Skip to main content

Part of the book series: Documenta Ophthalmologica Proceedings Series ((DOPS,volume 19))

Abstract

115 eyes of 63 patients with neurological diseases were examined with an automatic computerized perimeter. Manual kinetic perimetry with Goldmann’s instrument was used for comparison. In 92 fields the automatic method disclosed all defects that had been found by manual perimetry. Furthermore, in 8 fields it revealed small defects that had been missed at the initial manual examination. The remaining 15 fields were normal using both methods. In 22 pathological fields of 12 patients both examinations were repeated during the course of the disease and showed parallel improvement, deterioration or unchanged defects. It was concluded that the automatic method is superior to manual kinetic perimetry in detecting visual field defects of neurological origin, and that it may replace the manual method in following up small and medium-sized defects. For large defects it is not suitable.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  • Bynke, H. , Heijl, A. Automatic computerized perimetry in the detection of neurological visual field defects. A pilot study. Graefes Arch. Ophthal. in press(1978).

    Google Scholar 

  • Heijl, A. Computer test logics for automatic perimetry. Acta Ophthal (Kbh.) 55:837–853 (1977).

    Article  PubMed  CAS  Google Scholar 

  • Heijl, A. , Krakau, C.E.T. An automatic perimeter for glaucoma visual field screening and control. Construction and clinical cases. Graefes Arch. Ophthal. 197: 13–23 (1975).

    CAS  Google Scholar 

  • Krakau, C.E.T. Aspects on the design of an automatic perimeter. Acta Ophthal (Kbh.), in press (1978).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

E. L. Greve

Rights and permissions

Reprints and permissions

Copyright information

© 1979 Dr W. Junk bv Publishers

About this chapter

Cite this chapter

Bynke, H., Heijl, A., Holmin, C. (1979). Automatic Computerized Perimetry in Neuro-Ophthalmology. In: Greve, E.L. (eds) Third International Visual Field Symposium Tokyo, May 3–6, 1978. Documenta Ophthalmologica Proceedings Series, vol 19. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-9611-3_35

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-9611-3_35

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-90-6193-160-7

  • Online ISBN: 978-94-009-9611-3

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics