Abstract
Background:
The treatment of open fractures leads to major problems which may be due to various reasons. It mainly causes soft tissue problems due to the absorption of a large amount of energy by the soft tissues and bone tissues. Although some recent treatment protocols have eliminated many problems regarding delayed soft tissue closure, it still remains a big challange. This study uses a method called the internal fixator technique with noncontact locking plate (NC-LP) which involves the use of a combination of advantages of open and closed fixation techniques.
Materials and Methods:
42 patients (32 men and 10 women) having a mean age of 34.11 years (range 17–56 years) with open fractures operated using internal fixator technique between 2007 and 2012 were included in this study. A retrospective chart review was conducted to record the following: age, gender, anatomic region of fractures, fracture etiology, classification of open fractures by Gustilo–Anderson and AO classification, surgeries, length of hospitalization, location and pattern of fracture, length of followup, and complications.
Results:
The fractures were caused by traffic accidents, shotgun injuries, falls from heights, and industrial crush injuries. Based on the Gustilo–Anderson classification, 31 fractures were Type III and 11 were Type II, where 23 were localized in the tibia and 19 in the femur. Patients delay for a mean of 13.5 h (range 6–24 h) for operation and the mean followup interval was 27.8 months (range 16–44 months). The mean union time was 19.7 weeks (range 16–29 weeks). One patient had delayed union and implant failure, one patient had osteomyelitis, five suffered from surface skin necrosis, and one patient had an angulation of 17° in the sagittal plane, for which no additional intervention was performed.
Conclusions:
This case series demonstrates that an “internal fixator technique” is an acceptable alternative to the management of open fractures of the femur or tibia in adult patients. The NC-LP method provided opportunities to achieve a stable fixation with noncontact between the implant and the bone tissues, and the fractures were sufficiently stabilized to allow union with a low complication rate.
Similar content being viewed by others
References
Tielinen L, Lindahl JE, Tukiainen EJ. Acute unreamed intramedullary nailing and soft tissue reconstruction with muscle flaps for the treatment of severe open tibial shaft fractures. Injury 2007;38:906–12.
Gopal S, Majumder S, Batchelor AG, Knight SL, De Boer P, Smith RM. Fix and flap: The radical orthopaedic and plastic treatment of severe open fractures of the tibia. J Bone Joint Surg Br 2000;82:959–66.
Byrd HS, Cierny G 3rd, Tebbetts JB. The management of open tibial fractures with associated soft-tissue loss: External pin fixation with early flap coverage. Plast Reconstr Surg 1981;68:73–82.
Bhandari M, Guyatt GH, Swiontkowski MF, Schemitsch EH. Treatment of open fractures of the shaft of the tibia. A systematic overview and meta-analysis. J Bone Joint Surg 2001;83:62–8.
Henley MB, Chapman JR, Agel J, Harvey EJ, Whorton AM, Swiontkowski MF. Treatment of type II, IIIA, and IIIB open fractures of the tibial shaft: A prospective comparison of unreamed interlocking intramedullary nails and half-pin external fixators. J Orthop Trauma 1998;12:1–7.
Cordero-Ampuero J. The management of open fractures of the tibial diaphysis. Eur Instr Course Lect 2007;8:42–8.
Berkes M, Obremskey WT, Scannell B, Ellington JK, Hymes RA, Bosse M; Southeast Fracture Consortium. Maintenance of hardware after early postoperative infection following fracture internal fixation. J Bone Joint Surg Am 2010;92:823–8.
Leach RE. Fractures of the tibia and fibula. In: Rockwood CA Jr., Green DP, editors. Fractures in Adults. Philadelphia: J. B. Lippincott; 1984. p. 1593–603.
Ketonis C, Barr S, Adams CS, Hickok NJ, Parvizi J. Bacterial colonization of bone allografts: Establishment and effects of antibiotics. Clin Orthop Relat Res 2010;468:2113–21.
Kesemenli CC, Kapukaya A, Subasi M, Arslan H, Necmioglu S, Kayikçi C. Early prophylactic autogenous bone grafting in type III open tibial fractures. Acta Orthop Belg 2004;70:327–31.
Cleber C, Haas NP. Biologics in open fracture. Eur Instr Course Lect 2013;13:73–82.
Hertel R, Lambert SM, Müller S, Ballmer FT, Ganz R. On the timing of soft-tissue reconstruction for open fractures of the lower leg. Arch Orthop Trauma Surg 1999;119:7–12.
Zalavras CG, Patzakis MJ, Holtom PD, Sherman R. Management of open fractures. Infect Dis Clin North Am 2005;19:915–29.
Worlock P, Slack R, Harvey L, Mawhinney R. The prevention of infection in open fractures: An experimental study of the effect of fracture stability. Injury 1994;25:31–8.
Eijer H, Hauke C, Arens S, Printzen G, Schlegel U, Perren SM. PC-fix and local infection resistance – Influence of implant design on postoperative infection development, clinical and experimental results. Injury 2001;32 Suppl 2:B38–43.
Wiss DA, Stetson WB. Unstable fractures of the tibia treated with a reamed intramedullary interlocking nail. Clin Orthop Relat Res 1995;315:56–63.
Melcher GA, Metzdorf A, Schlegel U, Ziegler WJ, Perren SM, Printzen G. Influence of reaming versus nonreaming in intramedullary nailing on local infection rate: Experimental investigation in rabbits. J Trauma 1995;39:1123–8.
Brinker MR, Cook SD, Dunlap JN, Christakis P, Elliott MN. Early changes in nutrient artery blood flow following tibial nailing with and without reaming: A preliminary study. J Orthop Trauma 1995;39:1123–8.
Klein MP, Rahn BA, Frigg R, Kessler S, Perren SM. Reaming versus non-reaming in medullary nailing: Interference with cortical circulation of the canine tibia. Arch Orthop Trauma Surg 1990;109:314–6.
Schemitsch EH, Kowalski MJ, Swiontkowski MF, Senft D. Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: A fractured tibia model in sheep. J Orthop Trauma 1994;8:373–82.
Ochsner PE, Hailemariam S. Histology of osteosynthesis associated bone infection. Injury 2006;37 Suppl 2:S49–58.
Papakostidis C, Kanakaris NK, Pretel J, Faour O, Morell DJ, Giannoudis PV. Prevalence of complications of open tibial shaft fractures stratified as per the Gustilo-Anderson classification. Injury 2011;42:1408–15.
Tornetta P 3rd, Bergman M, Watnik N, Berkowitz G, Steuer J. Treatment of grade-IIIb open tibial fractures. A prospective randomised comparison of external fixation and non-reamed locked nailing. J Bone Joint Surg Br 1994;76:13–9.
Schlegel U, Perren SM. Surgical aspects of infection involving osteosynthesis implants: Implant design and resistance to local infection. Injury 2006;37 Suppl 2:S67–73.
Oosterbos CJ, Vogely HC, Nijhof MW, Fleer A, Verbout AJ, Tonino AJ, et al. Osseointegration of hydroxyapatite-coated and noncoated Ti6Al4V implants in the presence of local infection: A comparative histomorphometrical study in rabbits. J Biomed Mater Res 2002;60:339–47.
Sanders R, Jersinovich I, Anglen J, DiPasquale T, Herscovici D Jr., The treatment of open tibial shaft fractures using an interlocked intramedullary nail without reaming. J Orthop Trauma 1994;8:504–10.
Oh CW, Park BC, Ihn JC, Park HJ. Primary unreamed intramedullary nailing for open fractures of the tibia. Int Orthop 2001;24:338–41.
Kakar S, Tornetta P 3rd. Open fractures of the tibia treated by immediate intramedullary tibial nail insertion without reaming: A prospective study. J Orthop Trauma 2007;21:153–7.
Ahmad M, Nanda R, Bajwa AS, Candal-Couto J, Green S, Hui AC. Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? Injury 2007;38:358.
Author information
Authors and Affiliations
Corresponding author
Additional information
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Rights and permissions
About this article
Cite this article
Yıldırım, A., Kapukaya, A., Mertsoy, Y. et al. Management of open fractures using a noncontact locking plate as an internal fixator. IJOO 51, 312–317 (2017). https://doi.org/10.4103/0019-5413.205686
Published:
Issue Date:
DOI: https://doi.org/10.4103/0019-5413.205686