Skip to main content
Log in

Cosmic-ray calibration of lead scintillation monitor with internal trigger

  • Published:
Bulletin of the Lebedev Physics Institute Aims and scope Submit manuscript

Abstract

Cosmic-ray calibration of the 4-channel lead scintillation monitor with internal trigger shows that the consideration of only coinciding signals of counters placed in the monitor depth and detecting the final part of the high-energy photon shower, with signals of any other counters at the monitor top, detecting both the initial part of the high-energy photon shower and low-energy background photons, decreases the number of detected coincidences by a factor of 2–4. An increase in the number of such coincidences when using the monitor in the setup for studying neutral pion photoproduction on nuclei in the photon beam of the labeling system of the “PAKHRA” accelerator of the Lebedev Physical Institute makes it possible to separate the high-energy electromagnetic shower from the low-energy background and to monitor the beam photon energy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. V. A. Baskov, Yu. A. Bashmakov, A.V. Verdi, et al., Preprint No. 12, FIAN(Lebedev Physical Institute, Russian Academy of Sciences, Moscow, 1997).

  2. V. A. Baskov, B. B. Govorkov, V. A. Karpov, et al., Preprint No. 5, FIAN (Lebedev Physical Institute, Russian Academy of Sciences, Moscow, 2006).

  3. V. A. Baskov, A. V. Verdi, B. B. Govorkov, et al., Preprint No. 23, FIAN (Lebedev Physical Institute, Russian Academy of Sciences, Moscow, 2000).

  4. V. A. Baskov, A. V. Verdi, B. B. Govorkov, et al., Preprint No. 37, FIAN (Lebedev Physical Institute, Russian Academy of Sciences, Moscow, 1999).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. A. Baskov.

Additional information

Original Russian Text © V.A. Baskov, B.B. Govorkov, V.V. Polyanskii, 2014, published in Kratkie Soobshcheniya po Fizike, 2014, Vol. 41, No. 5, pp. 37–42.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Baskov, V.A., Govorkov, B.B. & Polyanskii, V.V. Cosmic-ray calibration of lead scintillation monitor with internal trigger. Bull. Lebedev Phys. Inst. 41, 140–143 (2014). https://doi.org/10.3103/S1068335614050054

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068335614050054

Keywords

Navigation