Skip to main content
  • 125 Accesses

Abstract

It is known that the behavior of electromagnetic field probes is limited by the averaging of the measured fields over the finite size of the probe. This is the major restriction on the size of dipoles used in a very small array as an electric field probe. The two major requirements of an EM-field strength meter are:

  1. 1.

    The type of measured quantity

  2. 2.

    Accuracy of measurements

The first case should be determined by biologists and medical experts carrying out studies in the biological effects of hazardous EM fields. The exact specifications of this case have not yet been determined. This has led to the necessity of constructing a general purpose electromagnetic flux (mW/cm2) instrument. The second is an engineering problem; the accuracy should be maintained during measurement of any field irrespective of its configuration and in the presence of primary and secondary sources of radiation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Babij, T.M., Trzaska, H.: The Problem of Measurements of Electromagnetic Field Strength of Nonionizing Radiation. XVII Conf. Gen. URSI, Warsaw, Poland, 1972.

    Google Scholar 

  2. Bowman, R.R., Larson, E.B., Belsher, D.R.: Semiannual Progress Report: Electromagnetic Hazards Project, NBS Technical Note 9761, p. 31, 1969.

    Google Scholar 

  3. Guy, A.W.: Analysis of Electromagnetic Fields Induced in Biological Tissues by Thermographic Studies on Equivalent Phantom Models. IEEE Trans, vol. MTT-19, No. 2, 1971.

    Google Scholar 

  4. Kucia, H.R.: Accuracy Limitation in Measurements of HF Field Intensities for Protection Against Radiation Hazards. IEEE Trans., vol. IM-21, 1972.

    Google Scholar 

  5. Michaelson, S.M.: Human Exposure to Nonionizing Radiant Energy-Potential Hazards and Safety Standards. Proc. IEEE, vol. 60, No. 2, 1972.

    Google Scholar 

  6. Puntenney, D.G., Vetter, R.J., Weeks, W.L., Ziemer, P., Born, G.S.: Microwave Dosimetry Using Electrochemical Effects. The Journal of Microwave Power, vol. 9, 1974.

    Google Scholar 

  7. Rudge, A.W., Knox, R.M.: Near Field Instrumentation. Bureau of Radiological Health. BRH/DEP 70-16, 1970.

    Google Scholar 

  8. Schwan, H.P.: Microwave Radiation: Biophysical Considerations and Standards Criteria. IEEE Trans., vol. BME-19, May 1972.

    Google Scholar 

  9. Wacker, P.F., Bowman, R.R.: Quantifying Hazardous Electromagnetic Fields: Scientific Basis and Practical Considerations. IEEE Trans., vol. MTT-19, 1972.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1975 Plenum Press, New York

About this chapter

Cite this chapter

Babij, T.M. (1975). Synthesis of Frequency Response of Electric Field Probes. In: Michaelson, S.M., Miller, M.W., Magin, R., Carstensen, E.L. (eds) Fundamental and Applied Aspects of Nonionizing Radiation. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-0760-0_3

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-0760-0_3

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-0762-4

  • Online ISBN: 978-1-4684-0760-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics