Skip to main content
Log in

Effect of Interfering Ion Concentration and Method of Calculation on Potentiometrie Selectivity Coefficients of Crown Ether Based Liquid Membrane Ion Selective Electrodes

  • Original Paper
  • Published:
Analytical Sciences Aims and scope Submit manuscript

Abstract

The Potentiometric selectivities of two 14-crown-4 ethers incorporated in PVC membrane electrodes were determined for lithium with respect to sodium and potassium in different solvents and in different carrier solutions using flow injection analysis. Four methods for calculating selectivity coefficients were compared. A correlation is made between the relative levels of the interfering ion and primary ion and the numerical values of the selectivity coefficients calculated by the different methods. An increased level of sodium causes divergence among the values of the selectivity obtained by different methods, increases the selectivity of lithium over sodium, decreases the sensitivity and the slope of the calibration graph, and distorts the linearity of the curve.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. V. P. Y. Gadzekpo and G. D. Christian, Anal. Chim. Acta, 164, 279 (1984).

    Article  CAS  Google Scholar 

  2. R. Y. Xie, V. P. Y. Gadzekpo, A. M. Kadry, Y. A. Ibrahim, J. Ruzicka and G. D. Christian, Anal. Chim. Acta, 184, 259 (1986).

    Article  CAS  Google Scholar 

  3. V. P. Y. Gadzekpo, J. M. Hungerford, A. M. Kadry, Y. A. Ibrahim, R. Y. Xie and G. D. Christian, Anal. Chem., 58, 1948 (1986).

    Article  CAS  Google Scholar 

  4. IUPAC, Pure Appl. Chem., 48, 129 (1976).

    Google Scholar 

  5. A. S. Attiyat, G. D. Christian, R. Y. Xie and R. A. Bartsch, unpublished work (1987).

  6. D. Ammann, W. E. Morf, P. Anker, P. C. Meier, E. Pretsch and W. Simon, Ion-Selective Electrode Rev., 5, 3 (1983).

    Article  CAS  Google Scholar 

  7. P. C. Meier, W. E. Morf, M. Laubli and W. Simon, Anal. Chim. Acta, 156, 1 (1984).

    Article  CAS  Google Scholar 

  8. V. P. Y. Gadzekpo, G. J. Moody, J. D. R. Thomas and G. D. Christian, Ion-Selective Electrode Rev., 8, 173 (1986).

    CAS  Google Scholar 

  9. M. Yamauchi, A. Jyo and N. Ishibashi, Anal. Chim. Acta, 136, 399 (1982).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Attiyat, A.S., Christian, G.D. Effect of Interfering Ion Concentration and Method of Calculation on Potentiometrie Selectivity Coefficients of Crown Ether Based Liquid Membrane Ion Selective Electrodes. ANAL. SCI. 4, 13–16 (1988). https://doi.org/10.2116/analsci.4.13

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.4.13

Keywords

Navigation