A Self-calibration Method for Mobile Manipulator

  • Hangbo Zou
  • Yinghao Li
  • Sijun Zhu
  • Kanfeng Gu
  • Xinggang Zhang
  • Mingyang ZhaoEmail author
Conference paper
Part of the Lecture Notes in Computer Science book series (LNCS, volume 11740)

Abstract

With the development of the mobile manipulator, it is needed to have a calibration method suits for ordinary people to improve its absolute position accuracy of the manipulator when the structure is worn. The method should be cheap, convinence and should do not rely on any professional equipment or external measurement. This paper proposes a self-calibration method that not only inherits the above advantages, but also is not affected by the convected motion caused by the shifting of the mobile platform. The basic idea is that when the endpoint of the manipulator reaches the specified target point in different configurations, if the gravity moment of the manipulator with respect to the platform remains basically unchanged, the shift of the platform and the influence of the convected motion can be neglected. By discretizing the target points in Cartesian space, grouping the data based on these target points, and combining the nonlinear least squares method, the parameters of the kinematic model can be optimized. Finally, the effectiveness of the proposed method is verified by different methods including the use of the laser tracker. The absolute position error of the flange center at the end of the manipulator is reduced from 2.25 mm to 0.42 mm.

Keywords

Mobile manipulator Self-calibration Absolute position accuracy 

Notes

Acknowledgments

This work is supported by the Special Research Foundation of Civil Aircraft of Ministry of Industry and Information Technology of China (No. MJ-2017-G-58) and the High-tech Industrialization Special Fund Project for Science and Technology Cooperation of Jilin Province and Chinese Academy of Sciences (No. 20170925006).

References

  1. 1.
    Birbach, O., Frese, U., Bäuml, B.: Rapid calibration of a multi-sensorial humanoid’s upper body: an automatic and self-contained approach. Int. J. Robot. Res. 34(4–5), 420–436 (2015)CrossRefGoogle Scholar
  2. 2.
    Chen, T.L., et al.: Robots for humanity: using assistive robotics to empower people with disabilities. IEEE Robot. Autom. Mag. 20(1), 30–39 (2013)CrossRefGoogle Scholar
  3. 3.
    Gaudreault, M., Joubair, A., Bonev, I.: Self-calibration of an industrial robot using a novel affordable 3D measuring device. Sensors 18(10), 3380 (2018)CrossRefGoogle Scholar
  4. 4.
    Hartenberg, R.S., Denavit, J.: A kinematic notation for lower pair mechanisms based on matrices. J. Appl. Mech. 77(2), 215–221 (1955)MathSciNetzbMATHGoogle Scholar
  5. 5.
    Hayati, S.A.: Robot arm geometric link parameter estimation. In: The 22nd IEEE Conference on Decision and Control, pp. 1477–1483. IEEE (1983)Google Scholar
  6. 6.
    He, R., Zhao, Y., Yang, S., Yang, S.: Kinematic-parameter identification for serial-robot calibration based on poe formula. IEEE Transact. Robot. 26(3), 411–423 (2010)CrossRefGoogle Scholar
  7. 7.
    Hollerbach, J., Khalil, W., Gautier, M.: Model identification. In: Siciliano, B., Khatib, O. (eds.) Springer Handbook of Robotics. Springer, Heidelberg (2008).  https://doi.org/10.1007/978-3-540-30301-5_15CrossRefGoogle Scholar
  8. 8.
    Khokar, K., Alqasemi, R., Sarkar, S., Reed, K., Dubey, R.: A novel telerobotic method for human-in-the-loop assisted grasping based on intention recognition. In: 2014 IEEE International Conference on Robotics and Automation (ICRA), pp. 4762–4769. IEEE (2014)Google Scholar
  9. 9.
    Santolaria, J., Aguilar, J.J., Yagüe, J.A., Pastor, J.: Kinematic parameter estimation technique for calibration and repeatability improvement of articulated arm coordinate measuring machines. Precis. Eng. 32(4), 251–268 (2008)CrossRefGoogle Scholar
  10. 10.
    Santolaria, J., Conte, J., Ginés, M.: Laser tracker-based kinematic parameter calibration of industrial robots by improved CPA method and active retroreflector. Int. J. Adv. Manuf. Technol. 66(9–12), 2087–2106 (2013)CrossRefGoogle Scholar
  11. 11.
    Stepanova, K., Pajdla, T., Hoffmann, M.: Robot self-calibration using multiple kinematic chainsa simulation study on the ICub humanoid robot. IEEE Robot. Autom. Lett. 4(2), 1900–1907 (2019)CrossRefGoogle Scholar
  12. 12.
    Zhang, X., Zheng, Z., Qi, Y.: Parameter identification and calibration of DH model for 6-DOF serial robots. Robot 38(3), 360–370 (2016)Google Scholar
  13. 13.
    Zhuang, H., Motaghedi, S.H., Roth, Z.S.: Robot calibration with planar constraints. In: Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No. 99CH36288C), vol. 1, pp. 805–810. IEEE (1999)Google Scholar

Copyright information

© Springer Nature Switzerland AG 2019

Authors and Affiliations

  • Hangbo Zou
    • 1
    • 2
    • 3
    • 4
  • Yinghao Li
    • 1
    • 2
    • 3
    • 4
  • Sijun Zhu
    • 1
    • 4
  • Kanfeng Gu
    • 1
    • 4
  • Xinggang Zhang
    • 1
    • 2
    • 3
    • 4
  • Mingyang Zhao
    • 1
    • 4
    Email author
  1. 1.Shenyang Institute of AutomationChinese Academy of SciencesShenyangChina
  2. 2.Institutes for Robotics and Intelligent ManufacturingChinese Academy of SciencesShenyangChina
  3. 3.University of Chinese Academy of SciencesBeijingChina
  4. 4.Kunshan Intelligent Equipment Research InstituteShenyang Institute of AutomatioKunshanChina

Personalised recommendations