Abstract
The imaging of gliomas and metastases by 3D ultrasound has been evaluated by comparing image findings and histopathological results. Biopsies have been taken prior to resection and close to the tumour border as shown in the ultrasound images. The tumour border shown in the ultrasound images was verified by an edge detection algorithm using the Sobel method. Ultrasound images, with the biopsy position indicated, have been evaluated and compared to the histhopathology of the corresponding biopsy. The degree of match between image evaluations and histopathology should reflect the ability of 3D ultrasound to image size and location of tumours correctly. The image slices of intraoperative 3D ultrasound are also compared to corresponding image slices of preoperative MR data (Tl and T2). The preliminary results show that intraoperative 3D ultrasound provides accurate information about tumour border and location and may accordingly be used for guiding surgical procedures. For gliomas the histopathologic match for the intraoperative 3D ultrasound is better than the corresponding match for the preoperative MR data.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Knauth, M., Wirtz C.R., Tronnier V.M., Aras N., Kunze S., Sartor K., Intraoperative MR Imaging Increases the Extent of Tumor Resection in Patients with High-Grade Gliomas. AJNR Am J Neororadiol, 1999. 20: p. 1642-1646.
Le Roux, P.D., Berger M.S., Wang K., Mack L.A., Ojemann G.A., Low grade gliomas: comparison of intraoperative ultrasound characteristics with preoperative imaging studies. Journal of Neuro-Oncology, 1992. 13: p. 189-198.
. Woydt, M., Krone A., Becker G., Schmidt K., Roggendorf W., Roosen K., Correlation of Intra-operative Ultrasound with Histopathologic Findings After Tumour Resection in Supratentorial Gliomas. Acta Neurochir (Wien), 1996. 138: p. 1391-1398.
Unsgaard, G., Ommedal S., Muller T. Gronningsaeter Aa., Nagelhus Hernes T.A., Neuronavigation by three-dimensional ultrasound: Initial experience during brain tumor surgery. Neurosurgery, 2002, 50, April
Wirtz, C.R., Knauth M., Staubert A., Bonsanto M., Sartor K., Kunze S., Tronnier V.M., Clinical Evaluation and Follow-up Results for Intraoperative Magnetic Resonance Imaging in Neurosurgery. Neurosurgery, 2000. 46(5): p. 1112-1122.
. Gronningsaeter, Aa., Kleven A., Ommedal S., Aarseth T.E., Lindseth F., Lango T., Unsgaard G., SonoWand, an Ultrasound-based Neuronavigation System. Neurosurgery, 2000. 47(6): p. 1373-1380.
Lango T., Bang, J., Lindseth F., Nagelhus Hernes, T.A., Accuracy evaluation of a 3D ultrasound-based neuronavigation system. Proc of the 16th International Congress and Exhibition in Computer Assisted Radiology and Surgery, (CARS2002) Paris June 27-30, 2002
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Selbekk, T. et al. (2002). Neurosurgical biopsies guided by 3D ultrasound - comparison of image evaluations and histopathological results. In: Lemke, H.U., Inamura, K., Doi, K., Vannier, M.W., Farman, A.G., Reiber, J.H.C. (eds) CARS 2002 Computer Assisted Radiology and Surgery. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-56168-9_22
Download citation
DOI: https://doi.org/10.1007/978-3-642-56168-9_22
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-62844-3
Online ISBN: 978-3-642-56168-9
eBook Packages: Springer Book Archive