Mycotoxins such as ochratoxin A, aflatoxin B and others are dangerous food contaminants that usually occur in trace amounts from nanograms to micrograms per gram of food. Therefore high sensitive methods are necessary for their detection. The conventional methods such are high-performance liquid chromatography (HPLC), mass spectroscopy are rather expensive and time consuming, therefore biosensor technology is rather promising for rapid detection of toxicants in field conditions, far from specialized laboratories. Among biosensors based on affinity of monoclonal antibodies or DNA aptamers to mycotoxins are of special interest, because provide sensitivity of detection that is better than allowable quantities of toxicants in food. While antibodies are traditional receptors in biosensors, aptamers are novel biopolymers with the affinity comparable to that of antibodies. However in contrast with antibodies, aptamers are more stable and the biosensors based on DNA aptamers can be regenerated which allowing their multiple use. This contribution reviews recent achievements in development affinity biosensors for detection ochratoxin A.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Paddle BM (1996) Biosensors for chemical and biological agents of defence interest. Biosens Bioelectron 11:1079

    Article  CAS  Google Scholar 

  2. Ringot D, Chango A, Schneider Y-J, Larondelle Y (2006) Toxicokinetics and toxicodynamics of ochratoxin A, an update. Chem Biol Interact 159:18

    Article  CAS  Google Scholar 

  3. El Khoury A, Atoui A (2010) Ochratoxin A: General overview and actual molecular status. Toxins 2:461

    Article  CAS  Google Scholar 

  4. Gautier J-C, Holzhaeuser D, Markovic J, Gremaud E, Schilter B, Turesky RJ (2001) Oxidative damage and stress response from ochratoxin A exposure in rats. Free Rad Biol Med 30:1089

    Article  CAS  Google Scholar 

  5. Schaaf GJ, Nijmeijer SM, Maas RFM, Roestenberg P, de Groene EM, Fink-Gremmels J (2002) The role of oxidative stress in the ochratoxin A-mediated toxicity in proximal tubular cells. Biochim Biophys Acta 1588:149

    CAS  Google Scholar 

  6. Creppy EE, Kane A, Dirheimer G, Lafarge-Frayssinet C, Mousset S, Frayssinet C (1985) Genotoxicity of ochratoxin A in mice: DNA single strand break evaluation in spleen, liver and kidney. Toxicol Lett 28:29

    Article  CAS  Google Scholar 

  7. Lebrun S, Follmann W (2002) Detection of ochratoxin A–induced DNA damage in MDCK cells by alkaline single cell electrophoresis (comet assay). Arch Toxicol 75:734

    Article  CAS  Google Scholar 

  8. Oliveira SCB, Diculescu VC, Palleschi G, Compagnone D, Oliveira-Brett AM (2007) Electrochemical oxidation of ochratoxin A at a glassy carbon electrode and in situ evaluation of the interaction with deoxyribonucleic acid using an electrochemical deoxyribonucleic acid-biosensor. Anal Chim Acta 588:283

    Article  CAS  Google Scholar 

  9. Mally A, Zepnik H, Waken P, Eder E, Dingley K, Ihmels H, Volkel W, Dekat W (2004) Ochratoxin A: lack of formation of covalent DNA adducts. Chem Res Toxicol 17:234

    Article  CAS  Google Scholar 

  10. Gillman IG, Clark TN, Manderville RA (1999) Oxidation of ochratoxin A by an Fe-porphyrin system: model for enzymatic activation and DNA cleavage. Chem Res Toxicol 12:1066

    Article  CAS  Google Scholar 

  11. Pittet A (1998) Natural occurrence of mycotoxins in foods and feeds: an updated review. Rev Med Vet 149:479

    CAS  Google Scholar 

  12. Uchiyama S, Saito Y (1987) Protein-binding potential of ochratoxin A in vitro and Its fluorescence enhancement. J Food Hyg Soc Jpn 28:453

    Article  CAS  Google Scholar 

  13. Whitley RD, Wachter R, Liu F, Wang NH (1989) Ion exchange equilibria of lysozyme, myoglobin and bovine serum albumin. J Chromatogr 465:137

    Article  CAS  Google Scholar 

  14. Zimmerli B, Dick R (1995) Determination of ochratoxin A at the ppt level in human blood, serum, milk and some foodstuffs by high-performance liquid chromatography with enhanced fluorescence detection and immunoaffinity column cleanup methodology and Swiss data. J Chromatogr B 666:85

    Article  CAS  Google Scholar 

  15. Olsson J, Borjesson T, Lundstedt T, Schnurer J (2002) Detection and quantification of ochratoxin A and deoxynivalenol in barley grains by GC–MS and electronic nose. Int J Food Microbiol 72:203

    Article  CAS  Google Scholar 

  16. Penas EG, Leache C, de Cerain AL, Lizarraga E (2006) Comparison between capillary electrophoresis and HPLC-FL forochratoxin A quantification in wine. Food Chem 97:349

    Article  Google Scholar 

  17. Obrecht-Pflumio S, Dirheimer G (2000) In vitro DNA and dGMP addcuts formation caused by ochratoxin A. Chem Biol Interact 127:29

    Article  CAS  Google Scholar 

  18. Aizawa M (1987) Immunosensors. Philos Trans R Soc Lond B316:121

    Google Scholar 

  19. Scott PM (2002) Methods of analysis for ochratoxin A. Mycotoxins Food Safe 504:117

    Article  CAS  Google Scholar 

  20. Nikolelis DP, Petropoulou S-SE, Mitrokotsa MV (2002) A minisensor for the rapid screening of atenolol in pharmaceutical preparations based on surface-stabilized bilayer lipid membranes with incorporated DNA. Bioelectrochemistry 58:107

    Article  CAS  Google Scholar 

  21. Mohsin MA, Banica F-G, Oshima T, Hianik T (2011) Electrochemical impedance spectroscopy for assessing the recognition of cytochrome c by immobilized calixarenes. Electroanalysis 23:1229

    Article  CAS  Google Scholar 

  22. Hall EAH (1991) Biosensors. Prentice-Hall, Englewood Press, Englewood Cliffs

    Google Scholar 

  23. Eggins BR (2002) Chemical sensors and biosensors. Wiley, Chichester

    Google Scholar 

  24. Wang J (2006) Analytical electrochemistry. Wiley, Hoboken

    Book  Google Scholar 

  25. Calcutt MW, Gillman IG, Noftle RE, Manderville RA (2001) Electrochemical oxidation of ochratoxin A. Correlation with 4-chlorophenol. Chem Res Toxicol 14:1266

    Article  CAS  Google Scholar 

  26. Manderville RA, Calcutt MW, Dai J, Park G, Gillman IG, Noftle RE, Mohammed AK, Dizdaroglu M, Rodriguez H, Akman SA (2003) Stoichiometric preference in copper-promoted oxidative DNA damage by ochratoxin A. J Inorg Biochem 95:87

    Article  CAS  Google Scholar 

  27. Alonso-Lomillo MA, Domínguez-Renedo O, Ferreira-Goncalves L, Arcos-Martínez MJ (2010) Sensitive enzyme-biosensor based on screen-printed electrodes for Ochratoxin A. Biosens Bioelectron 25:1333

    Article  CAS  Google Scholar 

  28. Alonso-Lomillo MA, Domínguez-Renedo O, del Torno-de Roman L, Arcos-Martínez MJ (2011) Horseradish peroxidase-screen printed biosensors for determination of Ochratoxin A. Anal Chim Acta 688:49

    Article  CAS  Google Scholar 

  29. Perrotta PR, Vettorazzi NR, Arevalo FJ, Granero AM, Chulze SN, Zon MA, Fernandez H (2011) Electrochemical studies of ochratoxin A mycotoxin at gold electrodes modified with cysteamine self-assembled monolayers. Its ultrasensitive quantification in red wine samples. Electroanalysis 23:1585

    Article  CAS  Google Scholar 

  30. Alarcon SH, Palleschi G, Compagnone D, Pascale M, Visconti A, Barna-Vetro I (2006) Monoclonal antibody based electrochemical immunosensor for the determination of ochratoxin A in wheat. Talanta 69:1031

    Article  CAS  Google Scholar 

  31. Hokama Y (1991) Immunological analysis of low molecular weight marine toxins. J Toxicol Toxin Rev 10:1

    CAS  Google Scholar 

  32. Bignami GS, Raybould TJG, Sachinvala ND, Grothaus SB, Simpson SB, Lazo CB, Byrnes JB, Moore E, Vann DC (1992) Monoclonal antibody-based enzyme-linked immunoassays for the measurement of palytoxin in biological samples. Toxicon 30:687

    Article  CAS  Google Scholar 

  33. Van Emon JM, Lopez-Avila V (1992) Immunochemical for environmental analysis. Anal Chem 64:79A

    Article  Google Scholar 

  34. Candlish AAG, Stimsom WH, Smith JE (1988) Determination of ochratoxin A by monoclonal antibody based enzyme immunoassay. J Assoc Off Anal Chem 71:961

    CAS  Google Scholar 

  35. Ramakrishna N, Lacey J, Candlish AAG, Smith JE, Goodbrand IA (1990) Monoclonal antibody based enzyme linked immunosorbent assay of aflatoxin B, T-2 toxin and ochratoxin A in barley. J Assoc Off Anal Chem 73:71

    CAS  Google Scholar 

  36. Clarke JR, Marquardt RR, Oosterveld A, Frohlich AA, Madrid FJ, Dawood M (1993) Development of quantitative and sensitive enzyme-linked immunosorbent assay for ochratoxin A using antibodies from the yolk of laying hen. J Agric Food Chem 41:1784

    Article  CAS  Google Scholar 

  37. Barna Vetro L, Solti J, T´eren A, Gyongyosi E, Szabo A, Wolfling J (1996) Sensitive ELISA test for determination of ochratoxin A. Agric Food Chem 44:4071

    Article  CAS  Google Scholar 

  38. Kwak B, Shon D (2000) Detection of ochratoxin A in agricultural commodities using enzyme-linked immunosorbent assay. Food Sci Biotechnol 9:168

    Google Scholar 

  39. Ogert RA, Burans J, O’ Brien T, Ligler FS (1994) Comparative analysis of toxin detection in biological and environmental samples. Proc SPIE Int Soc Opt Eng 2068:151

    CAS  Google Scholar 

  40. Poli MA, Rivera VR, Hewetson JF, Merril GA (1994) Detection of ricin by colorimetric and chemiluminescence ELISA. Toxicon 32:1371

    Article  CAS  Google Scholar 

  41. Wieneke AA, Gilbert RJ (1985) The use of sandwich ELISA for the detection of staphylococcal enterotoxin A in foods from outbreaks of food poisoning. J Hygiene 95:131

    Article  CAS  Google Scholar 

  42. Nielsen P, Koch C, Friis H, Heron I, Prag J, Schmidt J (1987) Double-antibody sandwich enzyme-linked immunosorbent assay for rapid detection of toxin-producing. J Clin Microbiol 25:1280

    CAS  Google Scholar 

  43. Bhatti AR, Siddiqui YM, Micusan VV (1994) Highly sensitive fluorogenic enzyme-linked immunosorbent assay: detection of staphylococcal enlerotoxin B. J Microbiol Meth 19:179

    Article  CAS  Google Scholar 

  44. Doellgast GJ, Beard GA, Bottoms JD, Cheng T, Roh BH, Roman MG, Hall PA, Triscott MX (1994) Enzyme-linked immunosorbent assay-enzyme-linked coagulation assay for detection of antibodies to Clostridium botulinum neurotoxins A, B, and E and solution-phase complexes. J Clin Microbiol 32:105

    CAS  Google Scholar 

  45. Monaci L, Palmisano F (2004) Determination of ochratoxin A in foods: State- of-the-art and analytical challenges. Anal Bioanal Chem 378:96

    Article  CAS  Google Scholar 

  46. Saha D, Acharya D, Roy D, Shrestha D, Dhar TK (2007) Simultaneous enzyme immunoassay for the screening of aflatoxin B-1 and ochratoxin A in chili samples. Anal Chim Acta 584:343

    Article  CAS  Google Scholar 

  47. Sauceda-Friebe JC, Karsunke XYZ, Vazac S, Biselli S, Niessner R, Knopp D (2011) Regenerable immuno-biochip for screening ochratoxin A in green coffee extract using an automated microarray chip reader with chemiluminescence detection. Anal Chim Acta 689:234

    Article  CAS  Google Scholar 

  48. Clarke JR, Marquardt RR, Frohlich AA, Pitura RJ (1994) Quantification of ochratoxin A in swine kidneys by enzyme-linked immunosorbent assay using a simplify sample preparation procedure. J Food Protect 57:991

    CAS  Google Scholar 

  49. Sibanda L, De saeger S, Barna-Vetro I, Van Petheghem CJ (2002) Development of a solid-phase clean-up and portable rapid flow-through enzyme immunoassay for the detection of ochratoxin A in roasted coffee. J Agric Food Chem 50:6964

    Article  CAS  Google Scholar 

  50. De Saeger S, Van Peteghem C (1999) Flowthrough membrane-based enzyme immunoassay for rapid detection of ochratoxin A in wheat. J Food Protect 62:65

    Google Scholar 

  51. Fernandez-Baldo MA, Bertolino FA, Fernandez G, Messina GA, Sanz MI, Raba J (2011) Determination of Ochratoxin A in apples contaminated with Aspergillus ochraceus by using a microfluidic competitive immunosensor with magnetic nanoparticles. Analyst 136:2756

    Article  CAS  Google Scholar 

  52. Liu X-P, Deng Y-J, Jin X-Y, Chen L-G, Jiang J-H, Shen G-L, Yu R-Q (2009) Ultrasensitive electrochemical immunosensor for ochratoxin A using gold colloid-mediated hapten immobilization. Anal Biochem 389:63

    Article  CAS  Google Scholar 

  53. Micheli L, Radoi A, Guarrina R, Massoud R, Bala C, Moscone D, Palleschi G (2004) Disposable immunosensor for the determination of domoic acid in shellfish. Biosens Bioelectron 20:190

    Article  CAS  Google Scholar 

  54. Ammida NHS, Micheli L, Palleschi G (2004) Electrochemical immunosensor for determination of aflatoxin B1 in barley. Anal Chim Acta 520:159

    Article  CAS  Google Scholar 

  55. Stenberg E, Persson B, Roos H, Urbaniczky C (1991) Quantitative determination of surface concentration of protein with surface plasmon resonance by using radiolabeled proteins. J Colloid Interface Sci 143:513

    Article  CAS  Google Scholar 

  56. van der Gaag B, Spath S, Dietrich H, Stigter E, Boonzaaijer G, van Osenbruggen T, Koopal K (2003) Biosensors and multiple mycotoxin analysis. Food Control 14:251

    Article  Google Scholar 

  57. Yu JCC, Lai EPC (2005) Interaction of ochratoxin A with molecularly imprinted polypyrrole film on surface plasmon resonance sensor. React Funct Polym 63:171

    Article  CAS  Google Scholar 

  58. Yuan J, Deng D, Lauren DR, Aguilar M-I, Wu Y (2009) Surface plasmon resonance biosensor for the detection of ochratoxin A in cereals and beverages. Anal Chim Acta 656:63

    Article  CAS  Google Scholar 

  59. Zamfir L-G, Geana I, Bourigua S, Rotariu L, Bala C, Errachid A, Jaffrezic-Renault N (2011) Highly sensitive label-free immunosensor for ochratoxin A based on functionalized magnetic nanoparticles and EIS/SPR detection. Sens Actuat B. 159:178

    Google Scholar 

  60. Sauerbrey G (1959) The use of oscillator for weighing thin layers and for microweighing. Z Phys 155:206

    Article  CAS  Google Scholar 

  61. Auge J, Hauptmann P, Hartmann J, Rosler S, Lucklum R (1995) New design for QCM sensors in liquid. Sens Actuat B 24–25:43–48

    Article  Google Scholar 

  62. Ellis JS, Thompson M (2010) Viscoelastic modelling with interfacial slip of a protein monolayer electrode-adsorbed on an acoustic wave biosensor. Langmuir 26:11558

    Article  CAS  Google Scholar 

  63. Tsai WC, Hsieh CK (2007) QCM-based immunosensor for the determination of ochratoxin A. Anal Lett 40:1979

    Article  CAS  Google Scholar 

  64. Lisdat F, Schäfer D (2008) The use of electrochemical impedance spectroscopy for biosensing. Anal Bioanal Chem 391:1555

    Article  CAS  Google Scholar 

  65. Khan R, Dhayal M (2008) Nanocrystalline bioactive TiO2-chitosan impedimetric immunosensor for ochratoxin-A. Electrochem Commun 10:492

    Article  CAS  Google Scholar 

  66. Khan R, Dhayal M (2009) Chitosan/polyaniline hybrid conducting biopolymer base impedimetric immunosensor to detect Ochratoxin-A. Biosens Bioelectr 24:1700

    Article  CAS  Google Scholar 

  67. Radi A-E, Munoz-Berbel X, Lates V, Marty J-L (2009) Label-free impedimetric immunosensor for sensitive detection of ochratoxin A. Biosens Bioelectr 24:1888

    Article  CAS  Google Scholar 

  68. Ansari AA, Kaushik A, Solanki PR, Malhotra BD (2010) Nanostructured zinc oxide platform for mycotoxin detection. Bioelectrochemistry 77:75

    Article  CAS  Google Scholar 

  69. Kaushik A, Solanki PR, Pandey MK, Kaneto K, Ahmad S, Malhotra BD (2010) Carbon nanotubes chitosan anobiocomposite for immunosensor. Thin Solid Films 519:1160

    Article  CAS  Google Scholar 

  70. Muchindu M, Iwuoha E, Pool E, West N, Jahed N, Baker P, Waryo T, Williams A (2011) Electrochemical ochratoxin A immunosensor system developed on sulfonated polyaniline. Electroanalysis 23:122

    Article  CAS  Google Scholar 

  71. Xiao Y, Piorek BD, Plaxco KW, Heeger AJ (2005) A reagentless, signal-on design for electronic aptamer-based sensors via target-induced strand displacement. J Am Chem Soc 127:17990

    Article  CAS  Google Scholar 

  72. Hianik T, Wang J (2009) Electrochemical aptasensors – recent achievements and perspectives. Electroanalysis 21:1223

    Article  CAS  Google Scholar 

  73. Cheng AKH, Sen D, Yu H-Z (2009) Design and testing of aptamer-based electrochemical biosensors for small molecules and proteins. Bioelectrochemistry 77:1

    Article  CAS  Google Scholar 

  74. Ferapontova EE, Gothelf KV (2011) Recent advances in electrochemical aptamer-based sensors. Curr Org Chem 15:498

    Article  CAS  Google Scholar 

  75. Wei F, Ho C-M (2009) Aptamer-based electrochemical biosensor for Botulinum neurotoxin. Anal Bioanal Chem 393:1943

    Article  CAS  Google Scholar 

  76. Tuerk C, Gold L (1990) Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4 DNA polymerase. Science 249:505

    Article  CAS  Google Scholar 

  77. Elington AD, Szostak JW (1990) In vitro selection of RNA molecules that bind specific ligands. Nature (Lond) 346:818

    Article  Google Scholar 

  78. Cruz-Aguado JA, Penner G (2008) Determination of ochratoxin A with a DNA aptamer. J Agr Food Chem 56:10456

    Article  CAS  Google Scholar 

  79. Zuker M (2003) Mfold web server for nucleic acid folding and hybridization prediction. Nucleic Acids Res 31:3406

    Article  CAS  Google Scholar 

  80. Kikin O, D’Antonio L, Bagga PS (2006) QGRS Mapper: a web-based server for predicting G-quadruplexes in nucleotide sequences. Nucleic Acids Res 34:W676

    Article  CAS  Google Scholar 

  81. Castillo G, Lamberti I, Mosiello L, Hianik, T (2011) Impedimetric DNA aptasensor for sensitive detection of ochratoxin A in a food. Electroanalysis doi:10.1002/elan.201100485.

    Google Scholar 

  82. Lamberti I, Mosiello L, Hianik T (2011) Development of thickness shear mode biosensor based on DNA aptamers for detection of ochratoxin A. Chem Sensors 1:11

    Google Scholar 

  83. Poniková S, Tlučková K, Antalík M, Víglaský V, Hianik T (2011) The circular dichroism and differential scanning calorimetry study of the properties of DNA aptamer dimers. Biophys Chem 155:29

    Article  Google Scholar 

  84. Yang C, Wang Y, Marty J-L, Yang X (2011) Aptamer-based colorimetric biosensing of ochratoxin A using unmodified gold nanoparticles indicator. Biosens Bioelectron 26:2724

    Article  CAS  Google Scholar 

  85. Wang ZP, Duan N, Hun X, Wu SJ (2010) Electrochemiluminescent aptamer biosensor for the determination of ochratoxin A at a gold-nanoparticles-modified gold electrode using N-(aminobutyl)-N-ethylisoluminol as a luminescent label. Anal Bioanal Chem 398:2125

    Article  CAS  Google Scholar 

  86. Wu S, Duan N, Wang Z, Wang H (2011) Aptamer-functionalized magnetic nanoparticle-based bioassay for the detection of ochratoxin A using upconversion nanoparticles as labels. Analyst 136:2306

    Article  CAS  Google Scholar 

  87. Kuang H, Chen W, Xu D, Xu L, Zhu Y, Liu L, Chu H, Peng C, Xu C, Zhu S (2010) Fabricated aptamer-based electrochemical “signal-off” sensor of ochratoxin A. Biosens Bioelectron 26:710

    Article  CAS  Google Scholar 

  88. Barthelmebs L, Hayat A, Limiadi AW, Marty J-L, Noguer T (2011) Electrochemical DNA aptamer-based biosensor for OTA detection, using superparamagnetic nanoparticles. Sens Actuat B 156:932

    Article  Google Scholar 

  89. Prieto-Simon B, Campas M, Marty J-L, Noguer T (2008) Novel highly-performing immunosensor-based strategy for ochratoxin A detection in wine samples. Biosens Bioelectron 23:995

    Article  CAS  Google Scholar 

  90. Bonel L, Vidal JC, Duato P, Castillo JR (2011) An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer. Biosens Bioelectron 26:3254

    Article  CAS  Google Scholar 

  91. Bonel L, Vidal JC, Duato P, Castillo JR (2010) An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer. Anal Methods 2:335

    Article  CAS  Google Scholar 

  92. Castillo G, Lamberti I, Mosiello L, Hianik T (2012) High-sensitive impedimetric aptasensor for detection ochratoxin A in food. In: Di Natale C (ed) Sensors and microsystems. Lecture Notes in Electrical Engineering. Springer, New York/Heilderberg doi:10.1007/978-1-4614-0935-9_6.

  93. Prabhakar P, Matharu Z, Malhotra BD (2011) Polyaniline Langmuir-Blodgett film based aptasensor for ochratoxin A detection. Biosens Bioelectron 26:4006

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The work was supported by the Slovak Research and Development Agency (contracts No. APVV-0410-10, LPP-0341-09).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tibor Hianik .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer Science+Business Media B.V.

About this paper

Cite this paper

Hianik, T. (2012). Biosensors for Detection of Ochratoxin A. In: Nikolelis, D. (eds) Portable Chemical Sensors. NATO Science for Peace and Security Series A: Chemistry and Biology. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-2872-1_10

Download citation

Publish with us

Policies and ethics