Modularity in total hip arthroplasty (THA) allows surgeons to optimize implant reconstruction to patient anatomy intraoperatively. Dual-modular femoral neck-stem or “dual-taper” THA implants possess interchangeable necks, providing additional modularity at the neck-stem interface. Modular taper designs have the potential to allow precise reconstruction of center of rotation of the hip by facilitating adjustments in limb length, femoral neck version, and hip offset in order to optimize hip biomechanical parameters. Recently, there is increasing concern regarding this stem design as a result of the growing numbers of clinical failures due to fretting and corrosion at neck-stem taper junction, in a process that has been described as mechanically assisted crevice corrosion (MACC). Implant, surgical, and patient factors have been identified as likely contributing factors responsible for taper corrosion in dual-modular neck-stem THA. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-modular neck-stem THAs as early recognition and diagnosis will ensure prompt and appropriate treatment. As painful dual-modular neck-stem THAs have various intrinsic and extrinsic causes, patients should be evaluated utilizing systematic risk stratification algorithms. Although specialized test such as metal ion analysis and cross-sectional imaging modalities such as MARS MRI and ultrasound should be used to optimize clinical decision making, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. Further research is required to gain understanding of implant, surgical, and patient risk factors associated with taper corrosion in dual-modular neck-stem THA.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 79.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 99.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 129.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Srinivasan A, Jung E, Levine BR. Modularity of the femoral component in total hip arthroplasty. J Am Acad Orthop Surg. 2012;20(4):214–22.

    Article  PubMed  Google Scholar 

  2. Cameron HU, Keppler L, McTighe T. The role of modularity in primary total hip arthroplasty. J Arthroplast. 2006;21(4 Suppl 1):89–92.

    Article  Google Scholar 

  3. Restrepo C, Mashadi M, Parvizi J, Austin MS, Hozack WJ. Modular femoral stems for revision total hip arthroplasty. Clin Orthop Relat Res. 2011;469(2):476–82.

    Article  PubMed  Google Scholar 

  4. Krishnan H, Krishnan SP, Blunn G, Skinner JA, Hart AJ. Modular neck femoral stems. Bone Joint J. 2013;95-B(8):1011–21.

    Article  CAS  PubMed  Google Scholar 

  5. Kotwal RS, Ganapathi M, John A, Maheson M, Jones SA. Outcome of treatment for dislocation after primary total hip replacement. J Bone Joint Surg Br. 2009;91(3):321–6.

    Article  CAS  PubMed  Google Scholar 

  6. Imamura M, Munro NA, Zhu S, Glazener C, Fraser C, Hutchison J, et al. Single mini-incision total hip replacement for the management of arthritic disease of the hip: a systematic review and meta-analysis of randomized controlled trials. J Bone Joint Surg Am. 2012;94(20):1897–905.

    Article  PubMed  Google Scholar 

  7. Berry DJ. Utility of modular implants in primary total hip arthroplasty. J Arthroplast. 2014;29(4):657–8.

    Article  Google Scholar 

  8. Sotereanos NG, Sauber TJ, Tupis TT. Modular femoral neck fracture after primary total hip arthroplasty. J Arthroplasty. 2013;28(1):196e7–9.

    Article  Google Scholar 

  9. Ellman MB, Levine BR. Fracture of the modular femoral neck component in total hip arthroplasty. J Arthroplasty. 2013;28(1):196e1–5.

    Article  Google Scholar 

  10. Kop AM, Keogh C, Swarts E. Proximal component modularity in THA—at what cost? An implant retrieval study. Clin Orthop Relat Res. 2012;470(7):1885–94.

    Article  CAS  PubMed  Google Scholar 

  11. Skendzel JG, Blaha JD, Urquhart AG. Total hip arthroplasty modular neck failure. J Arthroplasty. 2011;26(2):338e1–4.

    Article  Google Scholar 

  12. Sporer SM, DellaValle C, Jacobs J, Wimmer M. A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006;21(6):918–21.

    Article  PubMed  Google Scholar 

  13. Esposito CI, Wright TM, Goodman SB, Berry DJ, Clinical B. Bioengineering Study Groups from Carl TBW. What is the trouble with trunnions? Clin Orthop Relat Res. 2014;472(12):3652–8.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Cooper HJ, Urban RM, Wixson RL, Meneghini RM, Jacobs JJ. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013;95(10):865–72.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Toni A, Sudanese A, Ciaroni D, Dallari D, Greggi T, Giunti A. Anatomical ceramic arthroplasty (AN.C.A.): preliminary experience with a new cementless prosthesis. Chir Organi Mov. 1990;75(1):81–97.

    CAS  PubMed  Google Scholar 

  16. Lombardi Jr AV. Case studies in management of THA failure secondary to taper corrosion, modular junctions and metal-on-metal bearings. J Arthroplast. 2014;29(4):663–7.

    Article  Google Scholar 

  17. Meftah M, Haleem AM, Burn MB, Smith KM, Incavo SJ. Early corrosion-related failure of the rejuvenate modular total hip replacement. J Bone Joint Surg Am. 2014;96(6):481–7.

    Article  PubMed  Google Scholar 

  18. Molloy DO, Munir S, Jack CM, Cross MB, Walter WL, Walter Sr WK. Fretting and corrosion in modular-neck total hip arthroplasty femoral stems. J Bone Joint Surg Am. 2014;96(6):488–93.

    Article  PubMed  Google Scholar 

  19. Restrepo C, Ross D, Restrepo S, Heller S, Goyal N, Moore R, et al. Adverse clinical outcomes in a primary modular neck/stem system. J Arthroplast. 2014;29(9 Suppl):173–8.

    Article  Google Scholar 

  20. Ghanem E, Ward DM, Robbins CE, Nandi S, Bono JV, Talmo CT. Corrosion and adverse local tissue reaction in one type of modular neck stem. J Arthroplasty. 2015;30(10):1787–93.

    Article  PubMed  Google Scholar 

  21. Walsh CP, Hubbard JC, Nessler JP, Markel DC. Revision of recalled modular neck rejuvenate and ABG femoral implants. J Arthroplast. 2015;30(5):822–6.

    Article  Google Scholar 

  22. Mathiesen EB, Lindgren JU, Blomgren GG, Reinholt FP. Corrosion of modular hip prostheses. J Bone Joint Surg Br. 1991;73(4):569–75.

    CAS  PubMed  Google Scholar 

  23. Jacobs JJ, Gilbert JL, Urban RM. Corrosion of metal orthopaedic implants. J Bone Joint Surg Am. 1998;80(2):268–82.

    Article  CAS  PubMed  Google Scholar 

  24. Rostoker W, Galante JO, Lereim P. Evaluation of couple/crevice corrosion by prosthetic alloys under in vivo conditions. J Biomed Mater Res. 1978;12(6):823–9.

    Article  CAS  PubMed  Google Scholar 

  25. Kummer FJ, Rose RM. Corrosion of titanium/cobalt-chromium alloy couples. J Bone Joint Surg Am. 1983;65(8):1125–6.

    Article  CAS  PubMed  Google Scholar 

  26. Pivec R, Meneghini RM, Hozack WJ, Westrich GH, Mont MA. Modular taper junction corrosion and failure: how to approach a recalled total hip arthroplasty implant. J Arthroplast. 2014;29(1):1–6.

    Article  Google Scholar 

  27. https://aoanjrr.dmac.adelaide.edu.au/documents/10180/217745/Hip%20and%20Knee%20Arthroplasty. Accessed 30 Nov 2015.

  28. Frei H, Oxland TR, Rathonyi GC, Nolte LP. The effect of nucleotomy on lumbar spine mechanics in compression and shear loading. Spine. 2001;26(19):2080–9.

    Article  CAS  PubMed  Google Scholar 

  29. Tan SC, Teeter MG, Del Balso C, Howard JL, Lanting BA. Effect of taper design on Trunnionosis in metal on polyethylene Total hip arthroplasty. J Arthroplast. 2015;30(7):1269–72.

    Article  Google Scholar 

  30. Panagiotidou A, Meswania J, Hua J, Muirhead-Allwood S, Hart A, Blunn G. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. J Orthop Res. 2013;31(12):2032–9.

    Article  PubMed  Google Scholar 

  31. Collier JP, Surprenant VA, Jensen RE, Mayor MB. Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems. Clin Orthop Relat Res. 1991;271:305–12.

    Google Scholar 

  32. Kurtz SM, Kocagoz SB, Hanzlik JA, Underwood RJ, Gilbert JL, MacDonald DW, et al. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Clin Orthop Relat Res. 2013;471(10):3270–82.

    Article  PubMed  PubMed Central  Google Scholar 

  33. De Martino I, Assini JB, Elpers ME, Wright TM, Westrich GH. Corrosion and fretting of a modular hip system: a retrieval analysis of 60 rejuvenate stems. J Arthroplast. 2015;30(8):1470–5.

    Article  Google Scholar 

  34. Nassif NA, Nawabi DH, Stoner K, Elpers M, Wright T, Padgett DE. Taper design affects failure of large-head metal-on-metal total hip replacements. Clin Orthop Relat Res. 2014;472(2):564–71.

    Article  PubMed  Google Scholar 

  35. Langton DJ, Sidaginamale R, Lord JK, Nargol AV, Joyce TJ. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res. 2012;1(4):56–63.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  36. Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002;401:149–61.

    Article  Google Scholar 

  37. Burroughs BR, Muratoglu OK, Bragdon CR, Wannomae KK, Christensen S, Lozynsky AJ, et al. In vitro comparison of frictional torque and torsional resistance of aged conventional gamma-in-nitrogen sterilized polyethylene versus aged highly crosslinked polyethylene articulating against head sizes larger than 32 mm. Acta Orthop. 2006;77(5):710–8.

    Article  PubMed  Google Scholar 

  38. Higgs GB, Hanzlik JA, MacDonald DW, Gilbert JL, Rimnac CM, Kurtz SM, et al. Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study. J Arthroplast. 2013;28(8 Suppl):2–6.

    Article  Google Scholar 

  39. Jauch SY, Huber G, Hoenig E, Baxmann M, Grupp TM, Morlock MM. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis. J Biomech. 2011;44(9):1747–51.

    Article  CAS  PubMed  Google Scholar 

  40. Grupp TM, Weik T, Bloemer W, Knaebel HP. Modular titanium alloy neck adapter failures in hip replacement—failure mode analysis and influence of implant material. BMC Musculoskelet Disord. 2010;11:3.

    Article  PubMed  PubMed Central  Google Scholar 

  41. Shulman RM, Zywiel MG, Gandhi R, Davey JR, Salonen DC. Trunnionosis: the latest culprit in adverse reactions to metal debris following hip arthroplasty. Skelet Radiol. 2015;44(3):433–40.

    Article  Google Scholar 

  42. McGrory BJ, MacKenzie J, Babikian G. A high prevalence of corrosion at the head-neck taper with contemporary Zimmer non-cemented femoral hip components. J Arthroplast. 2015;30(7):1265–8.

    Article  Google Scholar 

  43. Ebramzadeh E, Campbell P, Tan TL, Nelson SD, Sangiorgio SN. Can wear explain the histological variation around metal-on-metal total hips? Clin Orthop Relat Res. 2015;473(2):487–94.

    Article  PubMed  Google Scholar 

  44. Perino G, Ricciardi BF, Jerabek SA, Martignoni G, Wilner G, Maass D, et al. Implant based differences in adverse local tissue reaction in failed total hip arthroplasties: a morphological and immunohistochemical study. BMC Clin Pathol. 2014;14:39.

    Article  PubMed  PubMed Central  Google Scholar 

  45. Kolatat K, Perino G, Wilner G, Kaplowitz E, Ricciardi BF, Boettner F, et al. Adverse local tissue reaction (ALTR) associated with corrosion products in metal-on-metal and dual modular neck total hip replacements is associated with upregulation of interferon gamma-mediated chemokine signaling. J Orthop Res. 2015;33(10):1487–97.

    Article  CAS  PubMed  Google Scholar 

  46. Pattyn CA, Lauwagie SN, Verdonk RC. Whole blood metal ion concentrations in correlation with activity level in three different metal-on-metal bearings. J Arthroplast. 2011;26(1):58–64.

    Article  Google Scholar 

  47. Kwon YM, Jacobs JJ, MacDonald SJ, Potter HG, Fehring TK, Lombardi AV. Evidence-based understanding of management perils for metal-on-metal hip arthroplasty patients. J Arthroplasty. 2012;27(8 Suppl):20–5.

    Article  PubMed  Google Scholar 

  48. Kwon YM, Lombardi AV, Jacobs JJ, Fehring TK, Lewis CG, Cabanela ME. Risk stratification algorithm for Management of Patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg. 2014;96(1):e4.

    Article  PubMed  Google Scholar 

  49. Kwon YM, Fehring TK, Lombardi AV, Barnes CL, Cabanela ME, Jacobs JJ. Risk stratification algorithm for management of patients with dual modular taper total hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons and the Hip Society. J Arthroplast. 2014;29(11):2060–4.

    Article  Google Scholar 

  50. Melvin JS, Karthikeyan T, Cope R, Fehring TK. Early failures in total hip arthroplasty—a changing paradigm. J Arthroplast. 2014;29(6):1285–8.

    Article  Google Scholar 

  51. Judd KT, Noiseux N. Concomitant infection and local metal reaction in patients undergoing revision of metal on metal total hip arthroplasty. Iowa Orthop J. 2011;31:59–63.

    PubMed  PubMed Central  Google Scholar 

  52. Natu S, Sidaginamale RP, Gandhi J, Langton DJ, Nargol AV. Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplasties. J Clin Pathol. 2012;65(5):409–18.

    Article  PubMed  Google Scholar 

  53. Paul HY, Cross MB, Moric M, Levine BR, Sporer SM, Paprosky WG, et al. Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res. 2015;473(2):498–505.

    Article  Google Scholar 

  54. Deirmengian C, Kardos K, Kilmartin P, Cameron A, Schiller K, Booth Jr RE, et al. The alpha-defensin test for periprosthetic joint infection outperforms the leukocyte esterase test strip. Clin Orthop Relat Res. 2015;473(1):198–203.

    Article  PubMed  Google Scholar 

  55. Gill IP, Webb J, Sloan K, Beaver RJ. Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. J Bone Joint Surg Br. 2012;94(7):895–900.

    Article  CAS  PubMed  Google Scholar 

  56. Plummer DR, Berger RA, Paprosky WG, Sporer SM, Jacobs JJ, Della Valle CJ. Diagnosis and management of adverse local tissue reactions secondary to corrosion at the head-neck junction in patients with metal on polyethylene bearings. J Arthroplasty. 2016;31(1):264–8.

    Article  PubMed  Google Scholar 

  57. Kretzer JP, Jakubowitz E, Krachler M, Thomsen M, Heisel C. Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop. 2009;33(6):1531–6.

    Article  PubMed  PubMed Central  Google Scholar 

  58. Barlow BT, Assini J, Boles J, Lee YY, Westrich GH. Short-term metal ion trends following removal of recalled modular neck femoral stems. J Arthroplast. 2015;30(7):1191–6.

    Article  Google Scholar 

  59. Garbuz DS, Hargreaves BA, Duncan CP, Masri BA, Wilson DR, Forster BB. The John Charnley award: diagnostic accuracy of MRI versus ultrasound for detecting pseudotumors in asymptomatic metal-on-metal THA. Clin Orthop Relat Res. 2014;472(2):417–23.

    Article  PubMed  Google Scholar 

  60. Siddiqui IA, Sabah SA, Satchithananda K, Lim AK, Cro S, Henckel J, et al. A comparison of the diagnostic accuracy of MARS MRI and ultrasound of the painful metal-on-metal hip arthroplasty. Acta Orthop. 2014;85(4):375–82.

    Article  PubMed  PubMed Central  Google Scholar 

  61. Hayter CL, Potter HG, Su EP. Imaging of metal-on-metal hip resurfacing. Orthop Clin North Am. 2011;42(2):195–205. viii

    Article  PubMed  Google Scholar 

  62. Kwon YM. Cross-sectional imaging in evaluation of soft tissue reactions secondary to metal debris. J Arthroplasty. 2014;29(4):653–6.

    Article  PubMed  Google Scholar 

  63. Chang EY, McAnally JL, Van Horne JR, Van Horne JG, Wolfson T, Gamst A, et al. Relationship of plasma metal ions and clinical and imaging findings in patients with ASR XL metal-on-metal Total hip replacements. J Bone Joint Surg. 2013;95(22):2015–20.

    Article  PubMed  Google Scholar 

  64. Masri BA, Mitchell PA, Duncan CP. Removal of solidly fixed implants during revision hip and knee arthroplasty. J Am Acad Orthop Surg. 2005;13(1):18–27.

    Article  PubMed  Google Scholar 

  65. Walsh CP, Hubbard JC, Nessler JP, Markel DC. MRI Findings Associated with Recalled Modular Femoral Neck Rejuvenate and ABG Implants. J Arthroplasty. 2015;30(11):2021–6.

    Article  PubMed  Google Scholar 

  66. Burge AJ, Gold SL, Lurie B, Nawabi DH, Fields KG, Koff MF, et al. MR imaging of adverse local tissue reactions around rejuvenate modular dual-taper stems. Radiology. 2015;141967

    Google Scholar 

  67. Nganbe M, Khan U, Louati H, Speirs A, Beaule PE. In vitro assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements. J Biomed Mater Res B Appl Biomater. 2011;97(1):132–8.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Young-Min Kwon MD, PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this chapter

Cite this chapter

Liow, M.H.L., Kwon, YM. (2017). Complications of Modular Neck-Stems. In: Abdel, M., Della Valle, C. (eds) Complications after Primary Total Hip Arthroplasty. Springer, Cham. https://doi.org/10.1007/978-3-319-54913-2_16

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-54913-2_16

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-54911-8

  • Online ISBN: 978-3-319-54913-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics