Abstract
Background
Anterior fixation using two 3.5 mm screws is typically recommended for type II odontoid fractures. However, it is unsuitable in patients with an odontoid diameter of <9.0 mm. There is no data regarding the morphology of odontoid process in the Indian population. The aim of our study was to: a) Measure the external diameters of odontoid process in the Indian population using CT scan and thus determine the feasibility of two 3.5 mm screw fixation in them. b) Determine if any correlation exists between body height (Ht) and weight (Wt) and external odontoid diameters.
Materials and Methods
CT images of odontoid process of 100 consecutive patients were analyzed. Antero- posterior (AP) and transverse (TD), outer diameters of the odontoid process were measured from the base and at 1 mm interval upwards on axial CT images.
Results
The mean AP and mean TD were 11.52 mm and 9.85 mm, respectively. Fifty-five (55%) of the patients had at least one TD <9.0 mm. Five (5%) patients had at least one TD <7.4 mm. None of the patients had any diameter <5.5 mm. Body Ht correlated significantly with mean AP and mean TD of the odontoid process (AP: r = 0.276, P = 0.013; TD: r = 0.359, P = 0.001), whereas body Wt correlated significantly only with mean TD (AP: r = 0.162, P = 0.15; TD: r = 0.297, P = 0.007).
Conclusion
More than half of the study population (55%) was unsuitable for two 3.5 mm screw fixation for type II odontoid fracture. Two 2.7 mm screws can be safely used in 95% of the population. A 4.5 mm Herbert screw can be safely used in the entire population. We recommend two 2.7 mm screws or a 4.5 mm Herbert screw for fixation of these fractures in the Indian population. Body height showed a significant correlation with external odontoid diameters, whereas weight showed significant correlation only with TD of the odontoid process.
Similar content being viewed by others
References
Anderson LD, D’ Alonzo RT. Fractures of the odontoid process of the axis. J Bone Joint Surg Am 1974;56:1663–74.
Jenkins JD, Coric D, Branch CL. A clinical comparison of one and two screw odontoid fixation. J Neurosurg 1998;89:366–70.
Esses SI, Bednar DA. Screw fixation of odontoid fractures and nonunions. Spine (Phila Pa 1976) 1991;16 Suppl 10:S483–5.
Henry AD, Bohly J, Grosse A. Fixation of odontoid fractures by an anterior screw. J Bone Joint Surg Br 1999;81:472–7.
Sasso R, Doherty BJ, Crawford MJ, Heggeness MH. Biomechanics of odontoid fracture fixation. Spine (Phila Pa 1976) 1993;18:1950–3.
Schaffler MB, Alson MD, Heller JG, Garfin SR. Morphology of the Dens. Spine (Phila Pa 1976) 1992;17:738–43.
Yusof MI, Yusof AH, Abdullah MS, Hussain TM. Computed tomographic evaluation of the odontoid process for two screw fixation in type II fracture: A Malaysian perspective. J Orthop Surg (Hong Kong) 2007;15:67–72.
Jeanneret B, Vernet O, Frei S, Magerl F. Atlantoaxial mobility after screw fixation of the odontoid: A computed tomographic study. J Spinal Disord 1991;4:203–11.
Bohler J. Anterior stabilization for acute fractures and nonunions of the dens. J Bone Joint Surg Am 1982;6:18–27.
Nakanishi T, Sasaki T, Tokita N, Hirabayashi K. Internal fixation for the odontoid fracture. Orthop Trans 1982;6:176.
Aebi M, Etter C, Coscia M. Fractures of the odontoid process: Treatment with anterior screw fixation. Spine (Phila Pa 1976) 1989;14:1065–70.
Nucci RC, Seigal S, Merola AA, Gorup J, Mroczek KJ, Dryer J, et al. Computed tomographic evaluation of the normal adult odontoid: Implications for internal fixation. Spine (Phila Pa 1976) 1995;20:264–70.
Daher MT, Daher S, Nogueira-Barbosa MH, Defino HL. Computed tomographic evaluation of odontoid process: Implications for anterior screw fixation of odontoid fractures in an adult population. Eur Spine J 2011;20:1908–14.
Chadha M, Balain B, Maini L, Dhaon BK. Pedicle morphology of the lower thoracic, lumbar and S1 vertebrae: An Indian perspective. Spine (Phila Pa 1976) 2003;28:744–9.
Apuzzo ML, Heiden JS, Weiss MH, Ackerson TT, Harvey JP, Kurze T. Acute fractures of the odontoid process: An analysis of 45 cases. J Neurosurg 1978;48:85–91.
El Saghir H, Bohm H. Anderson type II fracture of the odontoid process: Results of anterior screw fixation. J Spinal Disord 2000;13:527–31.
McBride AD, Mukherjee DP, Kruse RN, Albright JA. Anterior screw fixation of type II odontoid fractures: A biomechanical study. Spine (Phila Pa 1976) 1995;20:1855–60.
Shaw JA. Biomechanical comparison of cannulated small bone screws: A brief followup study. J Hand Surg Am 1991;16:998–1001.
Lee SH, Sung JK. Anterior Odontoid fixation using a 4.5 mm Herbert screw: The first report of 20 consecutive cases with Odontoid fracture. Surg Neurol 2006;66:361–6.
Xu R, Nadaud MC, Ebraheim NA, Yeasting RA. Morphology of the second cervical vertebra and posterior projection of the C2 pedicle axis. Spine (Phila Pa 1976) 1995;20:259–63.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kulkarni, A.G., Shah, S.M., Marwah, R.A. et al. CT based evaluation of odontoid morphology in the Indian population. IJOO 47, 250–254 (2013). https://doi.org/10.4103/0019-5413.111511
Published:
Issue Date:
DOI: https://doi.org/10.4103/0019-5413.111511