Abstract
This chapter is focused on the development and use of acoustic wave biosensor platforms for the detection of bacteria, specifically those based on the thickness shear mode (TSM) resonator. We demonstrated the mechanical and electrical implications of bacterial positioning at the solid-liquid interface of a TSM biosensor and presented a model of the TSM with bacteria attached operating as coupled oscillators. The experiments and model provide an understanding of the nature of the signals produced by acoustic wave devices when they are used for testing bacteria. The paradox of “negative mass” could be a real threat to the interpretation of experimental results related to the detection of bacteria. The knowledge of the true nature of “negative mass” linked to the strength of bacteria attachment will contribute significantly to our understanding of the results of “weighing bacteria.” The results of this work can be used for bacterial detection and control of processes of bacterial settlement, bacterial colonization, biofilm formation, and bacterial infection in which bacterial attachment plays a role.
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Aberl F and Wolf H (1993) Present trends in immunosensors. LaborPraxis 70–74, 76–77
Ahluwalia A, Derossi D, Ristori C, Schirone A and Serra G (1992) A comparative study of protein immobilization techniques for optical immunosensors. Biosens. Bioelectron. 7:207–214
Ahmad A and Ahmad S (1996) Solvent effect on antibody antigen interaction. Environ. Res. 5:29–36
Aisenbrey C, Harzer U, Bauer-Manz G, Bar G, Chotimah INH, Bertani P, Sizun C, Kuhn A and Bechinger B (2006) Proton-decoupled 15N and 31P solid-state NMR investigations of the Pf3 coat protein in oriented phospholipid bilayers. FEBS Journal 273:817–828
Aizawa H, Kurosawa S, Tanaka M, Yoshimoto M, Miyake J and Tanaka H (2001) Rapid diagnosis of Treponema pallidum in serum using latex piezoelectric immunoassay. Anal. Chim. Acta 437:167–169
Alberts B, Bray D, Lewis J, Raff M, Roberts K and Watson JD (1994) Molecular biology of the cell, 3rd ed. New York: Garland Publishing
Auner GW, Shreve G, Ying H, Newaz G, Hughes C and Xu J (2003) Dual-mode acoustic wave biosensors microarrays. Proc. SPIE Int. Soc. Opt. Eng. 5119:129–139
Babacan S, Pivarnik P, Letcher S., and Rand, A.G. 2000. Evaluation of antibody immobilization methods for piezoelectric biosensor application. Biosens. Bioelectron. 15:615–621
Babacan, S., Pivarnik, P, Letcher S and Rand AG (2002) Piezoelectric flow injector analysis biosensor for the detection of Salmonella typhimurium. J. Food Sci. 61: 314–320
Bailey CA, Fiebor B, Yen W, Vodyanoy V, Cernosek RW and Chin BA (2002) Thickness shear mode (TSM) resonators used for biosensing. Proc. SPIE Int. Soc. Opt. Eng. 4575:138–149
Balasubramanian S, Sorokulova IB, Vodyanoy VJ and Simonian AL (2007) Lytic phage as a specific and selective probe for detection of Staphylococcus aureus—A surface plasmon resonance spectroscopic study. Biosens. Bioelectron. 22:948–955
Ballantine DS, White RM, Martin SJ, Ricco AJ, Zellers ET, Frye GC, Wohltjen H, Levy M and Stern R (1997) Acoustic Wave Sensors: Theory, Design, & Physico-Chemical Applications. Academic Press, San Diego
Bandey HL, Martin SJ, Cernosek RW and Hillman AR (1999) Modeling the responses of thickness-shear mode resonators under various loading conditions. Anal. Chem. 71:2205–2214
Bao L, Deng L, Nie L, Yao S and Wei W (1996a) Determination of microorganisms with a quartz crystal microbalance sensor. Anal. Chim. Acta 319:97–101
Bao L, Deng L, Nie L, Yao S and Wei W (1996b) A rapid method for determination of Proteus vulgaris with a piezoelectric quartz crystal sensor coated with a thin liquid film. Biosens. Bioelectron. 11:1193–1198
Barraud A, Perrot H, Billard V, Martelet C and Therasse J (1993) Study of immunoglobulin G thin layers obtained by the Langmuir-Blodgett method: application to immunosensors. Biosens. Bioelectron. 8:39–48
Bashtovyy D, Marsh D, Hemminga MA and Pali T (2001) Constrained modeling of spin-labeled major coat protein mutants from M13 bacteriophage in a phospholipid bilayer. Protein Sci. 10:979–987
Ben-Dov I, Willner I and Zisman E (1997) Piezoelectric immunosensors for urine specimens of Chlamydia trachomatis employing quartz crystal microbalance microgravimetric analyses. Anal. Chem. 69:3506–3512
Berg S, Johannsmann D and Ruths M (2002) Frequency response of quartz crystal shear-resonator during an adhesive, elastic contact in a surface forces apparatus. J. Appl. Phys. 92:6905–6910
Berkenpas E, Millard P and Pereira da Cunha M (2006) Detection of Escherichia coli O157:H7 with langasite pure shear horizontal surface acoustic wave sensors. Biosens. Bioelectron. 21:2255–2262
Bessueille F, Dugas V, Vikulov V, Cloarec JP, Souteyrand E and Martin JR (2005) Assessment of porous silicon substrate for well-characterized sensitive DNA chip implement. Biosens. Bioelectron. 21: 908–916
Betageri GV, Black CD, Szebeni J, Wahl LM and Weinstein JN (1993) Fc-receptor-mediated targeting of antibody-bearing liposomes containing dideoxycytidine triphosphate to human monocyte/macrophages. J. Pharm. Pharamcol. 45:48–53
Borovskya B, Krim J, Syed Asif S and Wahl K (2001) Measuring nanomechanical properties of a dynamic contact using an indenter probe and quartz crystal microbalance. J. Appl. Phys. 90:6391–6396
Branch DW and Brozik SM (2004) Low-level detection of a Bacillus anthracis simulant using love-wave biosensors on 36ˆ YX LiTaO3. Biosens. Bioelectron. 19:849–859
Bunde RL, Jarvi EJ and Rosentreter JJ (1998) Piezoelectric quartz crystal biosensors. Talanta 46:1223–1236
Buzby JC and Roberts T (1997) Economic costs and trade impacts of microbial food-borne illness. World Health Stat. Q. 50:57–66
Bykov VA (1996) Langmuir-Blodgett films and nanotechnology. Biosens. Bioelectron. 11:923–932
Carter RM, Jacobs MB, Lubrano GJ and Guilbault GG (1995a) Piezoelectric detection of ricin and affinity-purified goat anti-ricin antibody. Anal. Lett. 28:1379–1386
Carter RM, Mekalanos JJ, Jacobs MB, Lubrano GJ and Guilbault GG (1995b) Quartz crystal microbalance detection of Vibrio cholerae O139 serotype. J. Immunol. Methods 187:121–125
Casalinuovo I, Di Pierro D, Bruno E, Di Francesco P and Coletta M (2005) Experimental use of a new surface acoustic wave sensor for the rapid identification of bacteria and yeasts. Lett. Appl. Microbiol. 42:24–29
Cavicacute BA, Hayward GL and Thompson M (1999) Acoustic waves and the study of biochemical macromolecules and cells at the sensor-liquid interface. Analyst 124:1405–1420
Chang K-S, Jang H-D, Lee C-F, Lee Y-G, Yuan C-J and Lee S-H (2006) Series quartz crystal sensor for remote bacteria population monitoring in raw milk via the Internet. Biosens. Bioelectron. 21:1581–1590
Chen M, Liu M, Yu L, Cai G, Chen Q, Wu R, Wang F, Zhang B, Jiang T and Fu W (2005) Construction of a novel peptide nucleic acid piezoelectric gene sensor microarray detection system. J. Nanosci. Nanotechnol. 5:1266–1272
Chin RC, Salazar N, Mayo MW, Villavicencio V, Taylor RB, Chambers JP and Valdes JJ (1996) Development of a bacteriophage displayed peptide library and biosensor. Proc. SPIE Int. Soc. Opt. Eng. 2680:16–26
Chothia C and Janin J (1975) Principles of protein-protein recognition. Nature 256:705–708
Chou PY and Fasman GD (1974) Prediction of protein conformation. Biochemistry 13:222–245
Clark LCJ and Lyons C (1962) Electrode systems for continuous monitoring in cardiovascular surgery. Ann. N. Y. Acad. Sci. 102:29–45
Cornell BA, Braach-Maksvytis VL, King LG, Osman PD, Raguse B, Wieczorek L and Pace RJ (1997) A biosensor that uses ion-channel switches. Nature 387:580–583
Cornell BA, Krishna G, Osman PD, Pace RD and Wieczorek L (2001) Tethered-bilayer lipid membranes as a support for membrane-active peptides. Biochem. Soc. Trans. 29:613–617
Curie J and Curie P (1880) Ann. de Chim. et Phys. 91:294
Dai J, Baker GL and Bruening ML (2006) Use of porous membranes modified with polyelectrolyte multilayers as substrates for protein arrays with low nonspecific adsorption. Anal. Chem. 78:135–140
Davies LT and Rideal EK (1963) Interfacial Phenomena. Academic Press, New York
Deisingh A and Thompson M (2001) Sequences of E. coli O157:H7 detected by a PCR-acoustic wave sensor combination. Analyst 126:2153–2158
Deng L, Tan, H, Xu Y, Nie L and Yao S (1997) On-line rapid detection of urease-producing bacteria with a novel bulk acoustic wave ammonia sensor. Enzyme Microb. Technol. 21:258–264
Deobagkar DD, Limaye V, Sinha S and Yadava RDS (2005) Acoustic wave immunosensing of Escherichia coli in water. Sens. Actuators B 104:85–89
Dickert F, Hayden O, Lieberzeit P, Palfinger C, Pickert D, Wolff U and Scholl G (2003) Borderline applications of QCM-devices: synthetic antibodies for analytes in both nm- and um-dimensions. Sens. Actuators B 95:20–24
Dickert FL, Hayden O, Bindeus R, Mann K, Blaas D and Waigmann E (2004) Bioimprinted QCM sensors for virus detection–screening of plant sap. Anal. Bioanal. Chem. 378:1929–1934
Dickert FL, Lieberzeit P and Hayden O (2003) Sensor strategies for microorganism detection–from physical principles to imprinting procedures. Anal. Bioanal. Chem. 377:540–549
Dybwad G (1985) A sensitive new method for the determination of adhesive bonding between a particle and a substrate. J. Appl. Phys. 58:2789–2790
Eun A, Huang L, Chew F, Li S and Wong S (2002) Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors. J. Virol. Methods 99:71–79
Fan H, Lu Y, Stump A, Reed ST, Baer T, Schunk R, Perez-Luna V, Lopez GP and Brinker CJ (2000) Rapid prototyping of patterned functional nanostructures. Nature 405:56–60
World Health Organization (1997) Foodborne diseases—possibly 350 times more frequent than reported. Need publication data here – also move this to correct alphabetical position in list.
Frisk T, Ronnholm D, van der Wijngaart W and Stemme G (2006) A micromachined interface for airborne sample-to-liquid transfer and its application in a biosensor system. Lab. Chip 6:1504–1509
Fung YS and Wong YY (2001) Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect Salmonella in aqueous solution. Anal. Chem. 73: 5302–5309
Furch M, Ueberfeld J, Hartmann A, Bock D and Seeger S (1996) Ultrathin oligonucleotide layers for fluorescence based DNA-sensors. Proc. SPIE Int. Soc. Opt. Eng. 2928:220–226
Gaines GLJ (1966) Insoluble Monolayers at Liquid-gas Interfaces. Interscience, New York
Gao H, Kislig E, Oranth N and Sigrist H (1994) Photolinker-polymer-mediated immobilization of monoclonal antibodies, F(ab’)2 and F(ab’) fragments. Biotechnol. Appl. Biochem. 20:251–263
Gao Z, Tao G and Li G (1998) Research on detection of type C2 staphylococcus enterotoxin in food with piezoelectric immunosensors. Wei Sheng Yan Jiu 27:122–124
Garnier J, Osguthorpe DJ and Robson B (1978) Analysis of the accuracy and implications of simple methods for predicting the secondary structure of globular proteins. J. Mol. Biol. 120:97–120
Gawrisch K, Gaede HC, Luckett KM, Polozov IV and Yeliseev A (2005) Solid-supported membranes inside porous substrates and their use in biosensors, WIPO Patent WO/2005/069004 http://www.wipo.int/pctdb/en/ia.jsp?IA=US2005/ 000069&LANGUAGE=EN (accessed April 11, 2007)
Ghafouri S and Thompson M (1999) Interfacial properties of biotin conjugate avidin complexes studied by acoustic wave sensor. Langmuir 15:564–572
Gizeli E (2002) Biomolecular Sensors. Taylor & Francis, Inc., New York, pp 176–206
Goldman ER, Pazirandeh MP, Charles PT, Balighian E.D and Anderson GP (2002) Selection of phage displayed peptides for the detection of 2,4,6-trinitrotoluene in seawater. Anal. Chim. Acta 457:13–19
Goldman ER, Pazirandeh MP, Mauro JM, King KD, Frey JC and Anderson GP (2000) Phage-displayed peptides as biosensor reagents. J. Mol. Recognit. 13:382–387
Goodchild S, Love T, Hopkins N and Mayers C (2006) Engineering antibodies for biosensor technologies. Adv. Appl. Microbiol. 58:185–226
Grate JW and Frye GC (1996) Acoustic wave sensors. Sens. Update 2:37–83
Griffith J, Manning M and Dunn K (1981) Filamentous bacteriophage contract into hollow spherical particles upon exposure to a chloroform-water interface. Cell 23:747–753
Harteveld JLN, Nieuwenhuizen MS and Wils ERJ (1997) Detection of staphylococcal enterotoxin B employing a piezoelectric crystal immunosensor. Biosens. Bioelectron. 12:661–667
Hayden O, Bindeus R and Dickert FL (2003) Combining atomic force microscope and quartz crystal microbalance studies for cell detection. Meas. Sci. Technol. 14: 1876–1881
Hayden O and Dickert FL (2001) Selective microorganism detection with cell surface imprinted polymers. Adv. Mater. 13:1480–1483
He F, Geng Q, Zhu W, Nie L, Yao S and Meifeng C (1994) Rapid detection of Escherichia coli using a separated electrode piezoelectric crystal sensor. Anal. Chim. Acta 289:313–319
He F and Zhang L (2002) Rapid diagnosis of M. tuberculosis using a piezoelectric immunosensor. Anal. Sci. 18:397–401
He F, Zhang X, Zhou J and Liu Z (2006) A new MSPQC system for rapid detection of pathogens in clinical samples. J. Microbiol. Methods 66:56–62
He F, Zhao J, Zhang L and Su X (2003) A rapid method for determining Mycobacterium tuberculosis based on a bulk acoustic wave impedance biosensor. Talanta 59:935–941
He F and Zhou J (2007) A new antimicrobial susceptibility testing method of Escherichia coli against ampicillin by MSPQC. J. Microbiol. Methods 68:563–567
Herriott RM and Barlow JL (1957) The protein coats or “ghosts” of Escherichia coli phage T2. Preparation, assay, and some chemical properties. J. Gen. Physiol. 40:809–825
Horisberger M (1984) Electron-opaque markers: a review. In: Polak JM and Varndell IM (eds) Immunolabelling for Electron Microscopy. Elsevier, Amsterdam
Horisberger M (1992) Colloidal gold and its application in cell biology. Int. Rev. Cytol. 136:227–87
Houbiers MC and Hemminga MA (2004) Protein-lipid interactions of bacteriophage M13 gene 9 minor coat protein. Mol. Membr. Biol. 21:351–359
Houbiers MC, Wolfs CJAM, Spruijt RB, Bollen YJM, Hemminga MA and Goormaghtigh E (2001) Conformation and orientation of the gene 9 minor coat protein of bacteriophage M13 in phospholipid bilayers. Biochim. Biophys. Acta Biomembr. 1511:224–235
Howe E and Harding G (2000) A comparison of protocols for the optimisation of detection of bacteria using a surface acoustic wave (SAW) biosensor. Biosens. Bioelectron. 15:641–649
Im W and Brooks CL (2004) De novo folding of membrane proteins: an exploration of the structure and NMR properties of the fd coat protein. J. Mol. Biol. 337:513–519
Ishimori Y, Karube I and Suzuki IS (1981) Determination of microbial populations with piezoelectric membranes. Appl. Environ. Microbiol. 42:632–637
Ivnitski D, Abdel-Hamid I, Atanasov P and Wilkins E (1999) Biosensors for detection of pathogenic bacteria. Biosens. Bioelectron. 14:599–624
Janshoff A, Galla HJ and Steinem C (2000) Piezoelectric mass-sensing devices as biosensors-an alternative to optical biosensors? Angew. Chem. Int. Ed. Engl. 39:4004–4032
Janshoff A and Steinem C (2001) Quartz crystal microbalance for bioanalytical applications. Sens. Update 9:313–354
Janshoff A, Steinem C and Wegener J (2004) Noninvasive Electrical Sensor Devices to Monitor Living Cells Online. Ultrathin Electrochemical Chemo- and Biosensors. Springer, New York
Jiang Y-B, Liu N, Gerung H, Cecchi JL and Brinker CJ (2006) Nanometer-thick conformal pore sealing of self-assembled mesoporous silica by plasma-assisted atomic layer deposition. J. Am. Chem. Soc. 128:11018–11019
Kaspar M, Stadler H, Weiss T and Ziegler C (2000) Thickness shear mode resonators (“mass sensitive devices”) in bioanalysis. Fresenius J. Anal. Chem. 366:602–610
Kim G-H, Rand AG and Letcher SV (2003) Impedance characterization of a piezoelectric immunosensor part II: Salmonella typhimurium detection using magnetic enhancement. Biosens. Bioelectron. 18:91–99
Kim N and Park I-S (2003) Application of a flow-type antibody sensor to the detection of Escherichia coli in various foods. Biosens. Bioelectron. 18:1101–1107
Kim N, Park I-S and Kim D-K (2004) Characteristics of a label-free piezoelectric immunosensor detecting Pseudomonas aeruginosa. Sens. Actuators B 100:432–438
King WH (1964) Piezoelectric sorption detector. Anal. Chem. 36:1735–1739
Kleinschmidt AK, Lang D, Jacherts D and Zahn RK (1962) Preparation and length measurements of the total deoxyribonucleic acid (DNA) content of T2 bacteriophages. Biochim. Biophys. Acta 61:875–864
Konig B and Gratzel M (1993) Detection of viruses and bacteria with piezoelectric immunosensors. Anal. Lett. 26:1567–1585
Konig B and Gratzel M (1995) A piezoelectric immunosensor for hepatitis viruses. Anal. Chim. Acta 309:19–25
Kouzmitcheva G (2005) Personal communication.
Krause R (1993) Process control for Ni/Au plating with QCM technology. Circuitree 6:10–12
Kreth J, Hagerman E, Tam K, Merritt J, Wong D, Wu B, Myung N, Shi W and Qi F (2004) Quantitative analyses of Streptococcus mutans biofilms with quartz crystal microbalance, microjet impingement and confocal microscopy. Biofilms 1:277–284
Kurosawa S, Park J, Aizawa H, Wakida S, Tao H and Ishihara K (2006) Quartz crystal microbalance immunosensors for environmental monitoring. Biosens. Bioelectron. 22:473–481
Lakshmanan RS, Hu J, Guntupalli R, Wan J, Huang S, Yang H, Petrenko VA, Barbaree JM and Chin BA (2006) Detection of Salmonella typhimurium using phage based magnetostrictive sensor. Proc. SPIE Int. Soc. Opt. Eng. 6218:62180Z
Lazcka O, Campo FJD and Munoz FX (2007) Pathogen detection: A perspective of traditional methods and biosensors. Biosens. Bioelectron. 22:1205–1217
Le D, He F-J, Jiang TJ, Nie L and Yao S (1995) A goat-anti-human IgG modified piezoimmunosensor for Staphylococcus aureus detection. J. Microbiol. Methods 23:229–234
Leonard P, Hearty S, Brennan J, Dunne L, Quinn J, Chakraborty T and O’Kennedy R (2003) Advances in biosensors for detection of pathogens in food and water. Enzyme Microb. Technol. 32:3–13
Lin H-C and Tsai W-C (2003) Piezoelectric crystal immunosensor for the detection of staphylococcal enterotoxin B. Biosens. Bioelectron. 18:1479–1483
Love AEH (1911) Some problems of geodynamics. Cambridge: Cambridge
Lucklum R (2005) Non-gravimetric contributions to QCR sensor response. Analyst 130:1465–1473
Mao X, Yang L, Su X-L and Li Y (2006) A nanoparticle amplification based quartz crystal microbalance DNA sensor for detection of Escherichia coli O157:H7. Biosens. Bioelectron. 21:1178–1185
Martin SJ, Granstaff VE and Frye GC (1991) Characterization of quartz crystal microbalance with simultaneous mass and liquid loading. Anal. Chem. 63:2272–2281
Marxer C, Coen M, Greber T, Greber U and Schlapbach L (2003) Cell spreading on quartz crystal microbalance elicits positive frequency shifts indicative of viscosity changes. Anal. Bioanal. Chem. 377:578–586
Mead P, Slutsker L, Dietz V, McCaig L, Bresee J, Shapiro C, Griffin P and Tauxe RV (1999) Food-related illness and death in the United States. Emerg. Infect. Dis. 5:607–625
Minunni M, Skladal P and Mascini M (1994) A piezoelectric quartz crystal biosensor as a direct affinity sensor. Anal. Lett. 27:1475–1487
Mittler-Neher S, Spinke J, Liley M, Nelles G, Weisser M, Back R, Wenz G and Knoll W (1995) Spectroscopic and surface-analytical characterization of self-assembled layers on Au. Biosens. Bioelectron. 10:903–916
Mo X-T, Zhou Y-P, Lei H and Deng L (2002) Microbalance-DNA probe method for the detection of specific bacteria in water. Enzyme Microb. Technol. 30:583–589
Moll N, Pascal E, Dinh DH, Pillot J-P, Bennetau B, Rebiere D, Moynet D, Mas Y, Mossalayi D, Pistre J and Dejous C (2007) A Love wave immunosensor for whole E. coli bacteria detection using an innovative two-step immobilisation approach. Biosens. Bioelectron. 22:2145–2150
Morgan DP (2000) A history of surface acoustic wave devices. Int. J. High Speed Electron. Syst. 10:553–602
Muramatsu H, Kajiwara K, Tamiya E, Karube I (1986) Piezoelectric immunosensor for the detection of Candida albicans microbes. Anal. Chim. Acta 188:257–261
Muratsugu M, Ohta F, Miya Y, Hosokawa T, Kurosawa S, Kamo N and Ikeda H (1993) Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: relationship between the frequency change and the mass of protein adsorbed. Anal. Chem. 65:2933–2937
Nakanishi K, Karube I, Hiroshi S, Uchida A and Ishida Y (1996) Detection of the red tide-causing plankton Chattonella marina using a piezoelectric immunosensor. Anal. Chim. Acta 325:73–80
Nanduri V (2005) Phage at the air-liquid interface for the fabrication of biosensors. Doctoral Dissertation. graduate.auburn.edu/auetd Auburn University, Alabama
Nanduri V, Sorokulova IB, Samoylov AM, Simonian AL, Petrenko VA, Vodyanoy V (2007) Phage as a molecular recognition element in biosensors immobilized by physical adsorption. Biosens. Bioelectron. 22:986–992
Neidhardt FC (1987) Escherichia coli and Salmonella. American Society For Microbiology, Washington, D.C.
Nishiyama Y, Tanaka S, Hillhouse HW, Nishiyama N, Egashira Y and Ueyama K (2006) Synthesis of ordered mesoporous zirconium phosphate films by spin coating and vapor treatments. Langmuir 22:9469–9472
Niven D, Chambers J, Anderson T and White D (1993) Long-term, on-line monitoring of microbial biofilms using a quartz crystal microbalance. Anal. Chem. 65:65–69
O’Sullivan CK and Guilbault GG (1999) Commercial quartz crystal microbalances—theory and applications. Biosens. Bioelectron. 14:663–670
Olsen EV (2000) Functional durability of a quartz crystal microbalance sensor for the rapid detection of Salmonella in liquids from poultry packaging. Masters Thesis. http://graduate.auburn.edu/auetd Auburn University, Alabama (accessed April 10, 2007)
Olsen EV (2005) Phage-coupled piezoelectric biodetector for Salmonella typhimurium. Doctoral Dissertation. http://graduate.auburn.edu/auetd Auburn University, Alabama (accessed April 10, 2007)
Olsen EV, Pathirana ST, Samoylov AM, Barbaree JM, Chin BA, Neely WC and Vodyanoy V (2003) Specific and selective biosensor for Salmonella and its detection in the environment. J. Microbiol. Methods 53:273–285
Olsen EV, Sorokulova IB, Petrenko VA, Chen IH, Barbaree JM and Vodyanoy VJ (2006) Affinity-selected filamentous bacteriophage as a probe for acoustic wave biodetectors of Salmonella typhimurium. Biosens. Bioelectron. 21:1434–1442
Olsen EV, Sykora JC, Sorokulova IB, Chen I-H, Neely WC, Barbaree JM, Petrenko VA and Vodyanoy VJ (2007) Phage fusion proteins as bioselective receptors for piezoelectric sensors. Electrochem. Soc. Trans. 2:9–25
Otto K, Elwing H and Hermansson M (1999) Effect of ionic strength on initial interactions of Escherichia coli with surfaces, studied on-line by a novel quartz crystal microbalance technique. J. Bacteriol. 181:5210–5218
Ozen A, Montgomery K, Jegier P, Patterson S, Daumer KA, Ripp SA, Garland JL and Sayler GS (2004) Development of bacteriophage-based bioluminescent bioreporters for monitoring of microbial pathogens. Proc. SPIE Int. Soc. Opt. Eng. 5270:58–68
Park I-S and Kim N (1998) Thiolated Salmonella antibody immobilization onto the gold surface of piezoelectric quartz crystal. Biosens. Bioelectron. 13:1091–1097
Park I-S, Kim W-Y and Kim N (2000) Operational characteristics of an antibody-immobilized QCM system detecting Salmonella spp. Biosens. Bioelectron. 15:167–172
Pathirana S, Myers LJ, Vodyanoy V and Neely WC (1996) Assembly of cadmium stearate and valinomycin molecules assists complexing of K+ in mixed Langmuir-Blodgett films. Supramol. Sci. 2:149–154
Pathirana S, Neely WC, Myers LJ and Vodyanoy V (1992) Interaction of valinomycin and stearic acid in monolayers. Langmuir 8:1984–1987
Pathirana S, Neely WC and Vodyanoy V (1998) Condensing and expanding the effects of the odorants (+)- and (-)-carvone on phospholipid monolayers. Langmuir 14:679–682
Pathirana ST (1993) Interaction of valinomycin and stearic acid in monolayers at the air/water interface. Doctoral Dissertation. Auburn University, Alabama
Pathirana ST, Barbaree J, Chin BA, Hartell MG, Neely WC and Vodyanoy V (2000) Rapid and sensitive biosensor for Salmonella. Biosens. Bioelectron. 15:135–141
Pattus F, Desnuelle P and Verger R (1978) Spreading of liposomes at the air/water interface. Biochim. Biophys. Acta 507:62–70
Pattus F and Rothen C (1981) Lipid-protein interactions in monolayers at the air-water interface. In: Azzi A, Brodbeck U, Zahler P (eds) Membrane Proteins. Springer-Verlag, Berlin pp 229–240
Pattus F, Rothen C, Streit M and Zahler P (1981) Further studies on the spreading of biomembranes at the air/water interface. Structure, composition, enzymatic activities of human erythrocyte and sarcoplasmic reticulum membrane films. Biochim. Biophys. Acta Biomembr. 647:29–39
Pavey KD (2002) Quartz crystal analytical sensors: the future of label-free, real-time diagnostics? Expert Rev. Mol. Diag. 2:173–186
Pavey KD, Ali Z, Olliff CJ and Paul F 1999. Application of the quartz crystal microbalance to the monitoring of Staphylococcus epidermidis antigen-antibody agglutination. J. Pharm. Biomed. Anal. 20:241–245
Pavey KD, Barnes L, Hanlon G, Olliff C, Ali Z and Paul F (2001) A rapid, non-destructive method for the determination of Staphylococcus epidermidis adhesion to surfaces using quartz crystal resonant sensor technology. Lett. Appl. Microbiol. 33:344–348
Pereira de Jesus D, Naves C and Lucia do Lago C (2002) Determination of boron by using a quartz crystal resonator coated with N-Methyl-D-glucamine-modified poly(epichlorohydrin). Anal. Chem. 74:3274–3280
Petrenko VA (2004) Personal communication.
Petrenko VA and Smith GP (2000) Phages from landscape libraries as substitute antibodies. Protein Eng. 13:589–592
Petrenko VA, Sorokulova IB, Chin BA, Barbaree JM, Vodyanoy VJ, Chen IH and Samoylov AM (2005) Biospecific peptide probes against Salmonella isolated from phage display libraries, and their diagnostic and drug delivery uses. US Patent Application 20050137136, filed Apr 29, 2004
Petrenko VA and Vodyanoy VJ (2003) Phage display for detection of biological threat agents. J. Microbiol. Methods 53:253–262
Petrenko VA, Vodyanoy VJ and Sykora JC (2007) Methods of forming monolayers of phage-derived products and uses thereof. US Patent # 7, 267, 993
Petty MC (1991) Application of multilayer films to molecular sensors: some examples of bioengineering at the molecular level. J. Biomed. Eng. 13:209–214
PM-740 Series Operation and Service Manual. (1996) Maxtek, Inc., Sante Fe Springs, California
Pohanka M and Skládal P (2005) Piezoelectric immunosensor for Francisella tularensis detection using immunoglobulin M in a limiting dilution. Anal. Lett. 38:411–422
Prusak-Sochaczewski E and Luong JHT (1990) Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium. Enzyme and Microb. Technol. 12:173–177
Pyun JC, Beutel H, Meyer JU and Ruf HH (1998) Development of a biosensor for E. coli based on a flexural plate wave (FPW) transducer. Biosens. Bioelectron 13:839–845
Qu X, Bao L, Su X and Wei W (1998) Rapid detection of Escherichia coliform with a bulk acoustic wave sensor based on the gelation of Tachypleus amebocyte lysate. Talanta 47:285–290
Ramirez E, Mas JM, Carbonell X, Aviles FX and Villaverde A (1999) Detection of molecular interactions by using a new peptide-displaying bacteriophage. Biosensor. Biochem. Biophys. Res. Commun. 262:801–805
Ramsden JJ (1997a) Dynamics of protein adsorption at the solid/liquid interface. Recent Res. Dev. Phys. Chem. 1:133–142
Ramsden JJ (1997b) Protein adsorption at the solid/liquid interface. Conference on Colloid Chemistry: In Memoriam Aladar Buzagh, Proceedings, 7th, Eger, Hung., Sept. 23–26, 1996, 148–151
Ramsden JJ (1998) Biomimetic protein immobilization using lipid bilayers. Biosens. Bioelectronics 13:593–598
Ramsden JJ (1999) On protein-lipid membrane interactions. Colloids Surfaces B Biointerfaces 14:77–81
Ramsden JJ (2001) Multiple interactions in protein-membrane binding. NATO Science Series, 335:244–269. IOS Press, Amsterdam
Rayleigh L (1885) On waves propagating along the plane surface of an elastic solid. Proc. London Math. Soc. 17:4–11
Reipa V, Almeida J and Cole KD (2006) Long-term monitoring of biofilm growth and disinfection using a quartz crystal microbalance and reflectance measurements. J. Microbiol. Methods 66:449–459
Rickert J, Gopel W, Hayward GL, Cavic BA and Thompson M (1999) Biosensors based on acoustic wave devices. Sens. Update 5:105–139
Roberts LM and Dunker AK (1993) Structural changes accompanying chloroform-induced contraction of the filamentous phage fd. Biochemistry 32:10479–10488
Samoylov AM, Samoylova TI, Hartell MG, Pathirana ST, Smith BF and Vodyanoy V (2002a) Recognition of cell-specific binding of phage display derived peptides using an acoustic wave sensor. Biomol. Eng. 18:269–272
Samoylov AM, Samoylova TI, Pathirana ST, Globa LP and Vodyanoy VJ (2002b) Peptide biosensor for recognition of cross-species cell surface markers. J. Mol. Recognit. 15:197–203
Sauerbrey GZZ (1959) Use of quartz vibrator for weighing thin films on a microbalance. Z. Phys. 155:206–212
Sayler GS, Ripp SA, Applegate BM (2003) Bioluminescent biosensor device. US Patent Application 20030027241, filed July 20, 2001
Scherz P (2000) Oscillators and Timers. McGraw-Hill, Inc., New York
Selz KA, Samoylova TI, Samoylov AM, Vodyanoy VJ and Mandell AJ (2006) Designing allosteric peptide ligands targeting a globular protein. Biopolymers 85:38–59
Si S, Lia X, Fungb Y and Zhub D (2001) Rapid detection of Salmonella enteritidis by piezoelectric immunosensor. Microchem. J. 68:21–27
Si S, Ren F, Cheng W and Yao S (1997) Preparation of a piezoelectric immunosensor for the detection of Salmonella paratyphi A by immobilization of antibodies on electropolymerized films. Fresenius J. Anal. Chem. 357:1101–1105
Skládal P (2003) Piezoelectric quartz crystal sensors applied for bioanalytical assays and characterization of affinity interactions. J. Braz. Chem. Soc. 14:491–502
Sobotka H and Trurnit HJ (1961) Need title of their article here. In: Alexander P, Block RJ (eds) Analytical Methods of Protein Chemistry. Pergamon Press, Oxford, UK, pp 212–243
Song M-J, Yun D-H, Jin J-H, Min N-K and Hong S-I (2006) Comparison of effective working electrode areas on planar and porous silicon substrates for cholesterol biosensor. Jpn. J. Appl. Phys. 45:7197–7202
Sorial J and Lec R (2004) A piezoelectric interfacial phenomena biosensor. Masters Thesis. http://dspace.library.drexel.edu/handle/1860/82 Drexel University, Pennsylvania (accessed April 10, 2007)
Sorokulova IB, Olsen EV, Chen IH, Fiebor B, Barbaree JM, Vodyanoy VJ, Chin BA and Petrenko VA (2005) Landscape phage probes for Salmonella typhimurium. J. Microbiol. Methods 63:55–72
Spangler BD, Wilkinson EA, Murphy JT and Tyler BJ (2001) Comparison of the Spreeta®surface plasmon resonance sensor and a quartz crystal microbalance for detection of Escherichia coli heat-labile enterotoxin. Anal. Chim. Acta 444:149–161
Stadler H, Mondon M and Ziegler C (2003) Protein adsorption on surfaces: dynamic contact angle (DCA) and quartz-crystal microbalance (QCM) measurements. Anal. Bioanal. Chem 375:53–61
Storri S, Santoni T and Mascini M (1998) A piezoelectric biosensor for DNA hybridisation detection. Anal. Lett. 31:1795–1808
Su C-C, Wu T-Z, Chen L-K, Yang H-H and Tai D-F (2003) Development of immunochips for the detection of dengue viral antigens. Anal. Chim. Acta 479:117–123
Su X-L and Li SFY (2001) Serological determination of Helicobacter pylori infection using sandwiched and enzymatically amplified piezoelectric biosensor. Anal. Chim. Acta 429:27–36
Su X-L and Li Y (2004) A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7. Biosens. Bioelectron. 19:563–574
Su X-L and Li Y (2005) A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance. Biosens. Bioelectron. 21:840–848
Su X, Low S, Kwang J, Chew VHT and Li SFY (2001) Piezoelectric quartz crystal based veterinary diagnosis for Salmonella enteritidis infection in chicken and egg. Sens. Actuators B 75:29–35
Sukhorukov GB, Montrel MM, Petrov AI, Shabarchina LI and Sukhorukov BI (1996) Multilayer films containing immobilized nucleic acids. Their structure and possibilities in biosensor applications. Biosens. Bioelectron. 11:913–922
Sykora JC (2003) Monolayers of biomolecules for recognition and transduction in biosensors. Doctoral Dissertation. Auburn University, Al. http://graduate.auburn.edu/auetd (accessed April 10, 2007)
Sykora JC, Neely WC and Vodyanoy V (2004) Solvent effects on amphotericin B monolayers. J. Colloid Interface Sci. 269:499–502
Tabacco MB, Qian X and Russo J (2004) Fluorescent virus probes for identification of bacteria. US Patent Application 20040191859, filed Mar 24, 2003
Tai D, Lin C, Wu T, Huang J and Shu P (2006) Artificial receptors in serologic tests for the early diagnosis of dengue virus infection. Clin. Chem. 58:1486–1491
Tan H, Deng L, Nie L and Yao S (1997) Detection and analysis of the growth characteristics of Proteus vulgaris with a bulk acoustic wave ammonia sensor. Analyst 122:179–184
Thompson M, Arthur C and Dhaliwal G (1986) Liquid-phase piezoelectric and acoustic transmission studies of interfacial immunochemistry. Anal. Chem. 58:1206–1209
Thompson M, Kiplingt A, Duncan-Hewitt W, Rajakovic L and Cavic-Vlasak B (1991) Thickness-shear-mode acoustic wave sensors in the liquid phase: a review. Analyst 116:881–890
Thust M, Schoning MJ, Schroth P, Malkoc U, Dicker CI, Steffen A, Kordos P and Luth H (1999) Enzyme immobilization on planar and porous silicon substrates for biosensor applications. J. Mol. Catal. B: Enzym. 7:77–83
Tiefenauer LX, Kossek S, Padeste C and Thiebaud P (1997) Towards amperometric immunosensor devices. Biosens. Bioelectron. 12:213–223
Trurnit HJ (1960) The spreading of protein monolayers. J. Colloid Sci. 15:1–13
Umezawa Y (1996) CRC handbook of ion-selective electrodes: selectivity coefficients. CRC Press, Boca Raton, Florida
Uttenthaler E, Kolinger C and Drost S (1998) Quartz crystal biosensor for detection of the African Swine Fever disease. Anal. Chim. Acta 362:91–100
Uttenthaler E, Schraml M, Mandel J and Drost S (2001) Ultrasensitive quartz crystal microbalance sensors for detection of M13-Phages in liquids. Biosens. Bioelectronics 16:735–743
Uzawa H, Kamiya S, Minoura N, Dohi H, Nishida Y, Taguchi K, Yokoyama S, Mori H, Shimizu T and Kobayashi K (2002) A quartz crystal microbalance method for rapid detection and differentiation of shiga toxins by applying a monoalkyl globobioside as the toxin ligand. Biomacromolecules 3:411–414
Vaughan RD, O’Sullivan CK and Guilbault GG (2001) Development of a quartz crystal microbalance (QCM) immunosensor for the detection of Listeria monocytogenes. Enzyme Microb. Technol. 29:635–638
Vaughan TJ, Williams AJ, Pritchard K, Osbourn JK, Pope AR, Earnshaw JC, McCafferty J, Hodits RA, Wilton J and Johnson KS (1996) Human antibodies with sub-nanomolar affinities isolated from a large non-immunized phage display library. Nature Biotechnol. 14:309–314
Victorov IA (1967) Rayleigh and Lamb Waves—physical theory and applications. Plenum Press, New York
Vig J and Ballato A (1998) Comments about the effects of non-uniform mass loading on a quartz crystal microbalance. IEEE Trans. Ultrason. Ferroelectrics Freq. Contr. 45:1123–1124
Vodyanoy V (1994) Functional reconstitution of mammalian olfactory receptor. Report. ARO-27364.10-LS
Voinova MV, Jonson M and Kasemo B (2002) “Missing mass” effect in biosensor’s QCM applications. Biosens. Bioelectron. 17:835–841
Volker M and Siegmund HU (1997) Forster energy transfer in ultrathin polymer layers as a basis for biosensors. EXS 80:175–191
Wang J, Fu W, Liu M, Wang Y, Xue Q, Huang J and Zhu Q (2002) Multichannel piezoelectric genesensor for the detection of human papilloma virus. Chinese Med. J. (Engl) 115:439–442
White RM and Voltmer FW (1965) Direct piezoelectric coupling to surface elastic waves. Appl. Phys. Lett. 7:314–316
Wong YY, Ng SP, Ng MH, Si SH, Yao SZ and Fung YS (2002) Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance. Biosens. Bioelectron. 17:676–684
Wu T-Z, Su C-C, Chen L-K, Yang H-H, Tai D-F and Peng K-C (2005) Piezoelectric immunochip for the detection of dengue fever in viremia phase. Biosens. Bioelectron. 21:689–695
Wu Z-Y, Shen G-L, Li Z-Q, Wang S-P and Yu R-Q (1999) A direct immunoassay for Schistosoma japonium antibody (SjAb) in serum by piezoelectric body acoustic wave sensor. Anal. Chim. Acta 398:57–63
Wu Z, Wu J, Wang S, Shen G and Yu R (2006) An amplified mass piezoelectric immunosensor for Schistosoma japonicum. Biosens. Bioelectron. 22:207–212
Xomeritakis G, Liu NG, Chen Z, Jiang YB, Koehn R, Johnson PE, Tsai CY, Shah PB, Khalil S, Singh S and Brinker CJ (2007) Anodic alumina supported dual-layer microporous silica membranes. J. Membr. Sci. 287:157–161
Yakhno T, Sanin A, Pelyushenko A, Kazakov V, Shaposhnikova O, Chernov A, Yakhno V, Vacca C, Falcione F and Johnson B (2007) Uncoated quartz resonator as a universal biosensor. Biosens. Bioelectron. 22:2127–2131
Yao S, Tan H, Zhang H, Su X and Wei W (1998) Bulk acoustic wave bacterial growth sensor applied to analysis of antimicrobial properties of tea. Biotechnol. Prog. 14:639–644
Ye J, Letcher S and Rand AG (1997) Piezoelectric biosensor for the detection of Salmonella typhimurium. J. Food Sci. 62:1067–1071, 1086
Yilma S, Cannon-Sykora J, Samoylov A, Lo T, Liu N, Brinker CJ, Neely WC and Vodyanoy V (2007a) Large-conductance cholesterol-amphotericin B channels in reconstituted lipid bilayers. Biosens. Bioelectron. 22:1359–1367
Yilma S, Liu N, Samoylov A, Lo T, Brinker CJ and Vodyanoy V (2007b) Amphotericin B channels in phospholipid membrane-coated nanoporous silicon surfaces: implications for photovoltaic driving of ions across membranes. Biosens. Bioelectron. 22:1605–1611
Ying-Sing F, Shi-Hui S and De-Rong Z (2000) Piezoelectric crystal for sensing bacteria by immobilizing antibodies on divinylsulphone activated poly-m-aminophenol film. Talanta 51:151–158
Yun D-H, Song M-J, Hong S-I, Kang M-S and Min N-K (2005) Highly sensitive and renewable amperometric urea sensor based on self-assembled monolayer using porous silicon substrate. J. Kor. Phys. Soc. 47:S445–S449
Zhang J, Xie Y, Dai X, Wei W (2001) Monitoring of Lactobacillus fermentation process by using ion chromatography with a series piezoelectric quartz crystal detector. J. Microbiol. Methods 44:105–111
Zhang S, Wei W, Zhang J, Mao Y and Liu S (2002) Effect of static magnetic field on growth of Escherichia coli and relative response model of series piezoelectric quartz crystal. Analyst 127:373–377
Zhao J, Zhu W and He F (2005) Rapidly determining E. coli and P. aeruginosa by an eight channels bulk acoustic wave impedance physical biosensor. Sens. Actuators B 107: 271–276
Zhou X, Liu L, Hu M, Wang L and Hu J (2002) Detection of hepatitis B virus by piezoelectric biosensor. J. Pharmaceut. Biomed. Anal. 27:341–345
Zuo B, Li S, Guo Z, Zhang J and Chen C (2004) Piezoelectric immunosensor for SARS-associated coronavirus in sputum. Anal. Chem. 76:3536–3540
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer Science+Business Media, LLC
About this chapter
Cite this chapter
Olsen, E., Vainrub, A., Vodyanoy, V. (2008). Acoustic Wave (TSM) Biosensors: Weighing Bacteria. In: Zourob, M., Elwary, S., Turner, A. (eds) Principles of Bacterial Detection: Biosensors, Recognition Receptors and Microsystems. Springer, New York, NY. https://doi.org/10.1007/978-0-387-75113-9_12
Download citation
DOI: https://doi.org/10.1007/978-0-387-75113-9_12
Publisher Name: Springer, New York, NY
Print ISBN: 978-0-387-75112-2
Online ISBN: 978-0-387-75113-9
eBook Packages: EngineeringEngineering (R0)