel A (1975) Measurements of the quantity of monomer leaching out of acrylic bone cement into the surrounding tissues during the process of polymerization. In: Gregor HP (ed) Biomedical applications of polymers. Plenum, New York, p 121

    Google Scholar 

  18. Willert HG, Semlitsch M, Buchhorn G, Kriete U (1978) Wear of materials and tissue response in artificial joints. Orthopäde 7:62

    Google Scholar 

  19. Willert HG, Buchhorn G, Semlitsch M (1980) Tissue reaction to abrasion of upper extremity joint endoprostheses. Orthopädie 9:94

    Google Scholar 

  20. Willert HG, Buchhorn U, Zichner L (1980) Clinical experience with Mueller total hip endoprostheses of different design and material. Arch Orthop Trauma Surg 97:197

    Google Scholar 

  21. Leading Article (1980) Can metal sensitivity loosen joint replacements? Lancet, p 1284

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Griffiths, H.J., Burke, J. & Bonfiglio, T.A. Granulomatous pseudotumors in total joint replacement. Skeletal Radiol 16, 146–152 (1987). https://doi.org/10.1007/BF00367764

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00367764

Key words

Navigation