Skip to main content

Highly Cross-Linked Polyethylene Bearing

  • Chapter
  • First Online:
Advances in Specialist Hip Surgery
  • 470 Accesses

Abstract

Total hip arthroplasty (THA) is the most useful treatment in symptomatic patients with late-stage osteonecrosis of the femoral head (ONFH). Unique features of ONFH such as altered bone remodeling and high prevalence of younger patients may compromise the outcome after THA. Although recent improvements in the implant design, prosthesis fixation, and surgical technique have led to favorable outcomes after THA in patients with ONFH, the optimal choice of the bearing couple is of utmost importance for implant survival in young patients, who might outlive the prosthetic joint. Highly cross-linked polyethylene (HXLPE) bearing provided promising results with reduced wear and low prevalence of osteolysis in midterm studies. However, further studies with long-term follow-up are warranted.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Saito S, Saito M, Nishina T, Ohzono K, Ono K. Long-term results of total hip arthroplasty for osteonecrosis of the femoral head. A comparison with osteoarthritis. Clin Orthop Relat Res. 1989;(244):198–207.

    Google Scholar 

  2. Berry DJ, Harmsen WS, Cabanela ME, Morrey BF. Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am. 2002;84-A:171–7.

    Article  Google Scholar 

  3. Mont MA, Hungerford DS. Non-traumatic avascular necrosis of the femoral head. J Bone Joint Surg Am. 1995;77:459–74.

    Article  CAS  PubMed  Google Scholar 

  4. Kim YH, Oh JH, Oh SH. Cementless total hip arthroplasty in patients with osteonecrosis of the femoral head. Clin Orthop Relat Res. 1995;(320):73–84.

    Google Scholar 

  5. Hernigou P, Beaujean F. Abnormalities in the bone marrow of the iliac crest in patients who have osteonecrosis secondary to corticosteroid therapy or alcohol abuse. J Bone Joint Surg Am. 1997;79:1047–53.

    Article  CAS  PubMed  Google Scholar 

  6. Hernigou P, Beaujean F, Lambotte JC. Decrease in the mesenchymal stem-cell pool in the proximal femur in corticosteroid-induced osteonecrosis. J Bone Joint Surg Br. 1999;81:349–55.

    Article  CAS  PubMed  Google Scholar 

  7. Lee JS, Lee JS, Roh HL, Kim CH, Jung JS, Suh KT. Alterations in the differentiation ability of mesenchymal stem cells in patients with nontraumatic osteonecrosis of the femoral head: comparative analysis according to the risk factor. J Orthop Res. 2006;24:604–9.

    Article  PubMed  Google Scholar 

  8. Gangji V, Hauzeur JP, Schoutens A, Hinsenkamp M, Appelboom T, Egrise D. Abnormalities in the replicative capacity of osteoblastic cells in the proximal femur of patients with osteonecrosis of the femoral head. J Rheumatol. 2003;30:348–51.

    PubMed  Google Scholar 

  9. Tian L, Baek SH, Jang J, Kim SY. Imbalanced bone turnover markers and low bone mineral density in patients with osteonecrosis of the femoral head. Int Orthop. 2018;42:1545–9.

    Article  PubMed  Google Scholar 

  10. Kim YH, Kim JS. Histologic analysis of acetabular and proximal femoral bone in patients with osteonecrosis of the femoral head. J Bone Joint Surg Am. 2004;86-A:2471–4.

    Article  Google Scholar 

  11. Yoo JJ, Song WS, Koo KH, Yoon KS, Kim HJ. Osteogenic abilities of bone marrow stromal cells are not defective in patients with osteonecrosis. Int Orthop. 2009;33:867–72.

    Article  PubMed  Google Scholar 

  12. Tingart M, Beckmann J, Opolka A, Matsuura M, Schaumburger J, Grifka J, Grassel S. Analysis of bone matrix composition and trabecular microarchitecture of the femoral metaphysis in patients with osteonecrosis of the femoral head. J Orthop Res. 2009;27:1175–81.

    Article  PubMed  Google Scholar 

  13. Calder JD, Pearse MF, Revell PA. The extent of osteocyte death in the proximal femur of patients with osteonecrosis of the femoral head. J Bone Joint Surg Br. 2001;83:419–22.

    Article  CAS  PubMed  Google Scholar 

  14. Chiu KH, Shen WY, Ko CK, Chan KM. Osteonecrosis of the femoral head treated with cementless total hip arthroplasty. A comparison with other diagnoses. J Arthroplast. 1997;12:683–8.

    Article  CAS  Google Scholar 

  15. Ortiguera CJ, Pulliam IT, Cabanela ME. Total hip arthroplasty for osteonecrosis: matched-pair analysis of 188 hips with long-term follow-up. J Arthroplast. 1999;14:21–8.

    Article  CAS  Google Scholar 

  16. Cornell CN, Salvati EA, Pellicci PM. Long-term follow-up of total hip replacement in patients with osteonecrosis. Orthop Clin North Am. 1985;16:757–69.

    CAS  PubMed  Google Scholar 

  17. Salvati EA, Cornell CN. Long-term follow-up of total hip replacement in patients with avascular necrosis. Instr Course Lect. 1988;37:67–73.

    CAS  PubMed  Google Scholar 

  18. Piston RW, Engh CA, De Carvalho PI, Suthers K. Osteonecrosis of the femoral head treated with total hip arthroplasty without cement. J Bone Joint Surg Am. 1994;76:202–14.

    Article  CAS  PubMed  Google Scholar 

  19. Stulberg BN, Singer R, Goldner J, Stulberg J. Uncemented total hip arthroplasty in osteonecrosis: a 2- to 10-year evaluation. Clin Orthop Relat Res. 1997;(334):116–23.

    Google Scholar 

  20. Brinker MR, Rosenberg AG, Kull L, Galante JO. Primary total hip arthroplasty using noncemented porous-coated femoral components in patients with osteonecrosis of the femoral head. J Arthroplast. 1994;9:457–68.

    Article  CAS  Google Scholar 

  21. Fye MA, Huo MH, Zatorski LE, Keggi KJ. Total hip arthroplasty performed without cement in patients with femoral head osteonecrosis who are less than 50 years old. J Arthroplast. 1998;13:876–81.

    Article  CAS  Google Scholar 

  22. Kim YG, Kim SY, Park BC, Kim PT, Ihn JC, Kim ID. Uncemented Harris-Galante total hip arthroplasty in patients with osteonecrosis of the femoral head. A 10-16-year follow-up study. Acta Orthop. 2005;76:42–8.

    Article  PubMed  Google Scholar 

  23. Xenakis TA, Beris AE, Malizos KK, Koukoubis T, Gelalis J, Soucacos PN. Total hip arthroplasty for avascular necrosis and degenerative osteoarthritis of the hip. Clin Orthop Relat Res. 1997;(341):62–8.

    Google Scholar 

  24. Johannson HR, Zywiel MG, Marker DR, Jones LC, McGrath MS, Mont MA. Osteonecrosis is not a predictor of poor outcomes in primary total hip arthroplasty: a systematic literature review. Int Orthop. 2011;35:465–73.

    Article  PubMed  Google Scholar 

  25. Issa K, Naziri Q, Maheshwari AV, Rasquinha VJ, Delanois RE, Mont MA. Excellent results and minimal complications of total hip arthroplasty in sickle cell hemoglobinopathy at mid-term follow-up using cementless prosthetic components. J Arthroplast. 2013;28:1693–8.

    Article  Google Scholar 

  26. Ha YC, Kim HJ, Kim SY, Kim TY, Koo KH. THA using an anatomic stem in patients with femoral head osteonecrosis. Clin Orthop Relat Res. 2008;466:1141–7.

    Article  PubMed  PubMed Central  Google Scholar 

  27. Kim YH, Kim JS, Park JW, Joo JH. Contemporary total hip arthroplasty with and without cement in patients with osteonecrosis of the femoral head: a concise follow-up, at an average of seventeen years, of a previous report. J Bone Joint Surg Am. 2011;93:1806–10.

    Article  PubMed  Google Scholar 

  28. Min BW, Song KS, Bae KC, Cho CH, Lee KJ, Kim HJ. Second-generation cementless total hip arthroplasty in patients with osteonecrosis of the femoral head. J Arthroplast. 2008;23:902–10.

    Article  Google Scholar 

  29. Baek SH, Kim SY. Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis. J Bone Joint Surg Am. 2008;90:1314–20.

    Article  PubMed  Google Scholar 

  30. Baek SH, Kim WK, Kim JY, Kim SY. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA? Clin Orthop Relat Res. 2015;473:3796–802.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY. Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg Am. 2004;86-A:2475–81.

    Article  Google Scholar 

  32. Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am. 2003;85-A:2168–73.

    Article  Google Scholar 

  33. Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005;87:28–36.

    Article  PubMed  Google Scholar 

  34. Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH. Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res. 2007;458:106–10.

    Article  PubMed  Google Scholar 

  35. Howard DP, Wall PDH, Fernandez MA, Parsons H, Howard PW. Ceramic-on-ceramic bearing fractures in total hip arthroplasty: an analysis of data from the National Joint Registry. Bone Joint J. 2017;99-B:1012–9.

    Article  CAS  PubMed  Google Scholar 

  36. Walter WL, Waters TS, Gillies M, Donohoo S, Kurtz SM, Ranawat AS, Hozack WJ, Tuke MA. Squeaking hips. J Bone Joint Surg Am. 2008;90(Suppl 4):102–11.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Lee YK, Yoo JJ, Koo KH, Yoon KS, Kim HJ. Metal neck and liner impingement in ceramic bearing total hip arthroplasty. J Orthop Res. 2011;29:218–22.

    Article  PubMed  Google Scholar 

  38. Baek SH, Kim JY, Han JW, Kim SY. Potential risk of AMC ceramic liner for dissociation after square seating. J Orthop Sci. 2018;23:600–3.

    Article  PubMed  Google Scholar 

  39. Kurtz SM, Gawel HA, Patel JD. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res. 2011;469:2262–77.

    Article  PubMed  PubMed Central  Google Scholar 

  40. Campbell P, Shen FW, McKellop H. Biologic and tribologic considerations of alternative bearing surfaces. Clin Orthop Relat Res. 2004;(418):98–111.

    Google Scholar 

  41. Kurtz SM, Muratoglu OK, Evans M, Edidin AA. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials. 1999;20:1659–88.

    Article  CAS  PubMed  Google Scholar 

  42. Sakoda H, Voice AM, McEwen HM, Isaac GH, Hardaker C, Wroblewski BM, Fisher J. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. J Arthroplast. 2001;16:1018–23.

    Article  CAS  Google Scholar 

  43. Rohrl SM, Li MG, Nilsson KG, Nivbrant B. Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop. 2007;78:739–45.

    Article  PubMed  Google Scholar 

  44. Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am. 2007;89:2212–7.

    Article  PubMed  Google Scholar 

  45. Furmanski J, Kraay MJ, Rimnac CM. Crack initiation in retrieved cross-linked highly cross-linked ultrahigh-molecular-weight polyethylene acetabular liners: an investigation of 9 cases. J Arthroplast. 2011;26:796–801.

    Article  Google Scholar 

  46. Kim YH, Choi Y, Kim JS. Cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearing in young patients with femoral head osteonecrosis. J Arthroplast. 2011;26:218–23.

    Article  CAS  Google Scholar 

  47. Mall NA, Nunley RM, Zhu JJ, Maloney WJ, Barrack RL, Clohisy JC. The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene. Clin Orthop Relat Res. 2011;469:372–81.

    Article  PubMed  Google Scholar 

  48. Lachiewicz PF, Soileau ES, Martell JM. Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size. Clin Orthop Relat Res. 2016;474:365–71.

    Article  PubMed  Google Scholar 

  49. Lee JH, Lee BW, Lee BJ, Kim SY. Midterm results of primary total hip arthroplasty using highly cross-linked polyethylene: minimum 7-year follow-up study. J Arthroplast. 2011;26:1014–9.

    Article  Google Scholar 

  50. Min BW, Lee KJ, Song KS, Bae KC, Cho CH. Highly cross-linked polyethylene in total hip arthroplasty for osteonecrosis of the femoral head: a minimum 5-year follow-up study. J Arthroplast. 2013;28:526–30.

    Article  Google Scholar 

  51. Babovic N, Trousdale RT. Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up. J Arthroplast. 2013;28:815–7.

    Article  Google Scholar 

  52. Bedard NA, Callaghan JJ, Stefl MD, Willman TJ, Liu SS, Goetz DD. Fixation and wear with a contemporary acetabular component and cross-linked polyethylene at minimum 10-year follow-up. J Arthroplast. 2014;29:1961–9.

    Article  Google Scholar 

  53. Bragdon CR, Doerner M, Martell J, Jarrett B, Palm H, Multicenter Study Group, Malchau H. The 2012 John Charnley Award: clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA. Clin Orthop Relat Res. 2013;471:393–402.

    Article  PubMed  Google Scholar 

  54. Engh CA Jr, Hopper RH Jr, Huynh C, Ho H, Sritulanondha S, Engh CA Sr. A prospective, randomized study of cross-linked and non-cross-linked polyethylene for total hip arthroplasty at 10-year follow-up. J Arthroplast. 2012;27:2–7.e1.

    Article  Google Scholar 

  55. Garcia-Rey E, Garcia-Cimbrelo E, Cruz-Pardos A. New polyethylenes in total hip replacement: a ten- to 12-year follow-up study. Bone Joint J. 2013;95-B:326–32.

    Article  CAS  PubMed  Google Scholar 

  56. Greiner JJ, Callaghan JJ, Bedard NA, Liu SS, Gao Y, Goetz DD. Fixation and wear with contemporary acetabular components and cross-linked polyethylene at 10-years in patients aged 50 and under. J Arthroplast. 2015;30:1577–85.

    Article  Google Scholar 

  57. Johanson PE, Digas G, Herberts P, Thanner J, Karrholm J. Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study. Clin Orthop Relat Res. 2012;470:3083–93.

    Article  PubMed  PubMed Central  Google Scholar 

  58. Snir N, Kaye ID, Klifto CS, Hamula MJ, Wolfson TS, Schwarzkopf R, Jaffe FF. 10-year follow-up wear analysis of first-generation highly crosslinked polyethylene in primary total hip arthroplasty. J Arthroplast. 2014;29:630–3.

    Article  Google Scholar 

  59. Stambough JB, Pashos G, Bohnenkamp FC, Maloney WJ, Martell JM, Clohisy JC. Long-term results of total hip arthroplasty with 28-millimeter cobalt-chromium femoral heads on highly cross-linked polyethylene in patients 50 years and less. J Arthroplast. 2016;31:162–7.

    Article  Google Scholar 

  60. Nebergall AK, Greene ME, Laursen MB, Nielsen PT, Malchau H, Troelsen A. Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis. Bone Joint J. 2017;99-B:577–84.

    Article  CAS  PubMed  Google Scholar 

  61. Takada R, Jinno T, Koga D, Miyatake K, Muneta T, Okawa A. Comparison of wear rate and osteolysis between second-generation annealed and first-generation remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at a minimum of five years. Orthop Traumatol Surg Res. 2017;103:537–41.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shin-Yoon Kim .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2021 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Baek, SH., Kim, SY. (2021). Highly Cross-Linked Polyethylene Bearing. In: Drescher, W.R., Koo, KH., Windsor, R.E. (eds) Advances in Specialist Hip Surgery . Springer, Cham. https://doi.org/10.1007/978-3-030-61830-8_14

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-61830-8_14

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-61829-2

  • Online ISBN: 978-3-030-61830-8

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics