Abstract
Physiological methods for measuring total lung capacity (TLC), including body-box plethysmography (BBP), are costly and require specialized expertise. Computed tomography (CT)-based TLC assessment is essential in clinical practice for candidates of lung transplantation and those unable to undergo standard lung function testing. While CT-based algorithms were studied to estimate TLC, their accuracy should be further evaluated. This study aimed to compare the BBP measurement of TLC (TLCpleth) with three CT-based methods for measuring TLC, one of them is an innovative virtual reality (VR)-based method. Additionally, we aimed to develop an adjustment factor that will allow a new, non-invasive, cost-effective estimation of the TLCpleth. TLC was calculated for 24 adult patients using three different CT-based volumetric assessment methods: an older region-growing algorithm (TLCrg), a more recent convolutional neural network-based algorithm (TLCcnn), and a VR-based method (TLCvr). Agreement between each method and TLCpleth was evaluated, and an adjustment factor was developed using linear regression. The correlation between the three CT-based methods and TLCpleth ranged from 0.91 to 0.92 (p < 0.001). TLCvr measurements were 80.13% (CI:75.08–85.18%, P < 0.001) of TLCpleth measures, whereas TLCcnn and TLCrg estimates were 71.3% and 77.1% of TLCpleth, respectively. An adjustment factor is proposed to estimate TLCpleth based on the three CT-based methods. This study is the first to evaluate the correlation between BBP, VR volumetric analysis, and two iterations of CT volumetric software for measuring total lung capacity (TLC). After being corrected by an adjustment factor, VR- and CT-based assessments provide accurate estimates of TLCpleth.
Similar content being viewed by others
Data availability
The data used to support the findings of this study are available from the corresponding author upon request.
Abbreviations
- TLCrg:
-
Total lung capacity (TLC) calculated by a region-growing algorithm
- TLCcnn:
-
TLC calculated by a convolutional neural network (CNN)-based algorithm
- TLCvr:
-
TLC calculated by a virtual reality (VR)-based algorithm
- TLCpleth:
-
TLC calculated by body-box plethysmography
References
Altman DG, Bland JM (1983) Measurement in medicine: the analysis of method comparison studies. Statistician 32(3):307. https://doi.org/10.2307/2987937
Alves AFF, Miranda JRA, Reis F, Oliveira AA, Souza SAS, Fortaleza CMCB, Tanni SE, Castro JTS, Pina DR (2021) Automatic algorithm for quantifying lung involvement in patients with chronic obstructive pulmonary disease, infection with SARS-CoV-2, paracoccidioidomycosis and no lung disease patients. PLOS ONE 16(6):e0251783. https://doi.org/10.1371/journal.pone.0251783
Bakker JT, Klooster K, Bouwman J, Pelgrim GJ, Vliegenthart R, Slebos D-J (2022) Evaluation of spirometry-gated computed tomography to measure lung volumes in emphysema patients. ERJ Open Res 8(1):00492–02021. https://doi.org/10.1183/23120541.00492-2021
Brown R, Ingram RH, McFadden ER (1978) Problems in the plethysmographic assessment of changes in total lung capacity in asthma 1–3. Am Rev Respir Dis 118(4):685–692. https://doi.org/10.1164/arrd.1978.118.4.685
Brown MS, Kim HJ, Abtin F, Da Costa I, Pais R, Ahmad S, Angel E et al (2010) Reproducibility of lung and lobar volume measurements using computed tomography. Acad Radiol 17(3):316–322. https://doi.org/10.1016/j.acra.2009.10.005
Camargo JJP, Irion KL, Marchiori E, Hochhegger B, Porto NS, Moraes BG, Meyer G, Caramori M, Holemans JA (2009) Computed tomography measurement of lung volume in preoperative assessment for living donor lung transplantation: volume calculation using 3D surface rendering in the determination of size compatibility. Pediatr Transplant 13(4):429–439. https://doi.org/10.1111/j.1399-3046.2008.01016.x
Cardenas CE, Yang J, Anderson BM, Court LE, Brock KB (2019) Advances in auto-segmentation. Semin Radiat Oncol 29(3):185–197. https://doi.org/10.1016/j.semradonc.2019.02.001
Caruso P, Pereira AL, de Albuquerque P, Santana V, Cardenas LZ, Ferreira JG, Prina E, Trevizan PF et al (2015) Diagnostic methods to assess inspiratory and expiratory muscle strength. J Bras Pneumol 41(2):110–123. https://doi.org/10.1590/S1806-37132015000004474
Choi JY, Rhee CK (2020) Diagnosis and treatment of early chronic obstructive lung disease (COPD). J Clin Med 9(11):3426. https://doi.org/10.3390/jcm9113426
Cliff IJ, Evans AH, Pantin CF, Baldwin DR (1999) Comparison of two new methods for the measurement of lung volumes with two standard methods. Thorax 54(4):329–333. https://doi.org/10.1136/thx.54.4.329
Ciobota ND (2012) Standard tessellation language in rapid prototyping technology. Sci Bull Valahia Univ 7:81–5
Cooper BG (2011) An update on contraindications for lung function testing. Thorax 66(8):714–723. https://doi.org/10.1136/thx.2010.139881
Coxson HO (2013) Sources of variation in quantitative computed tomography of the lung. J Thorac Imaging 28(5):272–279. https://doi.org/10.1097/RTI.0b013e31829efbe9
Coxson HO, Leipsic J, Parraga G, Sin DD (2014) Using pulmonary imaging to move chronic obstructive pulmonary disease beyond FEV1. Am J Respir Crit Care Med 190(2):135–144. https://doi.org/10.1164/rccm.201402-0256PP
Criée CP, Sorichter S, Smith HJ, Kardos P, Merget R, Heise D, Berdel D et al (2011) Body plethysmography—its principles and clinical use. Respir Med 105(7):959–971. https://doi.org/10.1016/j.rmed.2011.02.006
D’Ascanio M, Viccaro F, Calabrò N, Guerrieri G, Salvucci C, Pizzirusso D, Mancini R, De Vitis C, Pezzuto A, Ricci A (2020) Assessing static lung hyperinflation by whole-body plethysmography, helium dilution, and impulse oscillometry system (IOS) in patients with COPD. Int J Chron Obstruct Pulmon Dis 15:2583–2589. https://doi.org/10.2147/COPD.S264261
Dettmer S, Suhling H, Klingenberg I, Otten O, Kaireit T, Fuge J, Kuhnigk JM et al (2018) Lobe-wise assessment of lung volume and density distribution in lung transplant patients and value for early detection of bronchiolitis obliterans syndrome. Eur J Radiol 106:137–144. https://doi.org/10.1016/j.ejrad.2018.07.016
Eberlein M, Reed RM, Maidaa M, Bolukbas S, Arnaoutakis GJ, Orens JB, Brower RG, Merlo CA, Hunsicker LG (2013) Donor–recipient size matching and survival after lung transplantation. A cohort study. Ann Am Thorac Soc 10(5):418–425. https://doi.org/10.1513/AnnalsATS.201301-008OC
Fred HL (2004) Drawbacks and limitations of computed tomography. Tex Heart Inst J 31(4):345
Freidin D, Singolda R, Tejman-Yarden S, Parmat Y, Liran A, Ofir H, Saukhat O, Haik J, Barnea Y, Tessone A (2023) Using virtual reality for deep inferior epigastric perforator flap preoperative planning. Plast Reconstr Surg-Glob Open 11(1):e4773. https://doi.org/10.1097/GOX.0000000000004773
Garfield JL, Marchetti N, Gaughan JP, Steiner RM, Criner GJ (2012) Total lung capacity by plethysmography and high-resolution computed tomography in COPD. Int J Chronic Obstr Pulm Dis. https://doi.org/10.2147/COPD.S26419
Grippi MA, Tino G (2015) Chapter 33: pulmonary function testing
Haas M, Hamm B, Niehues SM (2014) Automated lung volumetry from routine thoracic CT scans. Acad Radiol 21(5):633–638. https://doi.org/10.1016/j.acra.2014.01.002
Herrmann P, Busana M, Cressoni M, Lotz J, Moerer O, Saager L, Meissner K, Quintel M, Gattinoni L (2021a) Using artificial intelligence for automatic segmentation of CT lung images in acute respiratory distress syndrome. Front Physiol 12:1–16. https://doi.org/10.3389/fphys.2021.676118
Herrmann P, Busana M, Cressoni M, Lotz J, Moerer O, Saager L, Meissner K, Quintel M, Gattinoni L (2021b) Using artificial intelligence for automatic segmentation of CT lung images in acute respiratory distress syndrome. Front Physiol 12:676118. https://doi.org/10.3389/fphys.2021.676118
Hofmanninger J, Prayer F, Pan J, Röhrich S, Prosch H, Langs G (2020) Automatic lung segmentation in routine imaging is primarily a data diversity problem, not a methodology problem. Eur Radiol Exp 4(1):50. https://doi.org/10.1186/s41747-020-00173-2
Hoogendijk EO, Afilalo J, Ensrud KE, Kowal P, Onder G, Fried LP (2019) Frailty: implications for clinical practice and public health. The Lancet 394(10206):1365–1375. https://doi.org/10.1016/S0140-6736(19)31786-6
Hunger T, Wanka-Pail E, Brix G, Griebel J (2021) Lung cancer screening with low-dose CT in smokers: a systematic review and meta-analysis. Diagnostics 11(6):1040. https://doi.org/10.3390/diagnostics11061040
Iwano S, Okada T, Satake H, Naganawa S (2009) 3D-CT volumetry of the lung using multidetector row CT. Acad Radiol 16(3):250–256. https://doi.org/10.1016/j.acra.2008.09.019
Kakavas S, Kotsiou OS, Perlikos F, Mermiri M, Mavrovounis G, Gourgoulianis K, Pantazopoulos I (2021) Pulmonary function testing in COPD: looking beyond the curtain of FEV1. Npj Prim Care Respir Medi 31(1):23. https://doi.org/10.1038/s41533-021-00236-w
Kang HS, Shin AY, Yeo CD, Kim JS, Kim YH, Kim JW, Lee SH (2018) A lower level of forced expiratory volume in one second predicts the poor prognosis of small cell lung cancer. J Thorac Dis 10(4):2179–2185. https://doi.org/10.21037/jtd.2018.03.121
Kauczor HU, Heussel CP, Fischer B, Klamm R, Mildenberger P, Thelen M (1998) Assessment of lung volumes using helical CT at inspiration and expiration: comparison with pulmonary function tests. Am J Roentgenol 171(4):1091–1095. https://doi.org/10.2214/ajr.171.4.9763003
Kim YJ, Lee SH, Park CM, Kim KG (2016) Evaluation of semi-automatic segmentation methods for persistent ground glass nodules on thin-section CT scans. Healthcare Inform Res 22(4):305. https://doi.org/10.4258/hir.2016.22.4.305
Kim Y, Kim SH, Rhee CK, Lee JS, Lee CY, Kim DK, Shin K-C, Jung KS, Yoo KH, Park YB (2022) Air trapping and the risk of COPD exacerbation: analysis from prospective KOCOSS cohort. Front Med 9:835069. https://doi.org/10.3389/fmed.2022.835069
Konheim JA, Kon ZN, Pasrija C, Luo Q, Sanchez PG, Garcia JP, Griffith BP, Jeudy J (2016) Predictive equations for lung volumes from computed tomography for size matching in pulmonary transplantation. J Thorac Cardiovasc Surg 151(4):1163-1169.e1. https://doi.org/10.1016/j.jtcvs.2015.10.051
Lawson G, Salanitri D, Waterfield B (2016) Future directions for the development of virtual reality within an automotive manufacturer. Appl Ergon 53:323–330. https://doi.org/10.1016/j.apergo.2015.06.024
Li H, Zeng W, Morvan JM, Chen L, Xianfeng David Gu (2014) Surface meshing with curvature convergence. IEEE Trans Visual Comput Graphics 20(6):919–934. https://doi.org/10.1109/TVCG.2013.253
Lin L (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45(1):255. https://doi.org/10.2307/2532051
López J, Esteban A, Hernández J, Gómez P, Zamora R, Zanzi C, Faura F (2021) A new iso-surface extraction method on arbitrary grids. J Comput Phys 444:110579. https://doi.org/10.1016/j.jcp.2021.110579
Luo J, Liu D, Chen G, Liang B, Liu C (2017) Clinical roles of lung volumes detected by body plethysmography and helium dilution in asthmatic patients: a correlation and diagnosis analysis. Sci Rep 7(1):40870. https://doi.org/10.1038/srep40870
Madan R, Chansakul T, Goldberg HJ (2014) Imaging in lung transplants: checklist for the radiologist. Indian J Radiol Imaging 24(04):318–326. https://doi.org/10.4103/0971-3026.143894
Makarov SN, Noetscher GM, Nummenmaa A (eds) (2021) Brain and human body modeling 2020: Computational human models presented at EMBC 2019 and the BRAIN initiative® 2019 meeting. Springer International Publishing, Cham. https://doi.org/10.1007/978-3-030-45623-8
Mangukia C, Shigemura N, Stacey B, Sunagawa G, Muhammad N, Espinosa J, Kehara H et al (2021) Donor quality assessment and size match in lung transplantation. Indian J Thorac Cardiovasc Surg 37(S3):401–415. https://doi.org/10.1007/s12055-021-01251-9
Mascalchi M, Camiciottoli G, Diciotti S (2017) Lung densitometry: why, how and when. J Thorac Dis 9(9):3319–3345. https://doi.org/10.21037/jtd.2017.08.17
Matsumoto AJ, Bartholmai BJ, Wylam ME (2017) Comparison of total lung capacity determined by plethysmography with computed tomographic segmentation using CALIPER. J Thorac Imaging 32(2):101–106. https://doi.org/10.1097/RTI.0000000000000249
Mele B, Altarelli G (1993) Lepton spectra as a measure of b quark polarization at LEP. Phys Lett B 299(3–4):345–350. https://doi.org/10.1016/0370-2693(93)90272-J
Mesanovic N, Grgic M, Huseinagic H, Males M, Skejic E, Smajlovic M (2020) Automatic CT image segmentation of the lungs with region growing algorithm
Nguyen BJ, Khurana A, Bagley B, Yen A, Brown RK, Stojanovska J, Cline M, Goodsitt M, Obrzut S (2018) Evaluation of virtual reality for detection of lung nodules on computed tomography. Tomography 4(4):204–208. https://doi.org/10.18383/j.tom.2018.00053
O’Donnell CR, Bankier AA, Stiebellehner L, Reilly JJ, Brown R, Loring SH (2010) Comparison of plethysmographic and helium dilution lung volumes. Chest 137(5):1108–1115. https://doi.org/10.1378/chest.09-1504
Ou H, Jialiang Su, Lan S, Wang L, Xiangyang Xu, Johnson S (2019) Development of a simplified, reproducible, parametric 3D model of the talus. Med Eng Phys 71:3–9. https://doi.org/10.1016/j.medengphy.2019.06.022
Park CH, Kim TH, Lee S, Paik HC, Haam SJ (2015) New Predictive equation for lung volume using chest computed tomography for size matching in lung transplantation. Transpl Proc 47(2):498–503. https://doi.org/10.1016/j.transproceed.2014.12.025
Patel N, DeCamp M, Criner GJ (2008) Lung transplantation and lung volume reduction surgery versus transplantation in chronic obstructive pulmonary disease. Proc Am Thorac Soc 5(4):447–453. https://doi.org/10.1513/pats.200707-107ET
Pearson K (1913) On the probable error of a coefficient of correlation an found from a fourfold tabtle. Biometrika. https://doi.org/10.1093/biomet/9.1-2.22
Peng T-F, Ren T, Wang H-S, Feng Z-X, Wang M-F (2020) Diagnostic value of rapid on-site evaluation for CT-guided percutaneous fine needle aspiration in the diagnosis of pulmonary occupying lesions. BioMed Res Int. https://doi.org/10.1155/2020/9842768
Pires F, Costa C, Dias P (2021) On the use of virtual reality for medical imaging visualization. J Digit Imaging 34(4):1034–1048. https://doi.org/10.1007/s10278-021-00480-z
Quanjer PH, Europäische Gemeinschaft für Kohle und Stahl, European Respiratory Society, and European Respiratory Society (1993) Standardized lung function testing: report; official statement of the european respiratory society. Eur Respir J Suppl 16:1–100
Rahman MM, Siddiqui MMR (2017) Global initiative for chronic obstructive lung disease (GOLD). Anwer Khan Mod Med Coll J 7(1):4. https://doi.org/10.3329/akmmcj.v7i1.31596
Reiterer F, Sivieri E, Abbasi S (2015) Evaluation of bedside pulmonary function in the neonate: from the past to the future: bedside pulmonary function testing in the neonate. Pediatr Pulmonol 50(10):1039–1050. https://doi.org/10.1002/ppul.23245
Revol-Muller C, Peyrin F, Carrillon Y, Odet C (2002) Automated 3D region growing algorithm based on an assessment function. Pattern Recogn Lett 23(1–3):137–150. https://doi.org/10.1016/S0167-8655(01)00116-7
Rodenstein DO, Stănescu DC, Francis C (1982) Demonstration of failure of body plethysmography in airway obstruction. J Appl Physiol Respir Environ Exerc Physiol 52(4):949–954. https://doi.org/10.1152/jappl.1982.52.4.949
Sadeghi AH, Maat APWM, Taverne YJHJ, Cornelissen R, Dingemans A-M, Bogers AdJJC, Mahtab EAF (2021) Virtual reality and artificial intelligence for 3-dimensional planning of lung segmentectomies. JTCVS Techniques 7:309–321. https://doi.org/10.1016/j.xjtc.2021.03.016
Salisbury ML, Xia M, Zhou Y, Murray S, Tayob N, Brown KK, Wells AU, Schmidt SL, Martinez FJ, Flaherty KR (2016) Idiopathic pulmonary fibrosis. Chest 149(2):491–498. https://doi.org/10.1378/chest.15-0530
Seguin-Givelet A, Grigoroiu M, Brian E, Gossot D (2018) Planning and marking for thoracoscopic anatomical segmentectomies. J Thorac Dis 10(Suppl 10):S1187. https://doi.org/10.21037/jtd.2018.02.21
Si-Mohamed SA, Nasser M, Colevray M, Nempont O, Lartaud P-J, Vlachomitrou A, Broussaud T et al (2022) Automatic quantitative computed tomography measurement of longitudinal lung volume loss in interstitial lung diseases. Eur Radiol 32(6):4292–4303. https://doi.org/10.1007/s00330-021-08482-9
Stanescu DC, Rodenstein D, Cauberghs M, Van de Woestijne KP (1982) Failure of body plethysmography in bronchial asthma. J Appl Physiol 52(4):939–948. https://doi.org/10.1152/jappl.1982.52.4.939
Sverzellati N, Calabrò E, Chetta A, Concari G, Larici AR, Mereu M, Cobelli R, De Filippo M, Zompatori M (2007) Visual score and quantitative CT indices in pulmonary fibrosis: relationship with physiologic impairment. Radiol Med (torino) 112(8):1160–1172. https://doi.org/10.1007/s11547-007-0213-x
Swanney MP, Ruppel G, Enright PL, Pedersen OF, Crapo RO, Miller MR, Jensen RL et al (2008) Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction. Thorax 63(12):1046–1051. https://doi.org/10.1136/thx.2008.098483
Tang Y, Zhang M, Feng Y, Liang B (2016) The Measurement of lung volumes using body plethysmography and helium dilution methods in COPD patients: a correlation and diagnosis analysis. Sci Rep 6(1):37550. https://doi.org/10.1038/srep37550
Tejman-Yarden S, Freidin D, Nagar N, Parmet Y, Abed M, Vazhgovsky O, Yogev D et al (2023) Virtual reality utilization for left atrial appendage occluder device size prediction. Heliyon 9(4):e14790. https://doi.org/10.1016/j.heliyon.2023.e14790
Trussell HJ (1979) Comments on picture thresholding using an iterative selection method. IEEE Trans Syst, Man, Cybern 9(5):311–311
Tsutsumi Y, Fukuma S, Tsuchiya A, Ikenoue T, Yamamoto Y, Shimizu S, Kimachi M, Fukuhara S (2017) Computed tomography during initial management and mortality among hemodynamically unstable blunt trauma patients: a nationwide retrospective cohort study. Scand J Trauma, Resusc Emerg Med 25(1):74. https://doi.org/10.1186/s13049-017-0396-7
Vermeiren S, Vella-Azzopardi R, Beckwée D, Habbig A-K, Scafoglieri A, Jansen B, Bautmans I et al (2016) Frailty and the prediction of negative health outcomes: a meta-analysis. J Am Med Dir Assoc 17(12):1163.e1-1163.e17. https://doi.org/10.1016/j.jamda.2016.09.010
Weng W, Zhu X (2021) INet: convolutional networks for biomedical image segmentation. IEEE Access 9:16591–16603. https://doi.org/10.1109/ACCESS.2021.3053408
Yogev D, Tejman-Yarden S, Feinberg O, Parmet Y, Goldberg T, Illouz S, Nagar N et al (2022) Proof of concept: comparative accuracy of semiautomated VR modeling for volumetric analysis of the heart ventricles. Heliyon 8(11):e11250. https://doi.org/10.1016/j.heliyon.2022.e11250
Zapke M, Topf HG, Zenker M, Kuth R, Deimling M, Kreisler P, Rauh M, Chefd’hotel C, Geiger B, Rupprecht T (2006) Magnetic resonance lung function–a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial. Respir Res 7(1):1–9. https://doi.org/10.1186/1465-9921-7-106
Zhang C, Chen T (2001) Efficient Feature Extraction for 2D/3D objects in mesh representation. In Proceedings 2001 international conference on image processing (Cat. No.01CH37205). Thessaloniki, Greece: IEEE. vol 2, p 935–38. https://doi.org/10.1109/ICIP.2001.958278
Zhou J, Chao Y, Yao D, Ding N, Li J, Gao L, Zhang Y, Xu X, Zhou J, Halmos B, Tsoukalas N (2021) Impact of chronic obstructive pulmonary disease on immune checkpoint inhibitor efficacy in advanced lung cancer and the potential prognostic factors. Transl Lung Cancer Res 10(5):2148. https://doi.org/10.21037/tlcr-21-214
Acknowledgements
The authors wish to thank Esther Singer for her editorial assistance.
Funding
No funding.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
No other potential conflicts of interest relevant to this article were reported.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Yogev, D., Chatarji, S., Carl, L. et al. A comparative study of CT-based volumetric assessment methods for total lung capacity with the development of an adjustment factor: incorporating VR imaging for improved accuracy. Virtual Reality 28, 2 (2024). https://doi.org/10.1007/s10055-023-00892-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10055-023-00892-y