Abstract
Boron neutron-capture therapy uses the chemical delivery of specific boron compounds to neoplastic tissue in combination with thermal neutrons to produce an enhanced radiation dose in the tumor. The nuclear fission reaction when 10B is irradiated with slow neutrons releases relatively large amounts of high linear energy transfer radiation through its fission products 7Li and stripped helium nuclei. The short range of these particles (approximately 10 μm) theoretically restricts the radiation dose to tumor cells. Because of the rapid attenuation of thermal neutrons in tissue, this treatment modality needs surgical techniques to expose the tumor directly to the thermal neutron beam (Hatanaka et al. 1991). On the other hand, neutrons of all energies become thermalized by their interaction with the target material. Hence, during fast-neutron therapy, low-energy neutrons are present in tissue. Since 1978 a compact cyclotron has been used at the Essen University Hospital for fast-neutron therapy. The neutrons are produced by bombarding a beryllium target with 14 MeV deuterons. The poor depth dose distribution of this beam (median energy 5.7 MeV) limits the treatment of deep-seated tumors (Rassow 1982). An enhancement of the dose at depth could be obtained by neutron-capture reactions if there is a sufficient flux of thermalized neutrons derived from fast neutrons after slowing down in tissue.
This research was supported in part by the Deutsche Forschungsgemeinschaft.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Barth RF, Fairchild RG, Soloway AH (1990) Boron neutron capture therapy for cancer. Sci Am 262: 68–73
Hatanaka H, Yasukochi H, Sano K (1991) Boron neutron capture therapy for brain tumours. In: Abe M, Takahashi M (eds) Intraoperative radiation therapy. Pergamon, New York, pp 153–155
Pöller F, Sauerwein W, Rau D, Wagner FM, Olthoff K, Rassow J, Sack H (1990) Neutronenfluenzmessungen im d(14) + Be-Neutronenstrahlungsfeld des Zyklotrons in Essen. Strahlenther Onkol 166: 426–429
Rassow J (1982) Medical cyclotron facilities useful tools for clinical therapy, diagnosis and analysis. Proc Int Symp Appl Technol J Rad 1: 47–100
Sauerwein W, Ziegler W, Szypniewski H, Streffer C (1990) Boron neutron capture therapy (BNCT) using fast neutrons: effects in two human tumour cell lines. Strahlenther Onkol 166: 26–29
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1992 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Sauerwein, W., Pöller, F., Rassow, J., Sack, H. (1992). Enhancement of the Absorbed Dose in a d(14) + Be Fast-Neutron Beam by 10B Neutron-Capture Therapy. In: Breit, A., Heuck, A., Lukas, P., Kneschaurek, P., Mayr, M. (eds) Tumor Response Monitoring and Treatment Planning. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-48681-4_132
Download citation
DOI: https://doi.org/10.1007/978-3-642-48681-4_132
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-54783-9
Online ISBN: 978-3-642-48681-4
eBook Packages: Springer Book Archive