Abstract
In routine measurements, the length of analysis time and the number of samples analysed during a given time unit are crucial. Additionally, the analytical method used has to provide reliable results and be able to identify and quantify any compound present in the matrix. High-resolution equipment, including Orbitrap analysers, is commonly used for non-targeted determinations. However, researchers still rely on trial and error to achieve the best acquisition conditions on the mass spectrometer, which is a tedious and time-consuming process that can lead to errors. Moreover, tentative compound identification, particularly when using a non-targeted approach, heavily depends on commercial databases. All of these issues can ultimately result in incomplete identification of compounds in the study matrix. In this framework, the study presented here has a dual objective: to use the experimental design tool to optimise critical parameters in mass spectrometry using LC-Q-Orbitrap-MS equipment when working in a non-targeted approach and to compare the mzCloud™ and ChemSpider™ commercial databases included in Compound Discoverer software with TraceFinder home-made databases generated to evaluate the ability to identify compounds. The study’s noteworthy findings reveal that employing an experimental design has facilitated rapid optimisation of the mass spectrometer’s multiplexing and loop parameters. Furthermore, the study highlights that the lack of harmonisation in commercial databases poses a disadvantage in the identification of compounds, leading to superior results when using home-made databases. In the latter databases, around 80% of the compounds were identified, which is approximately twice the number identified in commercial databases (around 40% in the best case with ChemSpider™).
Graphical Abstract
Similar content being viewed by others
References
Marín-Sáez J, López-Ruíz R, Romero-González R, Garrido-Frenich A. Multiresidue methods for determination of pesticides and related contaminants in food by liquid chromatography in S. Fanali, B. Chankvetadze, P.R. Haddad, C.F. Poole, M.L. Riekkola, editors. Liquid Chromatography Applications. Amsterdam, Netherlands; Elsevier; 2023. pp. 705–732. https://doi.org/10.1016/B978-0-323-99969-4.00001-2.
Rajski L, Gómez Ramos MM, Fernández Alba AR. Evaluation of MS2 workflows in LC-Q-Orbitrap for pesticide multi-residue methods in fruits and vegetables. Anal Bioanal Chem. 2017;409:5389–400. https://doi.org/10.1007/s00216-017-0220-2.
Kaufman A. Analytical performance of the various acquisition modes in Orbitrap MS and MS/MS. J Mass Spectrom. 2018;53:725–38. https://doi.org/10.1002/jms.4195.
Carlsson H, Vaivade A, Khoosari PE, Burman J, Kultima KJ. Evaluation of polarity switching for untargeted lipidomics using liquid chromatography coupled to high resolution mass spectrometry. Chromatogr B. 2022;1195:123200. https://doi.org/10.1016/j.jchromb.2022.123200.
Kataoka H, Oshima H, Ohkawa T. Simultaneous analysis of multiple steroidal biomarkers in saliva for objective stress assessment by on-line coupling of automated in-tube solid-phase microextraction and polarity-switching LC-MS/MS. Talanta Open. 2023;7:100177. https://doi.org/10.1016/j.talo.2022.100177.
Rakk D, Kukolya J, Skbic BD, Vágvölgyi C, Varga M, Szekeres A. Advantages of multiplexing ability of the Orbitrap mass analyzer in the multi-mycotoxin analysis. Toxins. 2023;15:134. https://doi.org/10.3390/toxins15020134.
Kauffmann A, Bromirski M. Selecting the best Q exactive Orbitrap mass spectrometer scan mode for your application, technical note from Thermo ScientificTM . https://assets.thermofisher.com/TFS-Assets/CMD/Reference-Materials/wp-65147-ms-q-exactive-orbitrap-scan-modes-wp65147-en.pdf.
Egertson JD, Kuehn A, Merrihew GE, Bateman NW, MacLean BX, Ting YS, Canterbury JD, Marsh DM, Kellmann M, Zabrouskov V, Wu CC, MacCoss MJ. Multiplexed MSMS/MSMS for improved data-independent acquisition. Nat Methods. 2013;10:744–8. https://doi.org/10.1038/nmeth.2528.
Benedetti B, Caponigro V, Ardini F. Experimental design step by step: a practical guide for beginners. Crit Rev Anal Chem. 2022;52:1015–28. https://doi.org/10.1080/10408347.2020.1848517.
Ebrahimi NH. Experimental design in analytical chemistry—part I: theory. J AOAC Int. 2014;97:1. https://doi.org/10.5740/jaoacint.SGEEbrahimi1.
Jacyna J, Kordalewska M, Markiszewski MJ. Design of experiments in metabolomics-related studies: an overview. J Pharm Biomed Anal. 2019;164:598–606. https://doi.org/10.1016/j.jpba.2018.11.027.
Zhou Y, Song JZ, Choi FFK, Wu HF, Qiao CF, Ding LS, Gesang SL, Xu HX. An experimental design approach using response surface techniques to obtain optimal liquid chromatography and mass spectrometry conditions to determine the alkaloids in Meconopsi species. J Chromatogr A. 2009;1216:7013–23. https://doi.org/10.1016/j.chroma.2009.08.058.
Rhoades SD, Weijie AM. Comprehensive optimization of LC–MS metabolomics methods using design of experiments (COLMeD). Metabolomics. 2016;12:183. https://doi.org/10.1007/s11306-016-1132-4.
Rocha AL, Lourenço FR. Development and optimization of a LC-MS/MS compatible method for quantification of losartan, hydrochlorothiazide and their impurities using AQbD approach and measurement uncertainty evaluation. Talanta. 2023;259:124481. https://doi.org/10.1016/j.talanta.2023.124481.
Zhou H, Zhang M, Chen Q, Shan Q, Liu S, Lin J, Ma L, Zheng G, Li L, Zhao C, Wei L, Dai X, Yin Y. Determination of amphenicol antibiotic residues in aquaculture products by response surface methodology modified QuEChERS method combined with UPLC-MS/MS. Microchem J. 2023;190:108729. https://doi.org/10.1016/j.microc.2023.108729.
Roca M, Leon N, Pastor A, Yusà V. Comprehensive analytical strategy for biomonitoring of pesticides in urine by liquid chromatography–Orbitrap high resolution mass spectrometry. J Chroma A. 2014;29:66–76. https://doi.org/10.1016/j.chroma.2014.11.010.
Bheemanapally K, Ibrahim MMH, Briski KP. HPLC–electrospray ionization–mass spectrometry optimization by high-performance design of experiments for astrocyte glutamine measurement. J Mass Spectrom. 2021;56:e4680. https://doi.org/10.1002/jms.4680.
Riter LS, Vitek O, Gooding KM, Hodge BD, Julian RK. Statistical design of experiments as a tool in mass spectrometry. J Mass Spectrom. 2005;40:565–79. https://doi.org/10.1002/jms.871.
TraceFinder Software, Thermo Fisher Scientific. https://www.thermofisher.com/es/es/home/industrial/mass-spectrometry/liquid-chromatography-mass-spectrometry-lc-ms/lc-ms-software/lc-ms-data-acquisition-software/tracefinder-software.html. (Accessed 25 July 2023).
López-Ruiz R, Romero-González R, Garrido Frenich A. Simultaneous determination of polar pesticides in human blood serum by liquid chromatography coupled to triple quadrupole mass spectrometer. J Pharm Biomed Anal. 2020;190:113492. https://doi.org/10.1016/j.jpba.2020.113492.
Funding
AMJC acknowledges the Grant (RYC2021-031993-I) funded by MCIN/AEI/501100011033 and “European Union NextGeneration EU/PRTR”. RLR acknowledges to the Andalusia Ministry of Economic Transformation, Industry, Knowledge and Universities for financial support from “Ayudas para Captación, Incorporación y Movilidad de Capital Humano de I + D + i (PAIDI 2020)”.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Jimenez-Carvelo, A.M., López-Ruiz, R., Romero-González, R. et al. Critical evaluation of MS acquisition conditions and identification process in LC-Q-Orbitrap-MS for non-targeted analysis: pesticide residues as case of study. Anal Bioanal Chem 415, 6269–6277 (2023). https://doi.org/10.1007/s00216-023-04903-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-023-04903-4