Skip to main content
Log in

Compensation for z-directional non-uniformity of a monopole antenna at 7T MRI

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

The research was conducted to find ways to compensate for z-directional non-uniformity at a monopole antenna array (MA) coil by using a tilted optimized non-saturating excitation (TONE) pulse and to evaluate the feasibility of using the MA coil with the TONE pulse for anatomical and angiographic imaging. The sensitivity of a MA coil along the z-direction was measured by using an actual flip angle imaging pulse sequence with an oil phantom to evaluate the flip angle distributions of the MA coil for 7T magnetic resonance imaging (MRI). The effects on the z-directional uniformity were examined by using slow and fast TONE pulses, i.e., TONE SLOW and TONE FAST. T1- and T2* -weighted images of the human brain were also examined. The z-directional profiles of the TONE pulses were analyzed by using the average signal intensity throughout the brain. The effect of the TONE pulses on cerebral vessels was further examined by analyzing maximal intensity projections of T1-weighted images. With increasing the applied flip angles, the sensitivity slope slightly increased (0.044 per degree). For the MA coil, the TONE SLOWpulse yielded a compensated profile along the z-direction while the TONE HIGH pulse, which has a flat excitation profile along the z-direction, exhibited a tilted signal intensity toward the coil end, clearly indicating an intrinsic property of the MA coil. Similar to the phantom study, human brain images revealed z-directional symmetry around the peak value for the averaged signal intensity of the TONE SLOW pulse while the TONE HIGH pulse exhibited a tilted signal intensity toward the coil end. In vascular system imaging, the MA coil also clearly demonstrated a beneficial effect on the cerebral vessels, either with or without the TONE pulses. This study demonstrates that TONE pulses could compensate for the intrinsic z-directional non-uniformity of MA coils that exhibit strong uniformity in the x-y plane. Furthermore, tilted pulses, such as TONE pulses, were utilized for visualizing small vessels. Appropriately combining MA coils and TONE pulses could help advance micro-vessel visualization.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Z. H. Cho, C. K. Kang, J. Y. Han, S. H. Kim, K. N. Kim, S. M. Hong, C. W. Park and Y. B. Kim, Stroke 39, 1604 (2008).

    Article  Google Scholar 

  2. G. A. Kerchner, J. Alzheimers Dis. 26, 91 (2011).

    Article  Google Scholar 

  3. D. H. Kwon et al., Ann. Neurol. 71, 267 (2012).

    Article  Google Scholar 

  4. A. J. E. Raaijmakers, O. Ipek, D.W. J. Klomp, C. Possanzini, P. R. Harvey, J. J. W. Lagendijk and C. A. T. van den Berg, Magn. Reson. Med. 66, 1488 (2011).

    Article  Google Scholar 

  5. G. Adriany, P. F. Van de Moortele, J. Ritter, S. Moeller, E. J. Auerbach, C. Akgün, C. J. Snyder, T. Vaughan and K. Ugurbil, Magn. Reson. Med. 59, 590 (2008).

    Article  Google Scholar 

  6. G. J. Metzger, C. Snyder, C. Akgun, T. Vaughan, K. Ugurbil and P. F. Van de Moortele, Magn. Reson. Med. 59, 396 (2008).

    Article  Google Scholar 

  7. I. M. L. van Kalleveen, V. O. Boer, P. R. Luijten and D. W. J. Klomp, Magn. Reson. Med. 74, 482 (2015).

    Article  Google Scholar 

  8. H. Watanabe, N. Takaya and F. Mitsumori, J. Magn. Reson. 212, 426 (2011).

    Article  ADS  Google Scholar 

  9. G. C. Wiggins, C. Triantafyllou, A. Potthast, A. Reykowski, M. Nittka and L. L. Wald, Magn. Reson. Med. 56, 216 (2006).

    Article  Google Scholar 

  10. G. C. Wiggins, J. R. Polimeni, A. Potthast, M. Schmitt, V. Alagappan and L. L. Wald, Magn. Reson. Med. 62, 754 (2009).

    Article  Google Scholar 

  11. C. M. Collins et al., Magn. Reson. Med. 47, 1026 (2002).

    Article  Google Scholar 

  12. Q. X. Yang et al., Magn. Reson. Med. 47, 982 (2002).

    Article  Google Scholar 

  13. H. Mihara, N. Iriguchi and S. Ueno, J. Appl. Phys. 97, 10R305 (2005).

    Google Scholar 

  14. N. I. Avdievich, H. P. Hetherington, A. M. Kuznetsov and J. W. Pan, J. Magn. Reson. Imaging 29, 461 (2009).

    Article  Google Scholar 

  15. S. M. Hong, J. H. Park, M. K. Woo, Y. B. Kim and Z. H. Cho, Magn. Reson. Med. 71, 1944 (2014).

    Article  Google Scholar 

  16. X. Yan, X. Zhang, L. Wei and R. Xue, Quant. Imaging Med. Surg. 4, 79 (2014).

    Google Scholar 

  17. M. K. Woo, S. M. Hong, J. Lee, C. K. Kang, S. Y. Park, Y. D. Son, Y. B. Kim and Z. H. Cho, Magn. Reson. Med. 76, 2566 (2016).

    Article  Google Scholar 

  18. X. Yan, R. Xue and X. Zhang, Quant. Imaging Med. Surg. 4, 225 (2014).

    Google Scholar 

  19. I. Ikushima, Y. Korogi, T. Hirai and M. Takahashi, Acta Radiol. 38, 275 (1997).

    Google Scholar 

  20. G. H. Roditi, F. W. Smith and T. W. Redpath, Br. J. Radiol. 67, 11 (1994).

    Article  Google Scholar 

  21. V. L. Yarnykh, Magn. Reson. Med. 57, 192 (2007).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chang-Ki Kang.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, N., Woo, MK. & Kang, CK. Compensation for z-directional non-uniformity of a monopole antenna at 7T MRI. Journal of the Korean Physical Society 68, 1352–1358 (2016). https://doi.org/10.3938/jkps.68.1352

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.68.1352

Keywords

Navigation