Summary
This report describes the quantification of chromosomal aberrations by flow cytometry. Both homogeneously and heterogeneously occurring chromosome aberrations were studied. Homogeneously occurring aberrations were noted in chromosomes isolated from human colon carcinoma (LoVo) cells, stained with Hoechst 33258 and chromo-mycin A3 and analyzed using dual beam flow cytometry. The resulting bivariate flow karyotype showed a homogeneously occurring marker chromosome of intermediate size. Heterogeneously occurring aberrations were quantified by slit-scan flow cytometry in chromosomes isolated from control and irradiated Chinese hamster cells and stained with propidium iodide. Heterogeneously occurring dicentric chromosomes were detected by their shapes (two centromeres). The frequencies of such chromosomes estimated by slit-scan flow cytometry correlated well with the frequencies determined by visual microscopy.
Work performed under the auspices of the U.S. Department of Energy by the Lawrence Livermore National Laboratory under contract number W-7405-ENG-48 with support from USPHS grants HD 17665 and GH 25076.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Aten J, Kipp JBA, Barendsen GW (1980) Flow-cytofluorometric determination of damage to chromosomes from x-irradiated Chinese hamster cells. In: Laerum O, Lindmo T, Thorud E (eds) Flow Cytometry IV, Universitetsforlaget, p 287–292
Carrano AV, Gray JW, Langlois RG, Burkhart-Schultz K, Van Dilla MA (1979) Measurement and purification of human chromosomes by flow cytometry. Proc Natl Acad Sci USA 76:1382–1384
Carrano AV, Gray JW, Moore II DH, Minkler J, Mayall BH, Van Dilla MA, Mendelsohn ML (1976) Purification of the chromosomes of the Indian muntjac by flow sorting. J Histochem Cytochem 24:348–354
Cram LS, Arndt-Jovin DJ, Grimwade BG, Jovin TM (1979) Fluorescence polarization and pulse width analysis of chromosomes by a flow system. J Histochem Cytochem 27:445–453
Dean PN, Pinkel D (1978) High resolution dual laser flow cytometry. J Histochem Cytochem 26: 622–627
Disteche CM, Carrano AV, Ashworth LH, Burkhart-Schultz K, Latt SA (1981) Flow sorting of the cattanach x-chromosome in an active or inactive state. Cytogenet Cell Genets 29:189–197
Drewinko B, Romsdahl M, Yang L, Ahern M, Trujillo J (1982) Establishment of a human carcino-embryonic antigen-producing colon adenocarcinoma cell line. Cancer Res 36:467–475
Gray JW, Carrano AV, Moore II DH, Steinmetz LL, Minkler J, Mayall BH, Mendelsohn ML, Van Dilla MA (1975a) High-speed quantitative karyotyping by flow microfluorometry. Clin Chem 21:1258–1262
Gray JW, Carrano AV, Steinmetz LL, Van Dilla MA, Moore II DH, Mayall BH, Mendelsohn ML (1975b) Chromosome measurement and sorting by flow systems. Proc Natl Acad Sci USA 72: 1231–1234
Gray JW, Langlois RG, Carrano AV, Burkhart-Schultz K, Van Dilla MA (1979a) High resolution chromosome analysis: One and two parameter flow cytometry. Chromosoma 73:9–27
Gray JW, Lucas J, Pinkel D, Peters D, Ashworth L, Van Dilla MA (1980) Slit scan flow cytometry: Analysis of Chinese hamster M3–1 chromosomes. In: Laerum OD, Lindmo T, Thorud E (eds) Flow Cytometry IV, Universitetsforlaget, Bergen Norway, p 485–491
Gray JW, Peters D, Merrill JT, Martin R, Van Dilla MA (1979b) Slit scan flow cytometry of mammalian chromosomes. J Histochem Cytochem 27:441–444
Langlois R, Yu L-C, Gray JW, Carrano AV (1982) Quantitative karyotyping of human chromosomes by flow cytometry. Proc Natl Acad Sci USA 79:7876–7880
Langlois RG, Carrano VA, Gray JW, Van Dilla MA (1980) Cytochemical studies of metaphase chromosomes by flow cytometry. Chromosoma 77:229–251
Lloyd DC (1983) An overview of radiation dosimetry by conventional cytogenetic methods. This volume.
Stöhr M, Hutter K-J, Frank M, Futterman G, Goerttler K (1980) A flow cytometric study of chromosomes from rat kangaroo and Chinese hamster cells. Histochemistry 67:179–190
Stubblefield E, Deaven LL, Cram LS (1975) Flow microfluorometric analysis of isolated Chinese hamster chromosomes. Exp Cell Res 94:464–468
Young BD, Ferguson-Smith MA, Sillar R, Boyd E (1981) High-resolution analysis of human peripheral lymphocyte chromosomes by flow cytometry. Proc Natl Acad Sci USA 78:7727–7731
Yu L-C, Aten J, Gray JW, Carrano AV (1981) Human chromosome isolation from short-term lymphocyte culture for flow cytometry. Nature 293:154–155
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1984 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Gray, J.W., Lucas, J., Yu, L.C., Langlois, R. (1984). Flow Cytometric Detection of Aberrant Chromosomes. In: Eisert, W.G., Mendelsohn, M.L. (eds) Biological Dosimetry. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-69334-2_3
Download citation
DOI: https://doi.org/10.1007/978-3-642-69334-2_3
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-12790-1
Online ISBN: 978-3-642-69334-2
eBook Packages: Springer Book Archive