Abstract
Features and engineering aspects associated with the development of variable-frequency electric drives are considered. The results of an investigation of their characteristics are presented. The electric drives are used in main circulation pumps that ensure the transportation of a liquid-metal coolant in a 25-MW nuclear power plant.
Similar content being viewed by others
References
Mitenkov, F.M., Novinskii, E.G., and Burov, V.M., Glavnye tsirkulyatsionnye nasosy AES (Main Circulation Pumps of Nuclear Power Plants), Moscow: Energoatomizdat, 1984.
Anishev, E.Yu., Lazarev, G.B., and Sultanov, A.Y., Specific Features of Application of an Asynchronous Frequency-Variable Electric Drive of the Circulation Pumps if a Special-Purpose Power Plant, Vestnik VNIIE, 2003, pp. 149–159.
Anishev, E.Yu., Khvostov, S.V., Titov, V.G., et al., Torsion Vibrations of Pump Units with an Electric Drive Connected According to the Scheme of Asynchronous Valve Cascade, Elektrichestvo, 1987, no. 2, pp. 54–57.
Zagorskii, A.E., Reguliruemye elektricheskie mashiny peremennogo toka (Adjustable Alternating-Current Electric Machines), Moscow: Energoatomizdat, 1992.
Connors, D., Jarc, D., and Daugherty, R., Considerations in Applying Induction Motors with Solid-State Adjustable Frequency Controllers, IEEE. Transactions on Industry Applications, 1984, vol. 1A-20, no. 1, pp. 113–121.
Venkatesan, R. and Lindsay, J., Comparative Study of the Losses in Voltage and Current Source Inverer Fed Induction Motors, IEEE Transactions on Industry Applications, 1982, vol. 1A-18, no. 3, pp. 240–245.
Lazarev, G.B., Electromagnetic Compatibility of Application of Frequency-Variable Asynchronous Electric Drives in Systems of Power Supply for Auxiliaries of a Power Electric Plant, Vestnik VNIIE, 2000, pp. 55–69.
Lazarev, G.B., Electromagnetic Compatibility of High-Voltage Frequency Converters with Power Supply Systems and Electric Motors for Auxiliaries of Heat Power Plants, EUSA, 2004, no. 10, pp. 33–42.
Additional information
Original Russian Text © A.T. Sultanov, 2007, published in Elektrotekhnika, 2007, No. 5, pp. 41–46.
About this article
Cite this article
Sultanov, A.T. Variable-frequency asynchronous drive used in circulation pumps of a power-generating plant. Russ. Electr. Engin. 78, 256–260 (2007). https://doi.org/10.3103/S1068371207050069
Issue Date:
DOI: https://doi.org/10.3103/S1068371207050069