Abstract
High capacity pulse tube coolers are presently under development at CEA/SBT. The Development Models of the pulse tube cold finger feature an in-line configuration to ease manufacturing and optimisation of the sizing.
A cooling power of 5.2 W at 80 K has been achieved with 200 W of total electrical power, 128 W PV work, and a rejection temperature of 298 K provided by water cooling. This work has been accomplished using a standard wearing linear compressor operating at a fixed frequency of 50 Hz and equipped with a laser transducer to measure the stroke. An ultimate temperature of 38 K has also been achieved.
Based on these results, a pulse tube cold finger has been developed for cooling down of HTS filters banks for an UMTS RF base station demonstrator (SUPRACOM project). A standard wearing linear compressor from THALES Cryogenics with an adjustable frequency drive electronics has been used. A performance of 7.7 W at 80 K has been achieved with 200 W of total electrical power and with heat rejection at 298 K; the PV work is about 140 W. This last result is presently being used for the design of a coaxial shape pulse tube cooler. This cold finger will be ultimately supplied with a flexure bearing compressor to increase the reliability. The matching of the compressor and the cold head are discussed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
S.W. Zhu, S.L. Zhou, N. Yoshimura and Y. Matsubara, “Phase shift effect of the long neck tube for pulse tube refrigerator,” Cryocoolers 9, Plenum Press, New York (1997), pp. 269–278
D.L. Gardner and G.W. Swift, “Use of inertance in orifice pulse tube refrigerators,” Cryogenics, vol. 37 (1997), pp. 117–121.
D. Gedeon, “DC gas flows in Stirling and pulse tube refrigerators,” Cryocoolers 9, Plenum Press, New York (1997), pp 385–392.
L. Duband, et al., “Experimental results on inertance and permanent flow in pulse tube coolers,” Cryocoolers 10, Plenum Press, New York (1999), pp 281–290.
G. Thummes, M. Schreiber, R. Landgraf and C. Heiden, “Convective heat losses in pulse tube coolers: effect of pulse tube inclination,” Cryocoolers 9, Plenum Press, New York (1997), pp. 385
L.W. Yang and G. Thummes, “Medium-size pulse tube coolers with linear compressor,” Adv. in Cryogenic Engineering, Vol. 47, Amer. Institute of Physics, Melville, NY (2002).
S-Y Kim, W-S Chung, J-J Park, D-K Hwang, H-K Lee, “Reliability test results of LGE pulse tube cryoccoler,” Adv. in Cryogenic Engineering, Vol. 47, Amer. Institute of Physics, Melville, NY (2002).
M. Meijers, A. A. J. Benschop and J. C. Mullié, “High Reliability Coolers under development at Signaal-USFA,” Cryocoolers 11, Kluwer Academic / Plenum Publishers, New York (2001), pp 111–118.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2003 Kluwer Academic Publishers
About this chapter
Cite this chapter
Charles, I., Duvaland, J.M., Duband, L., Trollier, T., Ravex, A., Martin, J.Y. (2003). High Capacity Pulse Tube Cryocooler. In: Ross, R.G. (eds) Cryocoolers 12. Springer, Boston, MA. https://doi.org/10.1007/0-306-47919-2_19
Download citation
DOI: https://doi.org/10.1007/0-306-47919-2_19
Publisher Name: Springer, Boston, MA
Print ISBN: 978-0-306-47714-0
Online ISBN: 978-0-306-47919-9
eBook Packages: Springer Book Archive