Skip to main content

The Attenuation Effect in Pulsed Doppler Flowmeters

  • Chapter
Acoustical Imaging

Part of the book series: Acoustical Imaging ((ACIM,volume 21))

  • 411 Accesses

Abstract

Pulsed Doppler flowmeters are considered to estimate the velocity of blood flow by measuring the frequency shift of echoes, due to the Doppler effect1. Typical frequency shifts of the echoes are of the order of kHz. However, the time and frequency domain properties of ultrasound pulses travelling in tissue also undergo changes due to propagating and scattering effects. For example, the attenuation coefficient for a soft tissue such as liver 2 is α.(f) = 0.4f 1.14. If the emitted pulse is assumed to be Gaussian, with a centre frequency of 5 MHz and a 3 dB bandwidth of 0.8 MHz, the shift in mean frequency with depth for such a medium is calculated to be 0.11 MHz cm-1 . Hence, if pulsed Doppler flowmeters assess velocity by estimating a shift in frequency of the echoes, then attenuation should have a dramatic influence on the measurement outcome. Such a severe effect is not seen 1,3,4 and, although several investigators have considered the influence of attenuation, no clear reason for this discrepancy has been proposed and there is disagreement as to the size of the effect.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Azimi M. And Kak A. C., 1985 - An Analytical Study of Doppler Ultrasound Systems. Ultrasonic Imaging, 7, pp. 1–48.

    Article  Google Scholar 

  2. Lin T. and Ophir J., 1987 - Frequency-Dependent Ultrasonic Differentiation of Normal and Diffusely Diseased Liver, J. Acoust. Soc. Am., vol. 64, pp. 423–457.

    Google Scholar 

  3. Holland S. K., Orphanoudakis S. C. and Jaffe C. C., 1984 - Frequency- dependent attenuation effects in pulsed Doppler ultrasound: experimental results, IEEE Trans. Biomed. Eng., vol. BME-31, pp. 626–631.

    Article  Google Scholar 

  4. Thomas N. and Leeman S., 1991 - Blood Velocity Estimation in Medical Imaging - Artefacts and Errors, in: “Ultrasonics International ’91” (Butterworth, Guildford), pp. 95–98.

    Google Scholar 

  5. Leeman S., Roberts V.C. and Willson K., 1986 - Quantitative Doppler with ultrasound pulses. In: “Physics in Medical Ultrasound”, J.A. Evans, ed., IPSM, London, pp. 134–140.

    Google Scholar 

  6. Atkinson P. and Woodcock J. P., 1982 - Doppler Ultrasound and its use in Clinical Measurement. (Academic Press: London).

    Google Scholar 

  7. Advanced Technology Laboratories, February 20th 1984 - Service Manual for 459 Series Pulsed Doppler/Flow Analyzer, Adaptive Doppler, P/N 106–23155–02, Rev B, 4, pp. 14.

    Google Scholar 

  8. Oppenheim A. V., Willsky A. S. with Young I. T., 1983 - Sampling, Chapter 8. In: Signals and Systems, Prentice-Hall.

    Google Scholar 

  9. Thomas N. and Leeman S., 1991 - Mean Frequency Via Zero Crossings, IEEE Ultrasonics Symposium Proceedings, pp. 1297–1300.

    Google Scholar 

  10. Foster S. G., Embree P. M. and O’Brien W. D., 1990 - Flow Velocity Profile via Time-Domain Correlation: Error Analysis and Computer Simulation. IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 37, No 2, pp. 164–175.

    Article  Google Scholar 

  11. Thomas N. and Leeman S., 1993 - The Double Doppler Effect, International Conference on Acoustical Sensing and Imaging, Publ. No. 369, (IEE: London), pp. 164–168.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 Springer Science+Business Media New York

About this chapter

Cite this chapter

Thomas, N., Leeman, S. (1995). The Attenuation Effect in Pulsed Doppler Flowmeters. In: Jones, J.P. (eds) Acoustical Imaging. Acoustical Imaging, vol 21. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-1943-0_58

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-1943-0_58

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-5797-1

  • Online ISBN: 978-1-4615-1943-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics