Skip to main content

Automated imunoanalysis systems for monitoring mammalian cell cultivation processes

  • Chapter
Cell Culture Engineering IV

Abstract

Two different automated immunoanalysis systems are presented. Both are based on the principles of flow-injection analysis and were developed to provide reliable, rapid monitoring of relevant proteins in animal cell cultivation processes. One system uses a turbidimetric analysis, and the other employs a heterogeneous chemistry with immobilized immunocomponents. For both systems, the analysis time is in the range of a few minutes, and a complete analysis cycle, including triplicate analyses and various washing steps, is in the range of 20–30 minutes. Samples from cultivation processes can be analyzed directly without dilution. Quantitation of proteins such as rt-PA or monoclonal antibodies can be performed over an analyte concentration range of 1–1000 mg/L. Both systems were compared to conventional ELISA assays on microtiter plates. The turbidimetric analysis system also included a biosensor for simultaneous glucose determination.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Brandes W, Maschke HE, Scheper T (1993) Specific flow injection sandwich binding assay for IgG using protein a and a fusion protein, Anal. Chem. 65: 3368–3371.

    Article  CAS  PubMed  Google Scholar 

  • Danielsson B, Larson PO (1990) Specific monitoring of Chromatographie procedures, Trend Anal. Chem. 91: 223–227.

    Article  Google Scholar 

  • Dullau T, Schiigerl K (1991) Process analysis and control by enzyme-FIA-systems, in: Flow injection analysis (FIA) based on enzymes or antibodies (ed.: R.D: Schmid), GBF Monographs, Vol. 14, Weinheim: 27–39.

    CAS  Google Scholar 

  • Freitag R, Scheper T, Schügerl K (1991) Development of a tur-bidimetric immunoassay for on-line monitoring of proteins in cultivation processes, Enzyme Microb. Techno!. 13: 969–975.

    Article  CAS  Google Scholar 

  • Freitag R, Scheper T, Spreinat A, Antranikian G (1991b) On-line monitoring of pullulanase production during continuous culture of Clostridium thermosuifurogenes. Appl. Microbiol. Biotechnol. 35: 471–476.

    Article  CAS  Google Scholar 

  • Mattiasson B, Hakanson H (1992) Immunochemically based assays for process control, in: Modern Biochemical Engineering (ed A. Fiechter) Advances in Biochem. Eng. Biotechnol., Vol. 46, Springer Verlag Berlin, pp: 81–101.

    Chapter  Google Scholar 

  • Middendorf C, Schulze B, Freitag R, Scheper T, Howaldt M, Hoffmann H (1993) On-line immunoanalysis for bioprocess control, J. Biotechnol. 3: 395–403.

    Google Scholar 

  • Miyabayashi A, Mattiasson B (1990) A dual streaming potential device used as an affinity sensor for monitoring hybridomacell cultivation, Anal. Biochem. 184: 165–171.

    Article  CAS  PubMed  Google Scholar 

  • Nilsson M, Hankanson H, Mattiasson B (1991) Flow-injection ELISA for process monitoring and control, Anal. Chim. Acta 249: 163–168.

    Article  CAS  Google Scholar 

  • Ruzicka J, Hansen EH (1988) Flow injection analysis (2nd edition), Wiley & Sons, New York.

    Google Scholar 

  • Scheper T, Reardon KF (1991) Sensors in Biotechnology in: Sensors Vol. 2(2) (eds.: W Göpel, J Hesse, JN Memel) VCH Weinheim: 1024-1046.

    Google Scholar 

  • Scheper T, Brandes W, Maschkel H, Plötz F, Muller C (1993) Two FIA-based biosensor systems studied for bioprocess monitoring, J. Biotechnol. 31: 345–356.

    Article  CAS  PubMed  Google Scholar 

  • Stöcklein W, Jäger V, Schmid RD (1992) Monitoring of mouse immunoglobulin G by flow injection analytical affinity chromatography, Anal. Chim. Acta 245(1): 1–6.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1994 Springer Science+Business Media Dordrecht

About this chapter

Cite this chapter

Schulze, B., Middendorf, C., Reinecke, M., Scheper, T., Noé, W., Howaldt, M. (1994). Automated imunoanalysis systems for monitoring mammalian cell cultivation processes. In: Buckland, B.C., Aunins, J.G., Bibila, T.A., Hu, WS., Robinson, D.K., Zhou, W. (eds) Cell Culture Engineering IV. Current Applications of Cell Culture Engineering, vol 1. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-0257-5_29

Download citation

  • DOI: https://doi.org/10.1007/978-94-011-0257-5_29

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-4114-0

  • Online ISBN: 978-94-011-0257-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics