Abstract
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1′)-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 × 10−6 mol L−1 and almost theoretical Nernstian slope in the activity range 4.0 × 10−6–1 × 10−1 mol L−1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.
Similar content being viewed by others
References
I. Pais, Jr. J. Benton Jones, The Handbook of Trace Elements, (St. Lucie Press, Florida, 1997)
D. G. Barceloux, Clin. Toxicol. 37, 201 (1999)
E. Kenduzler, A.R. Turker, Int. J. Environ. An. Ch. 86, 843 (2006)
M. Felipe-Sotelo, A. Carlosena, E. Fernandez, P. Lopez-Mahia, S. Muniategui, D. Prada, Talanta 63, 735 (2004)
H. Eskandari, G.H.I. Karkaragh, Anal. Sci. 19, 1549 (2003)
M.J. Ahmed, M.N. Uddin, Chemosphere 67, 2020 (2007)
M. Korolczuk, M. Grabarczyk, A. Moroziewicz, Electroanal. 19, 2155 (2007)
P. Campins-Falco, L.A. Tortajada-Genaro, S. Meseguer-Lloret, F. Bosch-Reig, Anal. Bioanal. Chem. 374, 1223 (2002)
A.K. Jain, V.K. Gupta, L.P. Singh, U. Khurana, Analyst 122, 583 (1997)
M. Shamsipur, T. Poursaberi, S. Rouhani, K. Niknam, H. Sharghi, M.R. Ganjali, Anal. Sci. 17, 1049 (2001)
T.V. Velikanova, A.N. Titov, S.G. Mityashina, O.V. Vdovina, J. Anal. Chem. 56, 56 (2001)
S.M. Ashtamkar, N.V. Thakkar, J. Indian. Chem. Soc. 79, 90 (2002)
M.H. Mashhadizadeh, A. Moment, R. Razavi, Anal. Chim. Acta. 462, 245 (2002)
M.H. Mashhadizadeh, I. Sheikhshoaie, Anal. Bioanal. Chem. 375, 708 (2003)
M.R. Ganjali, F. Mizani, M. Emami, M. Darjezini, M.R. Darvich, M. Yousefi, Anal. Sci. 20, 531 (2004)
A.K. Singh, R.P. Singh, P. Saxena, Sensor. Actuat. B-Chem. 114, 578 (2006)
V.K. Gupta, A.K. Singh, S. Mehtab, B. Gupta, Anal. Chim. Acta. 566, 5 (2006)
J. Růžička, J.Chr. Tjell., Anal. Chim. Acta 51, 1 (1970)
V.V. Coşofreţ, P.G. Zugrăvescu, G.E. Baiulescu, Talanta 24, 461 (1977)
E. Bakker, P. Bühlman, E. Pretsch, Electroanalysis 11, 915 (1999)
G.N. Rao, S. Srivasava, S.K. Srivasava, M. Singh, Talanta 43, 1821 (1996)
P. Bühlman, E. Pretsch, E. Bakker, Chem. Rev. 98, 1593 (1998)
R. Dumkiewicz, C. Wardak, S. Zaręba, Analyst 125, 527 (2000)
R. Dumkiewicz, C. Wardak, J. Lenik, S. Zaręba, Chem. Anal. (Warsaw) 47, 257 (2002)
C. Wardak, B. Marczewska, J. Lenik, Desalination 163, 69 (2004)
C. Wardak, B. Marczewska, Chem. Anal. (Warsaw) 49, 497 (2004)
R. Dumkiewicz, K. Sykut, C. Wardak, Chem. Anal. (Warsaw) 45, 383 (2000)
S. Zaręba, Habilitation Dissertation (Medical University, Lublin, 1989)
E. Bakker E., E. Pretsch, P. Bühlman P., Anal. Chem. 72, 1127 (2000)
Y. Umezawa, K. Umezawa, H. Sato, Pure Appl. Chem. 67, 507 (1995)
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Wardak, C. Cobalt(II) ion-selective electrode with solid contact. cent.eur.j.chem. 6, 607–612 (2008). https://doi.org/10.2478/s11532-008-0060-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2478/s11532-008-0060-1