Skip to main content

A Miniature MRI-Compatible Fiber-optic Force Sensor Utilizing Fabry-Perot Interferometer

  • Conference paper
  • First Online:
MEMS and Nanotechnology, Volume 4

Abstract

Magnetic resonance imaging provides superior imaging capability because of unmatched soft tissue contrast and inherent three-dimensional visualization. Force sensing in robot-assisted systems is crucial for providing tactile feedback and measuring tissue interaction forces in needle-based percutaneous procedures in MRI. To address the issues imposed by electromagnetic compatibility in the high-field MRI and mechanical constraints due to the confined close-bore space, this paper proposes a miniaturized fiber optic force sensor utilizing Fabry-Perot interferometry. An opto-electromechanical system is designed to experimentally validate the optical model of the sensor and evaluate its sensing capability. Calibration was performed under static and dynamics loading conditions. The experimental results indicate a gage sensitivity on the order of 40 (mV/με) of the sensor and a sensing range of 10 Newton. This sensor achieves high-resolution needle insertion force sensing in a robust and compact configuration in MRI environment.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. D’Amico A. V., Cormack R. A. and Tempany C. M., “MRI-guided diagnosis and treatment of prostate cancer”. New England Journal of Medicine, volume 344(10), pp. 776-7, 2001.

    Article  Google Scholar 

  2. Polygerinos P., Puangmali P., Schaeffter T., Razavi R., Seneviratne L., and Althoefer K., “Novel miniature MRIcompatible fiber-optic force sensor for cardiac catheterization procedures,” in Robotics and Automation (ICRA), 2010 IEEE International Conference on, pp. 2598–2603, May 2010.

    Google Scholar 

  3. Su H. and G. Fischer, “A 3-axis optical force/torque sensor for prostate needle placement in magnetic resonance imaging environments,” 2nd Annual IEEE International Conference on Technologies for Practical Robot Applications, (Boston, MA, USA), pp. 5–9, IEEE, 2009.

    Google Scholar 

  4. Park Y.-L., Elayaperumal S., Ryu S., Daniel B., Black R. J., Moslehi B., and Cutkosky M., “MRI-compatible Haptics: Strain sensing for real-time estimation of three dimensional needle deflection in MRI environments,” in International Society for Magnetic Resonance in Medicine (ISMRM), 17th Scientific Meeting and Exhibition, (Honolulu, Hawaii), 2009.

    Google Scholar 

  5. Su H. and Fischer G. S., “High-field MRI-Compatible needle placement robots for prostate interventions: pneumatic and piezoelectric approaches,” in Advances in Robotics and Virtual Reality (T. Gulrez and A. Hassanien, eds.), Springer- Verlag, 2011.

    Google Scholar 

  6. Huang H., Su H. and, Mills J., “Force Sensing and Control of Robot-Assisted Cell Injection”, eds. T. Gulrez and A. Hassanien, Advances in Robotics and Virtual Reality, Springer-Verlag, 2011

    Google Scholar 

  7. Wang Y., Cole G., Su H., Pilitsis J., and Fischer G., “MRI compatibility evaluation of a piezoelectric actuator system for a neural interventional robot,” in Annual Conference of IEEE Engineering in Medicine and Biology Society, (Minneapolis, MN), pp. 6072–6075, 2009.

    Google Scholar 

  8. Cole G., Harrington K., Su H., Camilo A., Pilitsis J., and Fischer G.S., “Closed-Loop Actuated Surgical System Utilizing Real-Time In-Situ MRI Guidance,” in 12th International Symposium on Experimental Robotics - ISER 2010, (New Delhi and Agra, India), Dec 2010.

    Google Scholar 

  9. Wang Y., Su H., Harrington K., and Fischer G. S., “Sliding mode Control of piezoelectric valve regulated pneumatic actuator for MRI-compatible robotic intervention,” in ASME Dynamic Systems and Control Conference - DSCC 2010, (Cambridge, MA, USA), 2010.

    Google Scholar 

  10. Su H., Camilo A., Cole G., Tempany C.M., Hata N. and Fischer G. S., “ High-Field MRI Compatible Steerable Needle Driver Robot for Percutaneous Prostate Intervention”, Proceedings of MMVR18 (Medicine Meets Virtual Reality), Newport Beach, California, USA, February, 2011

    Google Scholar 

  11. Lemay J., White F., Zervas M., “Evaluation and Application of a High Resolution Fiber-Optic Strain Sensor”, Major Qualifying Project, Dept. of Mechanical Engineering, Worcester Polytechnic Institute, April. 2010.

    Google Scholar 

  12. Gangopadhyay T. K., “Prospects for fiber Bragg gratings and Fabry-Perot interferometers in fiber-optic vibration sensing,” Sensors and Actuators A: Physical, vol. 113, no. 1, pp. 20 – 38, 2004.

    Article  Google Scholar 

  13. RocTest Limited, FISO Technologies, Inc., Sensoptic Fiber-Optic Strain Sensors - Fabry-Perot Strain Gage – FOS Series. Quebec, Canada: RocTest, 2000

    Google Scholar 

  14. ANSYS, “ANSYS Academic Teaching Mechanical,” Accessed 15 February 2010

    Google Scholar 

  15. National Instruments. Retrieved April 12, 2010, from http://www.ni.com

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hao Su .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer Science+Business Media, LLC

About this paper

Cite this paper

Su, H., Zervas, M., Furlong, C., Fischer, G.S. (2011). A Miniature MRI-Compatible Fiber-optic Force Sensor Utilizing Fabry-Perot Interferometer. In: Proulx, T. (eds) MEMS and Nanotechnology, Volume 4. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-0210-7_19

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-0210-7_19

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-0209-1

  • Online ISBN: 978-1-4614-0210-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics